Determination of trace elements in pumpkin seed oils and pumpkin seeds by ICP-AES
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Inductively coupled plasma atomic emission spectrometry (ICP-AES) was used for the determination of the elements present in pumpkin seed oil and pumpkin seeds. After extraction of the oil from pumpkin seeds a residue was obtained. For the determination of elements three types of samples were used: oil, seeds and the residue (after oil extraction). Three different digestion types were applied: open vessel and closed vessel digestion in a steel bomb as well as microwave digestion in a closed system. For most elements of interest the measured concentration differs depending on the digestion method used. After microwave digestion a good reproducibility for ICP-AES measurements for all elements was found. Determination of Zn by ICP-AES is possible both after open and closed vessel digestion (steel bomb or microwave digestion). No loss of volatile compounds in pumpkin oil during preparation or microwave digestion prior to ICP-AES analysis could be observed. In general, the recoveries for all elements in pumpkin seed oils and seeds were >95%, for S only they were <50%. Differences in the element concentration were found for seed oil obtained from the same seeds but prepared by two different procedures, extracted by Soxhlet and commercially produced after roasting of the seeds. The differences of the measured element concentrations after application of different types of dissolution procedures are discussed. The closed vessel dissolution was found to be the best procedure prior to the ICP-AES determination of metals. The method is evaluated by application of the standard addition method and by recovery experiments. Addition of salt during the oil production procedure causes approx. 10 times the Ca, K, Mg, and Na amounts compared to the Soxhlet extracted oil produced in the laboratory. Higher amounts of Na could be registered in the residues as well. The LODs were <0.1 µg g−1 for Ca, Cd, Mg, Mn, Ti, and Zn, in the range of 0.1 to 0.8 µg g−1 for Co, Cu, Fe, K, Mo, Na, Ni, Pb, and V, and >0.8 µg g−1 for Al, Cr and P in pumpkin oil samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Karadjova, I., Zachariadis, G., Boskou, G., & Stratis, J. (1998) · Journal of Analytical Atomic Spectrometry · doi:10.1039/a707256b · Cited by 97
Cited by
Karimi, M., Dadfarnia, S., Shabani, A. M. H., Tamaddon, F., & Azadi, D. (2015) · Talanta · doi:10.1016/j.talanta.2015.07.021 · Cited by 182
GLEW, R. H., GLEW, R. S., CHUANG, L.-T., HUANG, Y.-S., MILLSON, M., CONSTANS, D., & VANDERJAGT, D. J. (2006) · Plant Foods for Human Nutrition · doi:10.1007/s11130-006-0010-z · Cited by 177
Lepri, F. G., Chaves, E. S., Vieira, M. A., Ribeiro, A. S., Curtius, A. J., DeOliveira, L. C. C., & DeCampos, R. C. (2011) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2010.529628 · Cited by 119
“determined trace elements in pumpkin seed oil and pumpkin seeds by ICP-OES after wet digestion using a mixture of HNO3 and H2O2 and compared three different digestion procedures: open and closed vessels in a steel bomb as well as microwaveassisted digestion in a closed system (38).”
MethodLópez-García, I., Vicente-Martínez, Y., & Hernández-Córdoba, M. (2014) · Talanta · doi:10.1016/j.talanta.2014.02.011 · Cited by 87
Matos Reyes, M. N., & Campos, R. C. (2006) · Talanta · doi:10.1016/j.talanta.2006.05.055 · Cited by 79
Metadata
- Authors
- Juranovic, I., Breinhoelder, P., & Steffan, I.
- Venue
- Journal of Analytical Atomic Spectrometry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2002-12-11
- Volume
- 18
- Issue
- 1
- Pages
- 54-58
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2128995501
- Cited by
- 65
- References
- 1
- FWCI
- 0.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.