Do-it-yourself in vitro vasculature that recapitulates in vivo geometries for investigating endothelial-blood cell interactions
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Investigating biophysical cellular interactions in the circulation currently requires choosing between in vivo models, which are difficult to interpret due in part to the hemodynamic and geometric complexities of the vasculature; or in vitro systems, which suffer from non-physiologic assumptions and/or require specialized microfabrication facilities and expertise. To bridge that gap, we developed an in vitro “do-it-yourself” perfusable vasculature model that recapitulates in vivo geometries, such as aneurysms, stenoses and bifurcations and supports endothelial cell culture. These inexpensive, disposable devices can be created rapidly (<2 hours) with high precision and repeatability, using standard off-the-shelf laboratory supplies. Using these “endothelialized” systems, we demonstrate that spatial variation in vascular cell adhesion molecule (VCAM-1) expression correlates with the wall shear stress patterns of vascular geometries. We further observe that the presence of endothelial cells in stenoses reduces platelet adhesion but increases sickle cell disease (SCD) red blood cell (RBC) adhesion in bifurcations. Overall, our method enables researchers from all disciplines to study cellular interactions in physiologically relevant, yet simple-to-make, in vitro vasculature models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Therefore, microfluidic devices (i.e. thrombosis-on-chip devices) are of interest to mimic a range of flows and shear stresses, starting from low (i.e. in veins) to high values (i.e. in arteries) [287–290].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [290]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These devices possess endothelialized lumen that can reliably capture several features of blood vessels such as atherosclerosis (i.e. fatty plaque deposition and formation) and bifurcations (i.e. branches and bends) by changing the channel geometries and flow patterns, ranging from laminar steady flow to pulsatile flow [287–290,295–304].”
From Cardiovascular disease models: A game changing paradigm in drug discovery and screening (2019) · cites this paper as [290]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Angiogenesis in cancer and other diseases
Carmeliet, P., & Jain, R. K. (2000) · Nature · doi:10.1038/35025220 · Cited by 9,070
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Ku, D. N., Giddens, D. P., Zarins, C. K., & Glagov, S. (1985) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.5.3.293 · Cited by 2,707
Self-citationSoft lithography for micro- and nanoscale patterning
Qin, D., Xia, Y., & Whitesides, G. M. (2010) · Nature Protocols · doi:10.1038/nprot.2009.234 · Cited by 2,334
Evolving functions of endothelial cells in inflammation
Pober, J. S., & Sessa, W. C. (2007) · Nature Reviews Immunology · doi:10.1038/nri2171 · Cited by 2,022
Rapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
Endothelial cell–cell junctions: happy together
Dejana, E. (2004) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1357 · Cited by 1,188
In vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894
A shear gradient–dependent platelet aggregation mechanism drives thrombus formation
Nesbitt, W. S., Westein, E., Tovar-Lopez, F. J., Tolouei, E., Mitchell, A., Fu, J., Carberry, J., Fouras, A., & Jackson, S. P. (2009) · Nature Medicine · doi:10.1038/nm.1955 · Cited by 862
Shojima, M., Oshima, M., Takagi, K., Torii, R., Hayakawa, M., Katada, K., Morita, A., & Kirino, T. (2004) · Stroke · doi:10.1161/01.str.0000144648.89172.0f · Cited by 790
Samady, H., Eshtehardi, P., McDaniel, M. C., Suo, J., Dhawan, S. S., Maynard, C., Timmins, L. H., Quyyumi, A. A., & Giddens, D. P. (2011) · Circulation · doi:10.1161/circulationaha.111.021824 · Cited by 751
Self-citationDai, G., Kaazempur-Mofrad, M. R., Natarajan, S., Zhang, Y., Vaughn, S., Blackman, B. R., Kamm, R. D., García-Cardeña, G., & Gimbrone, M. A. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406073101 · Cited by 664
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Meng, H., Wang, Z., Hoi, Y., Gao, L., Metaxa, E., Swartz, D. D., & Kolega, J. (2007) · Stroke · doi:10.1161/strokeaha.106.481234 · Cited by 606
Moake, J. L., Turner, N. A., Stathopoulos, N. A., Nolasco, L. H., & Hellums, J. D. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112736 · Cited by 599
Boussel, L., Rayz, V., McCulloch, C., Martin, A., Acevedo-Bolton, G., Lawton, M., Higashida, R., Smith, W. S., Young, W. L., & Saloner, D. (2008) · Stroke · doi:10.1161/strokeaha.108.521617 · Cited by 535
Hebbel, R. P., Boogaerts, M. A. B., Eaton, J. W., & Steinberg, M. H. (1980) · New England Journal of Medicine · doi:10.1056/nejm198005013021803 · Cited by 518
Primary role for adherent leukocytes in sickle cell vascular occlusion: A new paradigm
Turhan, A., Weiss, L. A., Mohandas, N., Coller, B. S., & Frenette, P. S. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.052522799 · Cited by 489
Correlative classification of clinical and hemodynamic function after acute myocardial infarction
Forrester, J. S., Diamond, G. A., & Swan, H. J. C. (1977) · The American Journal of Cardiology · doi:10.1016/s0002-9149(77)80182-3 · Cited by 429
Abnormal Adherence of Sickle Erythrocytes to Cultured Vascular Endothelium
Hebbel, R. P., Yamada, O., Moldow, C. F., Jacob, H. S., White, J. G., & Eaton, J. W. (1980) · Journal of Clinical Investigation · doi:10.1172/jci109646 · Cited by 423
High Wall Shear Stress and Spatial Gradients in Vascular Pathology: A Review
Dolan, J. M., Kolega, J., & Meng, H. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0695-0 · Cited by 411
Sickle cell disease: old discoveries, new concepts, and future promise
Frenette, P. S., & Atweh, G. F. (2007) · Journal of Clinical Investigation · doi:10.1172/jci30920 · Cited by 400
Nagel, T., Resnick, N., Dewey, C. F., & Gimbrone, M. A. (1999) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.19.8.1825 · Cited by 356
Effects of Disturbed Flow on Endothelial Cells
Chien, S. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9426-3 · Cited by 344
Kaul, D. K., Fabry, M. E., & Nagel, R. L. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.9.3356 · Cited by 335
Westein, E., van der Meer, A. D., Kuijpers, M. J. E., Frimat, J.-P., van den Berg, A., & Heemskerk, J. W. M. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209905110 · Cited by 304
The Biomechanics of Arterial Aneurysms
Lasheras, J. C. (2007) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.39.050905.110128 · Cited by 299
Hemodynamic Shear Stresses in Mouse Aortas: Implications for Atherogenesis
Suo, J., Ferrara, D. E., Sorescu, D., Guldberg, R. E., Taylor, W. R., & Giddens, D. P. (2007) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000253492.45717.46 · Cited by 294
Self-citationBrooks, A. R., Lelkes, P. I., & Rubanyi, G. M. (2002) · Physiological Genomics · doi:10.1152/physiolgenomics.00075.2001 · Cited by 291
Markl, M., Wegent, F., Zech, T., Bauer, S., Strecker, C., Schumacher, M., Weiller, C., Hennig, J., & Harloff, A. (2010) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.110.958504 · Cited by 232
Merkel, K. H., Ginsberg, P. L., Parker, J. C., & Post, M. J. (1978) · Stroke · doi:10.1161/01.str.9.1.45 · Cited by 216
Suresh, S. (2006) · Journal of Materials Research · doi:10.1557/jmr.2006.0260 · Cited by 186
Endothelial expression of thrombomodulin is reversibly regulated by fluid shear stress.
Malek, A. M., Jackman, R., Rosenberg, R. D., & Izumo, S. (1994) · Circulation Research · doi:10.1161/01.res.74.5.852 · Cited by 174
Barabino, G., McIntire, L., Eskin, S., Sears, D., & Udden, M. (1987) · Blood · doi:10.1182/blood.v70.1.152.152 · Cited by 165
Circulation: Cardiovascular Imaging
(2016) · Circulation Cardiovascular Imaging · doi:10.1161/hci.0000000000000011 · Cited by 156
Fluid Shear Stress Increases the Expression of Thrombomodulin by Cultured Human Endothelial Cells
Takada, Y., Shinkai, F., Kondo, S., Yamamoto, S., Tsuboi, H., Korenaga, R., & Ando, J. (1994) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.1994.2813 · Cited by 126
Neurovascular Modeling: Small-Batch Manufacturing of Silicone Vascular Replicas
Chueh, J.-Y., Wakhloo, A. K., & Gounis, M. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1543 · Cited by 106
Flow Patterns in Vessels of Simple and Complex Geometriesa
Karino, T., Goldsmith, H. L., Motomiya, M., Mabuchi, S., & Sohara, Y. (1987) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1987.tb33063.x · Cited by 96
Circulation : Cardiovascular Imaging
Editors, T. (2014) · Circulation · doi:10.1161/circulationaha.113.008014 · Cited by 82
Kalambur, V. S., Mahaseth, H., Bischof, J. C., Kielbik, M. C., Welch, T. E., Vilback, A. E., Swanlund, D. J., Hebbel, R. P., Belcher, J. D., & Vercellotti, G. M. (2004) · American Journal of Hematology · doi:10.1002/ajh.20143 · Cited by 78
Aggregate formation of erythrocytes in postcapillary venules
Kim, S., Popel, A. S., Intaglietta, M., & Johnson, P. C. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00690.2004 · Cited by 66
Farcas, M. A., Rouleau, L., Fraser, R. S., & Leask, R. L. (2009) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-8-30 · Cited by 57
Endothelialized Microfluidics for Studying Microvascular Interactions in Hematologic Diseases
Myers, D. R., Sakurai, Y., Tran, R., Ahn, B., Hardy, E. T., Mannino, R. G., Kita, A., Tsai, M., & Lam, W. A. (2012) · Journal of Visualized Experiments · doi:10.3791/3958 · Cited by 51
Self-citationTraffic of leukocytes in microfluidic channels with rectangular and rounded cross-sections
Yang, X., Forouzan, O., Burns, J. M., & Shevkoplyas, S. S. (2011) · Lab on a Chip · doi:10.1039/c1lc20293f · Cited by 48
O’Keeffe, L. M., Muir, G., Piterina, A. V., & McGloughlin, T. M. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.3148191 · Cited by 46
Development of a flow-through system to create occluding thrombus
Ku, D. N., & Flannery, C. J. (2007) · Biorheology · doi:10.1177/0006355x2007044004003 · Cited by 36
Arteriosclerosis, Thrombosis, and Vascular Biology , 2005
Heistad, D. D. (2005) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.0000151931.91737.00 · Cited by 28
Computational fluid dynamics of aggregating red blood cells in postcapillary venules
Chung, B., Kim, S., Johnson, P. C., & Popel, A. S. (2009) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840802624718 · Cited by 6
Cited by
Costa, P. F., Albers, H. J., Linssen, J. E. A., Middelkamp, H. H. T., van der Hout, L., Passier, R., van den Berg, A., Malda, J., & van der Meer, A. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00202e · Cited by 226
Cardiovascular disease models: A game changing paradigm in drug discovery and screening
Savoji, H., Mohammadi, M. H., Rafatian, N., Toroghi, M. K., Wang, E. Y., Zhao, Y., Korolj, A., Ahadian, S., & Radisic, M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.036 · Cited by 223
Cochrane, A., Albers, H. J., Passier, R., Mummery, C. L., van den Berg, A., Orlova, V. V., & van der Meer, A. D. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.06.007 · Cited by 162
Zhou, G., Zhu, Y., Yin, Y., Su, M., & Li, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-05886-w · Cited by 122
In Vitro Strategies to Vascularize 3D Physiologically Relevant Models
Dellaquila, A., Le Bao, C., Letourneur, D., & Simon‐Yarza, T. (2021) · Advanced Science · doi:10.1002/advs.202100798 · Cited by 115
Metadata
- Authors
- Mannino, R. G., Myers, D. R., Ahn, B., Wang, Y., Rollins, M., Gole, H., Lin, A. S., Guldberg, R. E., Giddens, D. P., Timmins, L. H., & Lam, W. A.
- Affiliations
- Georgia Institute of Technology (US)
- Corresponding author
- Lam, Wilbur A.
- ORCID
- Venue
- Scientific Reports
- Published
- 2015-07-23
- Volume
- 5
- Issue
- 1
- Pages
- 12401-12401
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC4894411
- OpenAlex
- W2272593372
- Cited by
- 127
- References
- 48
- Citations by year
- 2026: 10 · 2025: 11 · 2024: 4 · 2023: 8 · 2022: 9 · 2021: 21 · 2020: 12 · 2019: 16 · 2018: 14 · 2017: 17 · 2016: 5
- FWCI
- 9.49
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (1150235, CAREER)
- American Heart Association
- National Institutes of Health
- Parker H. Petit Institute for Bioengineering and Bioscience
- National Heart, Lung, and Blood Institute (5U01-HL117721, U01HL117721, U54HL112309, R01HL121264)
- Topics
- Health Sciences › Medicine › Hematology › Blood properties and coagulation
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Cell Biology › Cellular Mechanics and Interactions
- Keywords
- endothelial cell culture, vascular geometry, wall shear stress, VCAM-1 expression, platelet adhesion, sickle cell disease, red blood cell adhesion, aneurysm, bifurcation
- MeSH terms
- Blood Flow Velocity, Blood Vessels, Cell Communication, Cells, Cultured, Equipment Design, Erythrocytes, Humans, Coculture Techniques, Equipment Failure Analysis, Biomimetics, Endothelial Cells, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.