The DOI matches its Crossref record.
Enzyme linked immunosorbent assay on a microchip with electrochemical detection
Open accessAbstract
This paper presents the development of a sandwich immunoassay in disposable plastic microchips. Photoablated microchannels with integrated electrodes have been used for the development of enzyme-linked-immunosorbent-assay (ELISA). The presence of the electrode inside the 40 nL microchannel enables the detection of the redox active enzyme substrate directly inside the reaction channel. Furthermore, due to the small diffusion distances, each incubation time can be reduced to five minutes instead of a few hours in standard microtiterplates. The initial characterisation of this immunoassay has been performed with a large protein complex D-Dimer-alkaline phosphatase. This system was used for the detection of immobilised antibodies on the surface of the photoablated microchannel. In a second step, a sandwich immunoassay with a horseradish peroxidase-secondary antibody conjugate (HRP-conjugate) was used to detect D-Dimer between 0.1 and 100 nM, which is the relevant concentration range of the clinical tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Verpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
Design of a Compact Disk-like Microfluidic Platform for Enzyme-Linked Immunosorbent Assay
Lai, S., Wang, S., Luo, J., Lee, L. J., Yang, S.-T., & Madou, M. J. (2004) · Analytical Chemistry · doi:10.1021/ac0348322 · Cited by 418
Microfluidics: Applications for analytical purposes in chemistry and biochemistry
Ohno, K., Tachikawa, K., & Manz, A. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200800121 · Cited by 398
Microfluidic systems in proteomics
Lion, N., Rohner, T. C., Dayon, L., Arnaud, I. L., Damoc, E., Youhnovski, N., Wu, Z., Roussel, C., Josserand, J., Jensen, H., et al. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305629 · Cited by 262
Self-citation
Metadata
- Authors
- Rossier, J. S., & Girault, H. H.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2001
- Volume
- 1
- Issue
- 2
- Pages
- 153
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2031610738
- Cited by
- 164
- References
- 0
- FWCI
- 7.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enzyme linked immunosorbent assay on a microchip with electrochemical detection. https://app.cochat.ai/papers/10.1039/b104772h
- The paper
- Rossier, J. S., & Girault, H. H. (2001). Enzyme linked immunosorbent assay on a microchip with electrochemical detection. Lab on a Chip. https://doi.org/10.1039/b104772h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.