CoChat

Do-it-yourself in vitro vasculature that recapitulates in vivo geometries for investigating endothelial-blood cell interactions

Open access

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.

Abstract

Investigating biophysical cellular interactions in the circulation currently requires choosing between in vivo models, which are difficult to interpret due in part to the hemodynamic and geometric complexities of the vasculature; or in vitro systems, which suffer from non-physiologic assumptions and/or require specialized microfabrication facilities and expertise. To bridge that gap, we developed an in vitro “do-it-yourself” perfusable vasculature model that recapitulates in vivo geometries, such as aneurysms, stenoses and bifurcations and supports endothelial cell culture. These inexpensive, disposable devices can be created rapidly (<2 hours) with high precision and repeatability, using standard off-the-shelf laboratory supplies. Using these “endothelialized” systems, we demonstrate that spatial variation in vascular cell adhesion molecule (VCAM-1) expression correlates with the wall shear stress patterns of vascular geometries. We further observe that the presence of endothelial cells in stenoses reduces platelet adhesion but increases sickle cell disease (SCD) red blood cell (RBC) adhesion in bifurcations. Overall, our method enables researchers from all disciplines to study cellular interactions in physiologically relevant, yet simple-to-make, in vitro vasculature models.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/srep12401

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Using commonly available off-the-shelf lab supplies, “do-it yourself” (DIY) vasculature models can be created and cultured with confluent layer of endothelial cells. a) Fabrication process of the “do-it-yourself” endothelialized vasculature model. Inset in step 5 shows a confocal image of a straight fully endothelialized channel. Drawings prepared by D.R.M and R.G.M. b) Representative bright field (top) and epifluorescence (bottom) images of multiple vascular geometries including a straight channel, stenosis, aneurysm, and bifurcation. Repeatability is the standard deviation of the dimension of interest for each geometry (n = 5). Plasma membrane (Red) and cell nuclei (Blue) are fluorescently stained. Scale bar is 500 μm.
Figure 1 Using commonly available off-the-shelf lab supplies, “do-it yourself” (DIY) vasculature models can be created and cultured with confluent layer of endothelial cells. a) Fabrication process of the “do-it-yourself” endothelialized vasculature model. Inset in step 5 shows a confocal image of a straight fully endothelialized channel. Drawings prepared by D.R.M and R.G.M. b) Representative bright field (top) and epifluorescence (bottom) images of multiple vascular geometries including a straight channel, stenosis, aneurysm, and bifurcation. Repeatability is the standard deviation of the dimension of interest for each geometry (n = 5). Plasma membrane (Red) and cell nuclei (Blue) are fluorescently stained. Scale bar is 500 μm.CC BY · PubMed Central
Figure 2 Creating variations in the geometry size enables control over the wall shear stress as shown by computational fluidic dynamics analysis. Computational fluid dynamics analysis of wall shear stress within channels with varying a) degrees of stenoses, b) diameters of aneurysms, and c) angles of bifurcations. Physiologic ranges of wall shear stress are altered locally as vascular geometry is modulated. Bar graphs represent the mean wall shear stress of upwards of 100 nodes within each region of interest (i.e., spatial location where governing equations are solved in the computational domain); error bars represent standard deviation. An ANOVA (alpha = 0.05) determined that regions of interest within each geometry experience complex and significantly different wall shear stress (p < 0.000001). Post-hoc two-tailed t-tests (*P < 0.05) revealed significant differences in wall shear stress as the geometry size changes. Scale bar is 500 μm.
Figure 2 Creating variations in the geometry size enables control over the wall shear stress as shown by computational fluidic dynamics analysis. Computational fluid dynamics analysis of wall shear stress within channels with varying a) degrees of stenoses, b) diameters of aneurysms, and c) angles of bifurcations. Physiologic ranges of wall shear stress are altered locally as vascular geometry is modulated. Bar graphs represent the mean wall shear stress of upwards of 100 nodes within each region of interest (i.e., spatial location where governing equations are solved in the computational domain); error bars represent standard deviation. An ANOVA (alpha = 0.05) determined that regions of interest within each geometry experience complex and significantly different wall shear stress (p < 0.000001). Post-hoc two-tailed t-tests (*P < 0.05) revealed significant differences in wall shear stress as the geometry size changes. Scale bar is 500 μm.CC BY · PubMed Central
Figure 3 Wall shear stress regulates endothelial expression of VCAM1 in the “do-it-yourself” in vitro vasculature, while thrombomodulin expression is not altered. CFD models calculate the wall shear stress (dynes/cm2) in a) upstream control, b) aneurysm, c) stenosis, and d) bifurcation. e–h) The locations of highest levels of VCAM1 expression correspond to the areas of lowest WSS in all vascular geometries. i–l) Wall shear stress does not mediate thrombomodulin expression in the DIY in vitro vasculature. m–n) A custom image analysis script (MATLAB) quantifies the expression of VCAM1 and thrombomodulin. Each device spans a range of shear conditions, and a linear correlation with shear is present in the case of VCAM but not thrombomodulin. Scale bar is 500 μm.
Figure 3 Wall shear stress regulates endothelial expression of VCAM1 in the “do-it-yourself” in vitro vasculature, while thrombomodulin expression is not altered. CFD models calculate the wall shear stress (dynes/cm2) in a) upstream control, b) aneurysm, c) stenosis, and d) bifurcation. e–h) The locations of highest levels of VCAM1 expression correspond to the areas of lowest WSS in all vascular geometries. i–l) Wall shear stress does not mediate thrombomodulin expression in the DIY in vitro vasculature. m–n) A custom image analysis script (MATLAB) quantifies the expression of VCAM1 and thrombomodulin. Each device spans a range of shear conditions, and a linear correlation with shear is present in the case of VCAM but not thrombomodulin. Scale bar is 500 μm.CC BY · PubMed Central
Figure 4 In vascular geometries previously shown to induce platelet aggregation, the presence of cultured endothelial cells attenuates this process, highlighting the need for endothelialized in vitro vascular models. a) Platelets preferentially aggregate in a “bare” non-endothelialized stenosis at the distal end. b) No platelet aggregation is observed when the device is endothelialized. c) A custom image analysis script (MATLAB) quantifies the size of platelet aggregates in a DIY stenosis model. Traces 1–3 correspond to total platelet aggregates in boxes 1–3 shown in a–b. Scale bar is 500 μm.
Figure 4 In vascular geometries previously shown to induce platelet aggregation, the presence of cultured endothelial cells attenuates this process, highlighting the need for endothelialized in vitro vascular models. a) Platelets preferentially aggregate in a “bare” non-endothelialized stenosis at the distal end. b) No platelet aggregation is observed when the device is endothelialized. c) A custom image analysis script (MATLAB) quantifies the size of platelet aggregates in a DIY stenosis model. Traces 1–3 correspond to total platelet aggregates in boxes 1–3 shown in a–b. Scale bar is 500 μm.CC BY · PubMed Central
Figure 5 Sickle cell disease (SCD) red blood cells (RBCs) adhere and aggregate at endothelialized bifurcations. a) Control RBCs do not form aggregates in a vascular bifurcation after 275 seconds of flow. b) Relatively few SCD RBCs form small aggregates in the straight channels in the in vitro vasculature upstream of the bifurcation. c) SCD RBCs form large aggregates (arrows) at vascular bifurcations. d) A custom image analysis script (LabVIEW) quantifies the size of RBC aggregates in a region of interest (box) in a DIY bifurcation model. Control bifurcation corresponds to the box in a); SCD upstream refers to RBC aggregation in b) (box not shown for clarity); SCD bifurcation corresponds to the box in c). Scale bar is 500 μm.
Figure 5 Sickle cell disease (SCD) red blood cells (RBCs) adhere and aggregate at endothelialized bifurcations. a) Control RBCs do not form aggregates in a vascular bifurcation after 275 seconds of flow. b) Relatively few SCD RBCs form small aggregates in the straight channels in the in vitro vasculature upstream of the bifurcation. c) SCD RBCs form large aggregates (arrows) at vascular bifurcations. d) A custom image analysis script (LabVIEW) quantifies the size of RBC aggregates in a region of interest (box) in a DIY bifurcation model. Control bifurcation corresponds to the box in a); SCD upstream refers to RBC aggregation in b) (box not shown for clarity); SCD bifurcation corresponds to the box in c). Scale bar is 500 μm.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 48 references

Cited by

See all 127

Metadata

Authors
Mannino, R. G., Myers, D. R., Ahn, B., Wang, Y., Rollins, M., Gole, H., Lin, A. S., Guldberg, R. E., Giddens, D. P., Timmins, L. H., & Lam, W. A.
Affiliations
Georgia Institute of Technology (US)
Corresponding author
Lam, Wilbur A.
Venue
Scientific Reports
Published
2015-07-23
Volume
5
Issue
1
Pages
12401-12401
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2272593372
Cited by
127
References
48
Citations by year
2026: 10 · 2025: 11 · 2024: 4 · 2023: 8 · 2022: 9 · 2021: 21 · 2020: 12 · 2019: 16 · 2018: 14 · 2017: 17 · 2016: 5
FWCI
9.49
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
  • National Science Foundation (1150235, CAREER)
  • American Heart Association
  • National Institutes of Health
  • Parker H. Petit Institute for Bioengineering and Bioscience
  • National Heart, Lung, and Blood Institute (5U01-HL117721, U01HL117721, U54HL112309, R01HL121264)
Topics
  • Health Sciences › Medicine › Hematology › Blood properties and coagulation
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
Keywords
endothelial cell culture, vascular geometry, wall shear stress, VCAM-1 expression, platelet adhesion, sickle cell disease, red blood cell adhesion, aneurysm, bifurcation
MeSH terms
Blood Flow Velocity, Blood Vessels, Cell Communication, Cells, Cultured, Equipment Design, Erythrocytes, Humans, Coculture Techniques, Equipment Failure Analysis, Biomimetics, Endothelial Cells, Lab-On-A-Chip Devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.