The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Continuous sorting of magnetic cells via on-chip free-flow magnetophoresis
Abstract
The ability to separate living cells is an essential aspect of cell research. Magnetic cell separation methods are among some of the most efficient methods for bulk cell separation. With the development of microfluidic platforms within the biotechnology sector, the design of miniaturised magnetic cell sorters is desirable. Here, we report the continuous sorting of cells loaded with magnetic nanoparticles in a microfluidic magnetic separation device. Cells were passed through a microfluidic chamber and were deflected from the direction of flow by means of a magnetic field. Two types of cells were studied, mouse macrophages and human ovarian cancer cells (HeLa cells). The deflection was dependent on the magnetic moment and size of the cells as well as on the applied flow rate. The experimentally observed deflection matched well with calculations. Furthermore, the separation of magnetic and non-magnetic cells was demonstrated using the same microfluidic device.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preparation of aqueous magnetic liquids in alkaline and acidic media
Massart, R. (1981) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1981.1061188 · Cited by 2,817
High gradient magnetic cell separation with MACS
Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990) · Cytometry · doi:10.1002/cyto.990110203 · Cited by 1,681
Medical application of functionalized magnetic nanoparticles
Ito, A., Shinkai, M., Honda, H., & Kobayashi, T. (2005) · Journal of Bioscience and Bioengineering · doi:10.1263/jbb.100.1 · Cited by 1,470
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
Wilhelm, C., Billotey, C., Roger, J., Pons, J. N., Bacri, J.-C., & Gazeau, F. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00440-4 · Cited by 675
Self-citationClC-5 Cl--channel disruption impairs endocytosis in a mouse model for Dent's disease
Piwon, N., Günther, W., Schwake, M., Bösl, M. R., & Jentsch, T. J. (2000) · Nature · doi:10.1038/35042597 · Cited by 551
On-Chip Free-Flow Magnetophoresis: Continuous Flow Separation of Magnetic Particles and Agglomerates
Pamme, N., & Manz, A. (2004) · Analytical Chemistry · doi:10.1021/ac049183o · Cited by 475
Self-citationMarker-specific sorting of rare cells using dielectrophoresis
Hu, X., Bessette, P. H., Qian, J., Meinhart, C. D., Daugherty, P. S., & Soh, H. T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507719102 · Cited by 428
Wilhelm, C., Gazeau, F., Roger, J., Pons, J. N., & Bacri, J.-C. (2002) · Langmuir · doi:10.1021/la0257337 · Cited by 290
Self-citationBillotey, C., Wilhelm, C., Devaud, M., Bacri, J. C., Bittoun, J., & Gazeau, F. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10418 · Cited by 234
Self-citationContinuous cell separation using novel magnetic quadrupole flow sorter
Zborowski, M., Sun, L., Moore, L. R., Stephen Williams, P., & Chalmers, J. J. (1999) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(98)00581-2 · Cited by 209
Magnetophoresis and ferromagnetic resonance of magnetically labeled cells
Wilhelm, F. G. (2002) · European Biophysics Journal · doi:10.1007/s00249-001-0200-4 · Cited by 189
Immunomagnetic T cell capture from blood for PCR analysis using microfluidic systems
Furdui, V. I., & Harrison, D. J. (2004) · Lab on a Chip · doi:10.1039/b409366f · Cited by 152
Yao, B., Luo, G., Feng, X., Wang, W., Chen, L.-X., & Wang, Y. (2004) · Lab on a Chip · doi:10.1039/b408422e · Cited by 139
Self-Sorting of White Blood Cells in a Lattice
Carlson, R. H., Gabel, C. V., Chan, S. S., et al. (1997) · Physical Review Letters · doi:10.1103/physrevlett.79.2149 · Cited by 117
Hansen, S. H., Sandvig, K., & van Deurs, B. (1993) · The Journal of Cell Biology · doi:10.1083/jcb.123.1.89 · Cited by 106
Immunomagnetic cell sorting—pushing the limits
Thiel, A., Scheffold, A., & Radbruch, A. (1998) · Immunotechnology · doi:10.1016/s1380-2933(98)00010-4 · Cited by 94
Rivière, C., Boudghene, F. P., Gazeau, F., et al. (2005) · Radiology · doi:10.1148/radiol.2353032057 · Cited by 91
Sin, A., Murthy, S. K., Revzin, A., Tompkins, R. G., & Toner, M. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20556 · Cited by 85
Harnessing dielectric forces for separations of cells, fine particles and macromolecules
Gonzalez, C. F., & Remcho, V. T. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.03.070 · Cited by 79
Micropillar array chip for integrated white blood cell isolation and PCR
Panaro, N. J., Lou, X. J., Fortina, P. M., et al. (2005) · Biomolecular Engineering · doi:10.1016/j.bioeng.2004.11.001 · Cited by 67
Synnes, M., Prydz, K., Løvdal, T., et al. (1999) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0005-2736(99)00134-0 · Cited by 31
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Biomedical Nanomagnetics: A Spin Through Possibilities in Imaging, Diagnostics, and Therapy
Krishnan, K. M. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2046907 · Cited by 819
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Self-citationMicrofluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Metadata
- Authors
- Pamme, N., & Wilhelm, C.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 6
- Issue
- 8
- Pages
- 974
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1986429246
- Cited by
- 497
- References
- 22
- FWCI
- 13.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.