CoChat

A two-stage cyclone using microcentrifuge tubes for personal bioaerosol sampling.

Lindsley, William G., Schmechel, Detlef, Chen, Bean T. · 2006 · Journal of Environmental Monitoring

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Personal aerosol samplers are widely used to monitor human exposure to airborne materials. For bioaerosols, interest is growing in analyzing samples using molecular and immunological techniques. This paper presents a personal sampler that uses a two-stage cyclone to collect bioaerosols into disposable 1.5 ml Eppendorf-type microcentrifuge tubes. Samples can be processed in the tubes for polymerase chain reaction (PCR) or immunoassays, and the use of multiple stages fractionates aerosol particles by aerodynamic diameter. The sampler was tested using fluorescent microspheres and aerosolized fungal spores. The sampler had first and second stage cut-off diameters of 2.6 microm and 1.6 microm at 2 l min(-1)(geometric standard deviation, GSD = 1.45 and 1.75), and 1.8 microm and 1 microm at 3.5 l min(-1)(GSD = 1.42 and 1.55). The sampler aspiration efficiency was >or=98% at both flow rates for particles with aerodynamic diameters of 3.1 microm or less. For 6.2 microm particles, the aspiration efficiency was 89% at 2 l min(-1) and 96% at 3.5 l min(-1). At 3.5 l min(-1), the sampler collected 92% of aerosolized Aspergillus versicolor and Penicillium chrysogenum spores inside the two microcentrifuge tubes, with less than 0.4% of the spores collecting on the back-up filter. The design and techniques given here are suitable for personal bioaerosol sampling, and could also be adapted to design larger aerosol samplers for longer-term atmospheric and indoor air quality sampling.

Overview

Integrity signals

Registry

Crossref · 10.1039/b609083d

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Research works printed but not linked: 1

  1. Gorny, 1999, Ann. Agric. Environ. Med., 6, 105

Cited by

See all 121

Metadata

Authors
Lindsley, W. G., Schmechel, D., & Chen, B. T.
Affiliations
Centers for Disease Control and Prevention (US)
Corresponding author
Lindsley, William G.
Venue
Journal of Environmental Monitoring
Published
2006
Volume
8
Issue
11
Pages
1136
ISSN
  • 1464-0325 (ISSN-L)
  • 1464-0333
OpenAlex
W1977029565
Cited by
117
References
23
Citations by year
2026: 3 · 2025: 5 · 2024: 3 · 2023: 10 · 2022: 4 · 2021: 12 · 2020: 4 · 2019: 7 · 2018: 10 · 2017: 8 · 2016: 7 · 2015: 5 · 2014: 8 · 2013: 7 · 2012: 7
FWCI
1.52
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Environmental Monitoring (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Physical Sciences › Engineering › Computational Mechanics › Cyclone Separators and Fluid Dynamics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
Keywords
microcentrifuge tubes, aerodynamic diameter, aspiration efficiency, fungal spores, Aspergillus versicolor, Penicillium chrysogenum, indoor air quality
MeSH terms
Aerosols, Bacteria, Centrifugation, Environmental Monitoring, Enzyme-Linked Immunosorbent Assay, Fungi, Humans, Particle Size, Spores, Fungal, Polymerase Chain Reaction, Occupational Exposure, Air Pollution, Indoor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.