Fluorescent nano-PEBBLE sensors designed for intracellular glucose imaging
The DOI matches its Crossref record.
Abstract
Polyacrylamide-based, ratiometric, spherical, optical nanosensors, or polyacrylamide PEBBLEs (Probes Encapsulated By Biologically Localized Embedding), have been fabricated, aimed at real-time glucose imaging in intact biological systems, i.e. living cells. These nanosensors are prepared using a microemulsion polymerization process, and their average size is about 45 nm in diameter. The sensors incorporate glucose oxidase (GOx), an oxygen sensitive fluorescent indicator (Ru[dpp(SO3Na)2]3)Cl2, and an oxygen insensitive fluorescent dye, Oregon Green 488-dextran or Texas Red-dextran, as a reference for the purpose of ratiometric intensity measurements. The enzymatic oxidation of glucose to gluconic acid results in the local depletion of oxygen, which is measured by the oxygen sensitive ruthenium dye. The small size and inert matrix of these sensors allows them to be inserted into living cells with minimal physical and chemical perturbations to their biological functions. The PEBBLE matrix protects the enzyme and fluorescent dyes from interference by proteins in cells, enabling reliable in vivo chemical analysis. Conversely, the matrix also significantly reduces the toxicity of the indicator and reference dyes to the cells, so that a larger variety of dyes can be used in optimal fashion. Furthermore, the PEBBLE matrix enables the synergistic approach in which there is a steady state of local oxygen consumption, and this cannot be achieved by separately introducing free enzyme and dyes into a cell. The work presented here describes the production and characterization of glucose sensitive PEBBLEs, and their potential for intracellular glucose measurements. The sensor response is determined in terms of the linear range, ratiometric operation, response time, sensor stability, reversibility and immunity to interferences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Borisov, S. M., & Wolfbeis, O. S. (2008) · Chemical Reviews · doi:10.1021/cr068105t · Cited by 1,018
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
Optical methods for sensing glucose
Steiner, M.-S., Duerkop, A., & Wolfbeis, O. S. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15063d · Cited by 497
Brain cancer diagnosis and therapy with nanoplatforms☆
KOO, Y., REDDY, G., BHOJANI, M., SCHNEIDER, R., PHILBERT, M., REHEMTULLA, A., ROSS, B., & KOPELMAN, R. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.012 · Cited by 326
Self-citationFluorescent nanoparticles for intracellular sensing: A review
Ruedas-Rama, M. J., Walters, J. D., Orte, A., & Hall, E. A. H. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.09.025 · Cited by 321
Glucose oxidase?magnetite nanoparticle bioconjugate for glucose sensing
Rossi, L. M., Quach, A. D., & Rosenzweig, Z. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2770-3 · Cited by 314
Zheng, G., Chen, J., Li, H., & Glickson, J. D. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508677102 · Cited by 226
Fluorescence Glucose Detection: Advances Toward the Ideal In Vivo Biosensor
Moschou, E. A., Sharma, B. V., Deo, S. K., & Daunert, S. (2004) · Journal of Fluorescence · doi:10.1023/b:jofl.0000039341.64999.83 · Cited by 154
Metadata
- Authors
- Xu, H., Aylott, J. W., & Kopelman, R.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2002-09-27
- Volume
- 127
- Issue
- 11
- Pages
- 1471-1477
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2150531140
- Cited by
- 144
- References
- 0
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.