A spheroid toxicity assay using magnetic 3D bioprinting and real-time mobile device-based imaging
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
An ongoing challenge in biomedical research is the search for simple, yet robust assays using 3D cell cultures for toxicity screening. This study addresses that challenge with a novel spheroid assay, wherein spheroids, formed by magnetic 3D bioprinting, contract immediately as cells rearrange and compact the spheroid in relation to viability and cytoskeletal organization. Thus, spheroid size can be used as a simple metric for toxicity. The goal of this study was to validate spheroid contraction as a cytotoxic endpoint using 3T3 fibroblasts in response to 5 toxic compounds (all-trans retinoic acid, dexamethasone, doxorubicin, 5′-fluorouracil, forskolin), sodium dodecyl sulfate (+control) and penicillin-G (−control). Real-time imaging was performed with a mobile device to increase throughput and efficiency. All compounds but penicillin-G significantly slowed contraction in a dose-dependent manner (Z’ = 0.88). Cells in 3D were more resistant to toxicity than cells in 2D, whose toxicity was measured by the MTT assay. Fluorescent staining and gene expression profiling of spheroids confirmed these findings. The results of this study validate spheroid contraction within this assay as an easy, biologically relevant endpoint for high-throughput compound screening in representative 3D environments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, J.-H., Chung, T. D. Y., & Oldenburg, K. R. (1999) · SLAS Discovery · doi:10.1177/108705719900400206 · Cited by 6,847
Differential analysis of gene regulation at transcript resolution with RNA-seq
Trapnell, C., Hendrickson, D. G., Sauvageau, M., Goff, L., Rinn, J. L., & Pachter, L. (2013) · Nature Biotechnology · doi:10.1038/nbt.2450 · Cited by 3,492
Taking Cell-Matrix Adhesions to the Third Dimension
Cukierman, E., Pankov, R., Stevens, D. R., & Yamada, K. M. (2001) · Science · doi:10.1126/science.1064829 · Cited by 3,027
The third dimension bridges the gap between cell culture and live tissue
Pampaloni, F., Reynaud, E. G., & Stelzer, E. H. K. (2007) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2236 · Cited by 2,817
Spheroid-based drug screen: Considerations and practical approach
Friedrich, J., Seidel, C., Ebner, R., & Kunz-Schughart, L. A. (2009) · Nature Protocols · doi:10.1038/nprot.2008.226 · Cited by 1,742
Multicellular tumor spheroids: An underestimated tool is catching up again
Hirschhaeuser, F., Menne, H., Dittfeld, C., West, J., Mueller-Klieser, W., & Kunz-Schughart, L. A. (2010) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2010.01.012 · Cited by 1,674
Gene expression regulation by retinoic acid
Balmer, J. E., & Blomhoff, R. (2002) · Journal of Lipid Research · doi:10.1194/jlr.r100015-jlr200 · Cited by 1,039
Vinci, M., Gowan, S., Boxall, F., Patterson, L., Zimmermann, M., Court, W., Lomas, C., Mendiola, M., Hardisson, D., & Eccles, S. A. (2012) · BMC Biology · doi:10.1186/1741-7007-10-29 · Cited by 1,024
High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array
Tung, Y.-C., Hsiao, A. Y., Allen, S. G., Torisawa, Y.-S., Ho, M., & Takayama, S. (2011) · The Analyst · doi:10.1039/c0an00609b · Cited by 969
Three-Dimensional In Vitro Co-Culture Model of Breast Tumor using Magnetic Levitation
Jaganathan, H., Gage, J., Leonard, F., Srinivasan, S., Souza, G. R., Dave, B., & Godin, B. (2014) · Scientific Reports · doi:10.1038/srep06468 · Cited by 231
Self-citationGlucocorticoid regulation of beta-adrenergic receptors in 3T3-L1 preadipocytes.
Nakada, M. T., Stadel, J. M., Poksay, K. S., & Crooke, S. T. (1987) · Molecular Pharmacology · doi:10.1016/s0026-895x(25)10446-x · Cited by 78 · cited 1×
“…IC50 (μM) Endpoint Rate of contraction over 150 min Viability at 72 h ATRA 82.8 24.7 20 (Seiler et al., 2011)16 Dexamethasone 84.6 n.s. 2.77 × 10 −3 (Nakada et al., 1987)45 Doxorubicin 46.7 12.7 0.33 (NIEHS Registry of Cytotoxicity)35 5′ -fluorouracil 253 n.s. 2.6 (NIEHS Registry of…”
Influential
Cited by
Progress in 3D bioprinting technology for tissue/organ regenerative engineering
Matai, I., Kaur, G., Seyedsalehi, A., McClinton, A., & Laurencin, C. T. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2019.119536 · Cited by 1,156
Three-dimensional culture systems in cancer research: Focus on tumor spheroid model
Nath, S., & Devi, G. R. (2016) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2016.03.013 · Cited by 919
Bio-inks for 3D bioprinting: recent advances and future prospects
Donderwinkel, I., van Hest, J. C. M., & Cameron, N. R. (2017) · Polymer Chemistry · doi:10.1039/c7py00826k · Cited by 378
Principles of the Kenzan Method for Robotic Cell Spheroid-Based Three-Dimensional Bioprinting
Moldovan, N. I., Hibino, N., & Nakayama, K. (2017) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2016.0322 · Cited by 296
Barbosa, M. A. G., Xavier, C. P. R., Pereira, R. F., Petrikaitė, V., & Vasconcelos, M. H. (2021) · Cancers · doi:10.3390/cancers14010190 · Cited by 285
“Unfortunately, regarding the scaffold-free techniques readout, it is particularly difficult to visualize spheroids on round-bottom plates and on hanging drops [75].”
Background
Metadata
- Authors
- Tseng, H., Gage, J. A., Shen, T., Haisler, W. L., Neeley, S. K., Shiao, S., Chen, J., Desai, P. K., Liao, A., Hebel, C., Raphael, R. M., Becker, J. L., & Souza, G. R.
- Venue
- Scientific Reports
- Published
- 2015-09-14
- Volume
- 5
- Issue
- 1
- Pages
- 13987-13987
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2411123878
- Cited by
- 148
- References
- 11
- FWCI
- 6.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.