CoChat

Point-of-need diagnosis of cystic fibrosis using a potentiometric ion-selective electrode array

Lynch, Aogán, Diamond, Dermot, Leader, Matt · 2000 · The Analyst
Cited by 59

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The novel approach of using a micro-sensor array of miniaturised solid-state ion-selective electrodes to analyse sweat samples for sodium, potassium and chloride simultaneously is described. The array, incorporated into a miniature flow cell which is linked to a portable PC for data acquisition, constitutes a small, portable, and simple to use analytical instrument. Samples are passed through the flow cell and over the array and an immediate potentiometric response is obtained, which can be equated to the concentrations of sodium, chloride, potassium and other parameters in the sweat sample. Used here in conjunction with a Wescor Macroduct sweat sampling unit, it promises a much simplified, much less expensive procedure for sweat analysis than the procedures currently in common use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b006379g

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 59

Metadata

Authors
Lynch, A., Diamond, D., & Leader, M.
Venue
The Analyst
Published
2000
Volume
125
Issue
12
Pages
2264-2267
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W1985449716
Cited by
59
References
1
FWCI
0.61
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Point-of-need diagnosis of cystic fibrosis using a potentiometric ion-selective electrode array. https://app.cochat.ai/papers/10.1039/b006379g
The paper
Lynch, A., Diamond, D., & Leader, M. (2000). Point-of-need diagnosis of cystic fibrosis using a potentiometric ion-selective electrode array. The Analyst. https://doi.org/10.1039/b006379g

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.