The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
High-performance flow-focusing geometry for spontaneous generation of monodispersed droplets
Abstract
A high-performance flow-focusing geometry for spontaneous generation of monodispersed droplets is demonstrated. In this geometry, a two-phase flow is forced through a circular orifice integrated inside a silicon-based microchannel. The orifice with its cusp-like edge exerts a ring of maximized stress around the flow and ensures controlled breakup of droplets for a wide range of flow rates, forming highly periodic and reproducible dispersions. The droplet generation can be remarkably rapid, exceeding 10(4) s(-1) for water-in-oil droplets and reaching 10(3) s(-1) for oil-in-water droplets, being largely controlled by flow rate of the continuous phase. The droplet diameter and generation frequency are compared against a quasi-equilibrium model based on the critical Capillary number. The droplets are obtained despite the low Capillary number, below the critical value identified by the ratio of viscosities between the two phases and simple shear-flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Monodisperse Double Emulsions Generated from a Microcapillary Device
Utada, A. S., Lorenceau, E., Link, D. R., Kaplan, P. D., Stone, H. A., & Weitz, D. A. (2005) · Science · doi:10.1126/science.1109164 · Cited by 2,248
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
GRACE†, H. P. (1982) · Chemical Engineering Communications · doi:10.1080/00986448208911047 · Cited by 1,497
Understanding foods as soft materials
Mezzenga, R., Schurtenberger, P., Burbidge, A., & Michel, M. (2005) · Nature Materials · doi:10.1038/nmat1496 · Cited by 687
Formation of monodisperse bubbles in a microfluidic flow-focusing device
Garstecki, P., Gitlin, I., DiLuzio, W., Whitesides, G. M., Kumacheva, E., & Stone, H. A. (2004) · Applied Physics Letters · doi:10.1063/1.1796526 · Cited by 641
Perfectly Monodisperse Microbubbling by Capillary Flow Focusing
Gañán-Calvo, A. M., & Gordillo, J. M. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.274501 · Cited by 587
Shestopalov, I., Tice, J. D., & Ismagilov, R. F. (2004) · Lab on a Chip · doi:10.1039/b403378g · Cited by 571
Generation of Steady Liquid Microthreads and Micron-Sized Monodisperse Sprays in Gas Streams
Gañán-Calvo, A. M. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.285 · Cited by 531
Tan, Y.-C., Fisher, J. S., Lee, A. I., Cristini, V., & Lee, A. P. (2004) · Lab on a Chip · doi:10.1039/b403280m · Cited by 509
Interfacial Tension Driven Monodispersed Droplet Formation from Microfabricated Channel Array
Sugiura, S., Nakajima, M., Iwamoto, S., & Seki, M. (2001) · Langmuir · doi:10.1021/la010342y · Cited by 439
High-Temperature Microfluidic Synthesis of CdSe Nanocrystals in Nanoliter Droplets
Chan, E. M., Alivisatos, A. P., & Mathies, R. A. (2005) · Journal of the American Chemical Society · doi:10.1021/ja051381p · Cited by 376
An Axisymmetric Flow‐Focusing Microfluidic Device
Takeuchi, S., Garstecki, P., Weibel, D. B., & Whitesides, G. M. (2005) · Advanced Materials · doi:10.1002/adma.200401738 · Cited by 370
Droplet breakup mechanisms: Stepwise equilibrium versus transient dispersion
Janssen, J. M. H., & Meijer, H. E. H. (1993) · Journal of Rheology · doi:10.1122/1.550385 · Cited by 190
Zheng, B., Tice, J. D., & Ismagilov, R. F. (2004) · Advanced Materials · doi:10.1002/adma.200400590 · Cited by 163
Nonlinear Dynamics of a Flow-Focusing Bubble Generator: An Inverted Dripping Faucet
Garstecki, P., Fuerstman, M. J., & Whitesides, G. M. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.234502 · Cited by 134
90 Years of Polymer Latexes and Heterophase Polymerization: More vital than ever
Antonietti, M., & Tauer, K. (2003) · Macromolecular Chemistry and Physics · doi:10.1002/macp.200290083 · Cited by 80
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Passive and active droplet generation with microfluidics: a review
Zhu, P., & Wang, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01018k · Cited by 1,238
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Microfluidic methods for generating continuous droplet streams
Christopher, G. F., & Anna, S. L. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/19/r01 · Cited by 860
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
Metadata
- Authors
- Yobas, L., Martens, S., Ong, W.-L., & Ranganathan, N.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 6
- Issue
- 8
- Pages
- 1073
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2062573677
- Cited by
- 293
- References
- 17
- FWCI
- 10.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.