The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Development and multiplexed control of latching pneumatic valves using microfluidic logical structures
Abstract
Novel latching microfluidic valve structures are developed, characterized, and controlled independently using an on-chip pneumatic demultiplexer. These structures are based on pneumatic monolithic membrane valves and depend upon their normally-closed nature. Latching valves consisting of both three- and four-valve circuits are demonstrated. Vacuum or pressure pulses as short as 120 ms are adequate to hold these latching valves open or closed for several minutes. In addition, an on-chip demultiplexer is demonstrated that requires only n pneumatic inputs to control 2(n-1) independent latching valves. These structures can reduce the size, power consumption, and cost of microfluidic analysis devices by decreasing the number of off-chip controllers. Since these valve assemblies can form the standard logic gates familiar in electronic circuit design, they should be useful in developing complex pneumatic circuits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Numerical recipes in Pascal: the art of scientific computing
(1990) · Choice Reviews Online · doi:10.5860/choice.27-5158 · Cited by 11,811
Numerical Recipes in C: The Art of Scientific Computing.
Birchenhall, C., Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · The Economic Journal · doi:10.2307/2234664 · Cited by 4,355
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Grover, W. H., Skelley, A. M., Liu, C. N., Lagally, E. T., & Mathies, R. A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00468-9 · Cited by 517
Self-citationEmrich, C. A., Tian, H., Medintz, I. L., & Mathies, R. A. (2002) · Analytical Chemistry · doi:10.1021/ac020236g · Cited by 284
Self-citationMicrofabricated bioprocessor for integrated nanoliter-scale Sanger DNA sequencing
Blazej, R. G., Kumaresan, P., & Mathies, R. A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602476103 · Cited by 277
Self-citationDevelopment and evaluation of a microdevice for amino acid biomarker detection and analysis on Mars
Skelley, A. M., Scherer, J. R., Aubrey, A. D., Grover, W. H., Ivester, R. H. C., Ehrenfreund, P., Grunthaner, F. J., Bada, J. L., & Mathies, R. A. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406798102 · Cited by 262
Self-citation
Cited by
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Micro Total Analysis Systems: Latest Achievements
West, J., Becker, M., Tombrink, S., & Manz, A. (2008) · Analytical Chemistry · doi:10.1021/ac800680j · Cited by 423
Microfluidics: Innovations in Materials and Their Fabrication and Functionalization
Nielsen, J. B., Hanson, R. L., Almughamsi, H. M., Pang, C., Fish, T. R., & Woolley, A. T. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b04986 · Cited by 359
Metadata
- Authors
- Grover, W. H., Ivester, R. H. C., Jensen, E. C., & Mathies, R. A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 6
- Issue
- 5
- Pages
- 623
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1990521360
- Cited by
- 253
- References
- 13
- FWCI
- 11.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development and multiplexed control of latching pneumatic valves using microfluidic logical structures. https://app.cochat.ai/papers/10.1039/b518362f
- The paper
- Grover, W. H., Ivester, R. H. C., Jensen, E. C., & Mathies, R. A. (2006). Development and multiplexed control of latching pneumatic valves using microfluidic logical structures. Lab on a Chip. https://doi.org/10.1039/b518362f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.