Development of an integrated microfluidic platform for dynamic oxygen sensing and delivery in a flowing medium
The DOI matches its Crossref record.
Abstract
This paper describes a platform for real-time sensing of dissolved oxygen in a flowing microfluidic environment using an oxygen-sensitive luminescent dye (platinum octaethylporphyrin ketone) integrated into a micro-oxygenator device. Using a phase-based detection method, the luminescent decay lifetime of the dye was consistent with the linear Stern-Volmer relationship using both gaseous and aqueous samples. Maximum sensor resolution varied between 120-780 ppb across a range of dissolved oxygen (DO) concentrations ranging from 0-42.5 ppm. The sensor was subsequently used to determine the convective mass-transfer characteristics of a multi-layer polydimethylsiloxane (PDMS) microfluidic oxygenator. The membrane-based oxygenator showed excellent agreement with an analytical convection model, and the integrated oxygen sensor was accurate across a wide range of tested flow rates (0.05-5 mL min(-1)). The device is unique for its ease of fabrication and highly flexible configuration, as well as the novel incorporation of oxygen delivery and detection in a single micro-device. Potential applications include tissue engineering, cell culturing, and miniaturized bio-assays that require the delivery and/or detection of precise quantities of oxygen within a microfluidic construct.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vascularization Strategies for Tissue Engineering
Lovett, M., Lee, K., Edwards, A., & Kaplan, D. L. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0085 · Cited by 923
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Membranes and microfluidics: a review
de Jong, J., Lammertink, R. G. H., & Wessling, M. (2006) · Lab on a Chip · doi:10.1039/b603275c · Cited by 483
Oxygen control with microfluidics
Brennan, M. D., Rexius-Hall, M. L., Elgass, L. J., & Eddington, D. T. (2014) · Lab Chip · doi:10.1039/c4lc00853g · Cited by 188
Methods to study the tumor microenvironment under controlled oxygen conditions
Byrne, M. B., Leslie, M. T., Gaskins, H. R., & Kenis, P. J. A. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.09.006 · Cited by 104
High-throughput analysis of signals regulating stem cell fate and function
Underhill, G. H., & Bhatia, S. N. (2007) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2007.05.036 · Cited by 93
“Independent of flow rate, microfluidic systems have also been used to generate culture models exhibiting a range of oxygen concentrations [41], as well as growth factor and chemotactic gradients [42,43].”
MethodRivera, K. R., Yokus, M. A., Erb, P. D., Pozdin, V. A., & Daniele, M. (2019) · The Analyst · doi:10.1039/c8an02201a · Cited by 57
Metadata
- Authors
- Vollmer, A. P., Probstein, R. F., Gilbert, R., & Thorsen, T.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2005
- Volume
- 5
- Issue
- 10
- Pages
- 1059
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2006835321
- Cited by
- 140
- References
- 0
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.