The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Chip integrated strategies for acoustic separation and manipulation of cells and particles
Abstract
Acoustic standing wave technology combined with microtechnology opens up new areas for the development of advanced particle and cell separating microfluidic systems. This tutorial review outlines the fundamental work performed on continuous flow acoustic standing wave separation of particles in macro scale systems. The transition to the microchip format is further surveyed, where both fabrication and design issues are discussed. The acoustic technology offers attractive features, such as reasonable throughput and ability to separate particles in a size domain of about tenths of micrometers to tens of micrometers. Examples of different particle separation modes enabled in microfluidic chips, utilizing standing wave technology, are described along a discussion of several potential applications in life science research and in the medical clinic. Chip integrated acoustic standing wave separation technology is still in its infancy and it can be anticipated that new laboratory standards very well may emerge from the current research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1995) · Springer eBooks · doi:10.1007/978-94-011-0161-5 · Cited by 1,250
Field-Flow Fractionation: Analysis of Macromolecular, Colloidal, and Particulate Materials
Giddings, J. C. (1993) · Science · doi:10.1126/science.8502990 · Cited by 1,141
Acoustic radiation pressure on a compressible sphere
Yosioka, K. (1955) · Acustica · Cited by 726
Journal of Statistical Mechanics: Theory and Experiment
(2015) · Journal of Statistical Mechanics Theory and Experiment · doi:10.1088/1742-5468 · Cited by 514
Petersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T. (2005) · Lab Chip · doi:10.1039/b405748c · Cited by 360
Self-citationSeparation of lipids from blood utilizing ultrasonic standing waves in microfluidic channels
Petersson, F., Nilsson, A., Holm, C., Jönsson, H., & Laurell, T. (2004) · The Analyst · doi:10.1039/b409139f · Cited by 330
Self-citationDefining neuropsychological dysfunction after coronary artery bypass grafting
Mahanna, E. P., Blumenthal, J. A., White, W. D., Croughwell, N. D., Clancy, C. P., Richard Smith, L., & Newman, M. F. (1996) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)01095-5 · Cited by 258
A 3-D microelectrode system for handling and caging single cells and particles
Müller, T., Gradl, G., Howitz, S., Shirley, S., Schnelle, T., & Fuhr, G. (1999) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00006-8 · Cited by 242
Esashi, M. (1998) · International Microprocesses and Nanotechnology Conference (MNC) · doi:10.1109/imnc.1998.729908 · Cited by 230
Moody, D. M., Brown, W. R., Challa, V. R., Stump, D. A., Reboussin, D. M., & Legault, C. (1995) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)00057-r · Cited by 199
Carrier Medium Exchange through Ultrasonic Particle Switching in Microfluidic Channels
Petersson, F., Nilsson, A., Jönsson, H., & Laurell, T. (2005) · Analytical Chemistry · doi:10.1021/ac048394q · Cited by 163
Self-citationAcoustic Cell Filter for High Density Perfusion Culture of Hybridoma Cells
TRAMPLER, F., Sonderhoff, S. A., Pui, P. W. S., Kilburn, D. G., & Piret, J. M. (1994) · Nature Biotechnology · doi:10.1038/nbt0394-281 · Cited by 147
A silicon microfluidic ultrasonic separator
Harris, N. R., Hill, M., Beeby, S., Shen, Y., White, N. M., Hawkes, J. J., & Coakley, W. T. (2003) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(03)00448-9 · Cited by 144
Bazou, D., Kuznetsova, L. A., & Coakley, W. T. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.12.007 · Cited by 95
Johnson, D. A., & Feke, D. L. (1995) · Separations Technology · doi:10.1016/0956-9618(95)00130-1 · Cited by 91
Pui, P. W. S., TRAMPLER, F., Sonderhoff, S. A., Gröschl, M., Kilburn, D. G., & Piret, J. M. (1995) · Biotechnology Progress · doi:10.1021/bp00032a005 · Cited by 85
Gupta, S., Feke, D. L., & Manas‐Zloczower, I. (1995) · Chemical Engineering Science · doi:10.1016/0009-2509(95)00154-w · Cited by 77
Fractionation of cell mixtures using acoustic and laminar flow fields
Kumar, M., Feke, D. L., & Belovich, J. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.20294 · Cited by 57
Böhm, H. R., BRIARTY, L. G., Lowe, K. C., Power, J. B., BENES, E., & Davey, M. R. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10546 · Cited by 39
Cited by
Lanthanide Luminescence for Biomedical Analyses and Imaging
Bünzli, J.-C. G. (2010) · Chemical Reviews · doi:10.1021/cr900362e · Cited by 2,690
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Guidelines for the use of flow cytometry and cell sorting in immunological studies (second edition)
Cossarizza, A., Chang, H., Radbruch, A., Acs, A., Adam, D., Adam‐Klages, S., Agace, W. W., Aghaeepour, N., Akdis, M., Allez, M., et al. (2019) · European Journal of Immunology · doi:10.1002/eji.201970107 · Cited by 979
Metadata
- Authors
- Laurell, T., Petersson, F., & Nilsson, A.
- Venue
- Chem. Soc. Rev.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 36
- Issue
- 3
- Pages
- 492-506
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2116649306
- Cited by
- 874
- References
- 19
- FWCI
- 1.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.