Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 370

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

An Axisymmetric Flow‐Focusing Microfluidic Device

Takeuchi, S., Garstecki, P., Weibel, D. B., Whitesides, G. M.·2005·Advanced Materials

Abstract

An axisymmetric flow-focusing microfluidic device (AFFD) is described. The AFFD (see Figure, top) produces micrometer-sized (50–300 μm) polymer-coated droplets (see Figure, bottom) with narrow size distributions (< 5 %). The axisymmetric geometry confines droplets to the central axis of the channel and prevents them from being sheared or damaged at the channel walls. The device is used to prepare aqueous droplets encapsulated in nylon-6,6 membranes by carrying out interfacial polymerization reactions in situ.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.200401738

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 370

Metadata

Authors
Takeuchi, S., Garstecki, P., Weibel, D. B., & Whitesides, G. M.
Venue
Advanced Materials
Publisher
Wiley
Published
2005-04-07
Volume
17
Issue
8
Pages
1067-1072
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W1966953745
Cited by
370
References
19
FWCI
15.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Axisymmetric Flow‐Focusing Microfluidic Device. https://app.cochat.ai/papers/10.1002/adma.200401738
The paper
Takeuchi, S., Garstecki, P., Weibel, D. B., & Whitesides, G. M. (2005). An Axisymmetric Flow‐Focusing Microfluidic Device. Advanced Materials. https://doi.org/10.1002/adma.200401738

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.