The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
An Axisymmetric Flow‐Focusing Microfluidic Device
Abstract
An axisymmetric flow-focusing microfluidic device (AFFD) is described. The AFFD (see Figure, top) produces micrometer-sized (50–300 μm) polymer-coated droplets (see Figure, bottom) with narrow size distributions (< 5 %). The axisymmetric geometry confines droplets to the central axis of the channel and prevents them from being sheared or damaged at the channel walls. The device is used to prepare aqueous droplets encapsulated in nylon-6,6 membranes by carrying out interfacial polymerization reactions in situ.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Self-citationSolvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Self-citationMicroencapsulated Islets as Bioartificial Endocrine Pancreas
Lim, F., & Sun, A. M. (1980) · Science · doi:10.1126/science.6776628 · Cited by 2,377
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Colloidosomes: Selectively Permeable Capsules Composed of Colloidal Particles
Dinsmore, A. D., Hsu, M. F., Nikolaides, M. G., Marquez, M., Bausch, A. R., & Weitz, D. A. (2002) · Science · doi:10.1126/science.1074868 · Cited by 2,061
Tailor‐Made Polyelectrolyte Microcapsules: From Multilayers to Smart Containers
Peyratout, C. S., & Dähne, L. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200300568 · Cited by 1,031
Micro/Nano encapsulation via electrified coaxial liquid jets
Loscertales, I. G., Barrero, A., Guerrero, I., Cortijo, R., Marquez, M., & Gañán-Calvo, A. M. (2002) · Science · doi:10.1126/science.1067595 · Cited by 1,017
Chang, T. M. S. (1964) · Science · doi:10.1126/science.146.3643.524 · Cited by 1,011
Liquid Morphologies on Structured Surfaces: From Microchannels to Microchips
Gau, H., Herminghaus, S., Lenz, P., & Lipowsky, R. (1999) · Science · doi:10.1126/science.283.5398.46 · Cited by 991
Preparation of microspheres by the solvent evaporation technique
O'Donnell, P. B., & McGinity, J. W. (1997) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(97)00049-5 · Cited by 806
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Self-citationPassive and active droplet generation with microfluidics: a review
Zhu, P., & Wang, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01018k · Cited by 1,238
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Multiphase microfluidics: from flow characteristics to chemical and materials synthesis
Günther, A., & Jensen, K. F. (2006) · Lab Chip · doi:10.1039/b609851g · Cited by 983
Metadata
- Authors
- Takeuchi, S., Garstecki, P., Weibel, D. B., & Whitesides, G. M.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2005-04-07
- Volume
- 17
- Issue
- 8
- Pages
- 1067-1072
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W1966953745
- Cited by
- 370
- References
- 19
- FWCI
- 15.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Axisymmetric Flow‐Focusing Microfluidic Device. https://app.cochat.ai/papers/10.1002/adma.200401738
- The paper
- Takeuchi, S., Garstecki, P., Weibel, D. B., & Whitesides, G. M. (2005). An Axisymmetric Flow‐Focusing Microfluidic Device. Advanced Materials. https://doi.org/10.1002/adma.200401738
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.