The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
An integrated AC electrokinetic pump in a microfluidic loop for fast and tunable flow control
Abstract
We have built a dedicated lab on a chip to study the performance of an integrated electrokinetic micropump, driven by a low voltage AC signal. This micropump consists of an array of interdigitated electrodes and is here integrated in a microfluidic loop. We demonstrate that this device can pump continuously and reproducibly electrolyte solutions of low to moderate ionic strength. The pumping speed reaches up to 500 [micro sign]m s(-1) in 20 [micro sign]m deep and 100 [micro sign]m wide channels with a driving signal in the 1-10 kHz range and an amplitude of only a few volts. In addition, we have observed an interesting reversal of the pumping direction at higher frequencies (50-100 kHz). Our device permits a systematic and automated exploration of the influence of the ionic strength thanks to an integrated micromixer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Self-citationParticle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Laser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
A particle image velocimetry system for microfluidics
Santiago, J. G., Wereley, S. T., Meinhart, C. D., Beebe, D. J., & Adrian, R. J. (1998) · Experiments in Fluids · doi:10.1007/s003480050235 · Cited by 1,174
Induced-charge electro-osmosis
SQUIRES, T. M., & BAZANT, M. Z. (2004) · Journal of Fluid Mechanics · doi:10.1017/s0022112004009309 · Cited by 716
AC Electric-Field-Induced Fluid Flow in Microelectrodes
Ramos, A., Morgan, H., Green, N. G., & Castellanos, A. (1999) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1999.6346 · Cited by 527
Hansen, C. L., Skordalakes, E., Berger, J. M., & Quake, S. R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.262485199 · Cited by 517
2004 Induced-charge electro-osmosis
Squires, T. M., Martin, & Bazant, Z. (2003) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 513
A nanoliter-scale nucleic acid processor with parallel architecture
Hong, J. W., Studer, V., Hang, G., Anderson, W. F., & Quake, S. R. (2004) · Nature Biotechnology · doi:10.1038/nbt951 · Cited by 470
Self-citationPumping of liquids with ac voltages applied to asymmetric pairs of microelectrodes
Ramos, A., González, A., Castellanos, A., Green, N. G., & Morgan, H. (2003) · Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics · doi:10.1103/physreve.67.056302 · Cited by 248
Chou, H.-P., Unger, M. A., & Quake, S. R. (2001) · Biomedical Microdevices · doi:10.1023/a:1012412916446 · Cited by 223
Particle Tracking Techniques for Electrokinetic Microchannel Flows
Devasenathipathy, S., Santiago, J. G., & Takehara, K. (2002) · Analytical Chemistry · doi:10.1021/ac011243s · Cited by 141
Cited by
Integrated optofluidics: A new river of light
Monat, C., Domachuk, P., & Eggleton, B. J. (2007) · Nature Photonics · doi:10.1038/nphoton.2006.96 · Cited by 955
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Bazant, M. Z., Kilic, M. S., Storey, B. D., & Ajdari, A. (2009) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2009.10.001 · Cited by 916
Self-citationElectroosmotic pumps and their applications in microfluidic systems
Wang, X., Cheng, C., Wang, S., & Liu, S. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0399-9 · Cited by 343
Remotely powered self-propelling particles and micropumps based on miniature diodes
Chang, S. T., Paunov, V. N., Petsev, D. N., & Velev, O. D. (2007) · Nature Materials · doi:10.1038/nmat1843 · Cited by 314
Metadata
- Authors
- Studer, V., Pépin, A., Chen, Y., & Ajdari, A.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 129
- Issue
- 10
- Pages
- 944-949
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2099050658
- Cited by
- 290
- References
- 14
- FWCI
- 13.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.