A two-stage cyclone using microcentrifuge tubes for personal bioaerosol sampling.
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Personal aerosol samplers are widely used to monitor human exposure to airborne materials. For bioaerosols, interest is growing in analyzing samples using molecular and immunological techniques. This paper presents a personal sampler that uses a two-stage cyclone to collect bioaerosols into disposable 1.5 ml Eppendorf-type microcentrifuge tubes. Samples can be processed in the tubes for polymerase chain reaction (PCR) or immunoassays, and the use of multiple stages fractionates aerosol particles by aerodynamic diameter. The sampler was tested using fluorescent microspheres and aerosolized fungal spores. The sampler had first and second stage cut-off diameters of 2.6 microm and 1.6 microm at 2 l min(-1)(geometric standard deviation, GSD = 1.45 and 1.75), and 1.8 microm and 1 microm at 3.5 l min(-1)(GSD = 1.42 and 1.55). The sampler aspiration efficiency was >or=98% at both flow rates for particles with aerodynamic diameters of 3.1 microm or less. For 6.2 microm particles, the aspiration efficiency was 89% at 2 l min(-1) and 96% at 3.5 l min(-1). At 3.5 l min(-1), the sampler collected 92% of aerosolized Aspergillus versicolor and Penicillium chrysogenum spores inside the two microcentrifuge tubes, with less than 0.4% of the spores collecting on the back-up filter. The design and techniques given here are suitable for personal bioaerosol sampling, and could also be adapted to design larger aerosol samplers for longer-term atmospheric and indoor air quality sampling.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Fungal Fragments as Indoor Air Biocontaminants
Górny, R. L., Reponen, T., Willeke, K., Schmechel, D., Robine, E., Boissier, M., & Grinshpun, S. A. (2002) · Applied and Environmental Microbiology · doi:10.1128/aem.68.7.3522-3531.2002 · Cited by 402
Self-citationHealth Risk Assessment of Fungi in Home Environments
Verhoeff, A. P., & Burge, H. A. (1997) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)63214-0 · Cited by 254
Airborne fungal fragments and allergenicity
Green, B. J., Tovey, E. R., Sercombe, J. K., Blachere, F. M., Beezhold, D. H., & Schmechel, D. (2006) · Medical Mycology · doi:10.1080/13693780600776308 · Cited by 214
Self-citationEffect of relative humidity on the aerodynamic diameter and respiratory deposition of fungal spores
Reponen, T., Willeke, K., Ulevicius, V., Reponen, A., & Grinshpun, S. A. (1996) · Atmospheric Environment · doi:10.1016/1352-2310(96)00128-8 · Cited by 170
Fungal fragments and undocumented conidia function as new aeroallergen sources
Green, B. J., Sercombe, J. K., & Tovey, E. R. (2005) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2005.02.009 · Cited by 148
Brasel, T. L., Douglas, D. R., Wilson, S. C., & Straus, D. C. (2005) · Applied and Environmental Microbiology · doi:10.1128/aem.71.1.114-122.2005 · Cited by 136
Size distribution of bacterial and fungal bioaerosols in indoor air.
Górny, R. L., Dutkiewicz, J. K., & Krysińska‐Traczyk, E. (1999) · PubMed · Cited by 131
Aerodynamic characteristics and respiratory deposition of fungal fragments
Cho, S., Seo, S., Schmechel, D., Grinshpun, S. A., & Reponen, T. A. (2005) · Atmospheric Environment · doi:10.1016/j.atmosenv.2005.05.042 · Cited by 125
Self-citationEffect of Sampling Time on the Collection Efficiency of All-Glass Impingers
Lin, X., Willeke, K., Ulevicius, V., & Grinshpun, S. A. (1997) · American Industrial Hygiene Association Journal · doi:10.1080/15428119791012577 · Cited by 124
Characteristics of Airborne Actinomycete Spores
Reponen, T. A., Gazenko, S. V., Grinshpun, S. A., Willeke, K., & Cole, E. C. (1998) · Applied and Environmental Microbiology · doi:10.1128/aem.64.10.3807-3812.1998 · Cited by 86
Research works printed but not linked: 1
- Gorny, 1999, Ann. Agric. Environ. Med., 6, 105
Cited by
Measurement of Airborne Influenza Virus in a Hospital Emergency Department
Blachere, F. M., Lindsley, W. G., Pearce, T. A., Anderson, S. E., Fisher, M., Khakoo, R., Meade, B. J., Lander, O., Davis, S., Thewlis, R. E., et al. (2009) · Clinical Infectious Diseases · doi:10.1086/596478 · Cited by 342
“conjunction with a novel cyclone aerosol sampler [11].”
BackgroundMethodSelf-citationCollection, particle sizing and detection of airborne viruses
Pan, M., Lednicky, J. A., & Wu, C. ‐. (2019) · Journal of Applied Microbiology · doi:10.1111/jam.14278 · Cited by 261
“One sampler developed by the National Institute for Occupational Safety and Health (NIOSH) (Lindsley et al. 2006) is a multistage cyclone operating at a flowrate of 3 5 l min 1: the first stage is a 15-ml tube that collects aerosol particles >4 lm, the second is a 1 5 ml tube that collects particles between 1 and 4 lm…”
BackgroundInfluentialChamber Bioaerosol Study: Outdoor Air and Human Occupants as Sources of Indoor Airborne Microbes
Adams, R. I., Bhangar, S., Pasut, W., Arens, E. A., Taylor, J. W., Lindow, S. E., Nazaroff, W. W., & Bruns, T. D. (2015) · PLOS ONE · doi:10.1371/journal.pone.0128022 · Cited by 246
“The NIOSH cyclone sampler requires a lower flow rate vacuum pump, and successful use of this sampler in environmental settings has been based on longer sampling times [53] than we used here.”
MethodBioaerosol sampling: Classical approaches, advances, and perspectives
Mainelis, G. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1671950 · Cited by 229
“Researchers from the National Institute for Occupational Safety and Health (NIOSH) recently developed and successfully used in the field a microcentrifuge-tube cyclone (Lindsley, Schmechel, and Chen 2006; Macher, Chen, and Rao 2008; Su et al. 2012b).”
MethodComparison of Five Bacteriophages as Models for Viral Aerosol Studies
Turgeon, N., Toulouse, M.-J., Martel, B., Moineau, S., & Duchaine, C. (2014) · Applied and Environmental Microbiology · doi:10.1128/aem.00767-14 · Cited by 209
“The NIOSH two-stage bioaerosol sampler (29) has been previously shown to efficiently 383 sample phages (4-6, 30, 52) and influenza viruses (7).”
MethodHigh Humidity Leads to Loss of Infectious Influenza Virus from Simulated Coughs
Noti, J. D., Blachere, F. M., McMillen, C. M., Lindsley, W. G., Kashon, M. L., Slaughter, D. R., & Beezhold, D. H. (2013) · PLoS ONE · doi:10.1371/journal.pone.0057485 · Cited by 200
“4 mm, 1–4 mm, and ,1 mm aerodynamic diameters), were used to collect influenza-containing aerosols [12,22].”
MethodSelf-citationThe size and culturability of patient-generated SARS-CoV-2 aerosol
Santarpia, J. L., Herrera, V. L., Rivera, D. N., Ratnesar-Shumate, S., Reid, S. P., Ackerman, D. N., Denton, P. W., Martens, J. W. S., Fang, Y., Conoan, N., et al. (2022) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-021-00376-8 · Cited by 196
Pestka, J. J., Yike, I., Dearborn, D. G., Ward, M. D. W., & Harkema, J. R. (2008) · Toxicological Sciences · doi:10.1093/toxsci/kfm284 · Cited by 178
“One notable recent advance in this area is the development of a personal sampler that uses a twostage cyclone to collect bioaerosols into disposable microcentrifuge tubes (Lindsley et al., 2006).”
BackgroundInnovations in air sampling to detect plant pathogens
West, J. S., & Kimber, R. B. E. (2015) · Annals of Applied Biology · doi:10.1111/aab.12191 · Cited by 162
Noti, J. D., Lindsley, W. G., Blachere, F. M., Cao, G., Kashon, M. L., Thewlis, R. E., McMillen, C. M., King, W. P., Szalajda, J. V., & Beezhold, D. H. (2012) · Clinical Infectious Diseases · doi:10.1093/cid/cis237 · Cited by 170
“4-, 1–4-, and,1-lm aerodynamic diameters), were used to collect influenza-containing aerosols [24, 27].”
Self-citationRecent advancements in the measurement of pathogenic airborne viruses
Bhardwaj, J., Hong, S., Jang, J., Han, C.-H., Lee, J., & Jang, J. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.126574 · Cited by 107
“The NIOSH developed a portable two-stage dry cyclone sampler with an embedded filter (Lindsley et al., 2006).”
MethodCao, G., Noti, J. D., Blachère, F. M., Lindsley, W. G., & Beezhold, D. H. (2011) · Journal of Environmental Monitoring · doi:10.1039/c1em10607d · Cited by 90
Self-citationMorris, A. C., Sharrocks, K., Bousfield, R., Kermack, L. M., Maes, M., Higginson, E. E., Forrest, S., Pereira-Dias, J., Cormie, C., Old, T., et al. (2021) · Clinical Infectious Diseases · doi:10.1093/cid/ciab933 · Cited by 95
Zhou, J., Wu, J., Zeng, X., Huang, G., Zou, L., Song, Y., Gopinath, D., Zhang, X., Kang, M., Lin, J., et al. (2016) · Eurosurveillance · doi:10.2807/1560-7917.es.2016.21.35.30331 · Cited by 83
Self-citationLecours, P. B., Veillette, M., Marsolais, D., & Duchaine, C. (2012) · Applied and Environmental Microbiology · doi:10.1128/aem.07661-11 · Cited by 76
“9% saline solution; and the NIOSH two-stage bioaerosol cyclone (BC 251) sampler (31, 42), plugged into an AirCon-2 pump (Gilian) and sampling at 10 liters/min for particulate size separation.”
BackgroundMethodBrincat, J., Sardella, D., Muscat, A., Decelis, S., Grima, J. N., Valdramidis, V., & Gatt, R. (2016) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2016.01.015 · Cited by 75
Airborne Fungal Spore Review, New Advances and Automatisation
Martínez‐Bracero, M., Markey, E., Clancy, J. H., McGillicuddy, E. J., Sewell, G., & O’Connor, D. J. (2022) · Atmosphere · doi:10.3390/atmos13020308 · Cited by 76
“Cyclone samplers have also been designed to be small enough to be used as personal samplers [94].”
BackgroundAdhikari, A., Jung, J. H., Reponen, T. A., Lewis, J. S., DeGrasse, E. C., Grimsley, L. F., Chew, G. L., & Grinshpun, S. A. (2009) · Environmental Research · doi:10.1016/j.envres.2008.12.010 · Cited by 66
Quantification of Influenza Virus RNA in Aerosols in Patient Rooms
Leung, N. H. L., Zhou, J., Chu, D. K. W., Yu, H., Lindsley, W. G., Beezhold, D. H., Yen, H.-L., Li, Y., Seto, W.-H., Peiris, J. S. M., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0148669 · Cited by 63
“The tripod, air tubing, sound-proof box and the meter were disinfected with Med-Clean (M&W International Ltd., Hong Kong), the NIOSH air samplers with 2% Citranox (Alconox Inc, NY, USA), and the filter cassettes were autoclaved.”
MethodInfluentialSelf-citationAirborne Transmission of Highly Pathogenic Influenza Virus during Processing of Infected Poultry
Bertran, K., Balzli, C. L., Kwon, Y., Tumpey, T. M., Clark, A., & Swayne, D. E. (2017) · Emerging infectious diseases · doi:10.3201/eid2311.170672 · Cited by 66
Assays and enumeration of bioaerosols-traditional approaches to modern practices
King, M. D., Lacey, R. E., Pak, H., Fearing, A., Ramos, G. E., Baig, T. A., Smith, B. L., & Koustova, A. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2020.1723789 · Cited by 63
“…viability, cyclonebased bioaerosol samplers including the BioSamplerVR , NIOSH two-stage cyclone, CoriolisVR and the wetted wall cyclone (WWC) were developed (Willeke, Lin, and Grinshpun 1998; Chen et al. 2004; Lindsley, Schmechel, and Chen 2006; Carvalho et al. 2008; McFarland et al. 2010).”
MethodRittenour, W. R., Ciaccio, C. E., Barnes, C. S., Kashon, M. L., Lemons, A. R., Beezhold, D. H., & Green, B. J. (2013) · Environmental Science Processes & Impacts · doi:10.1039/c3em00441d · Cited by 54
SARS-CoV-2 in residential rooms of two self-isolating persons with COVID-19
Shankar, S. N., Witanachchi, C. T., Morea, A. F., Lednicky, J. A., Loeb, J. C., Alam, M. M., Fan, Z. H., Eiguren-Fernandez, A., & Wu, C. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105870 · Cited by 54
“The 2-stage cyclone aerosol sampler (NIOSH bioaerosol sampler, BC-251) developed by Lindsley et al. (2006) was run at 3 LPM with Airchek PCXR4 pump.”
Linking the conventional and emerging detection techniques for ambient bioaerosols: a review
Ghimire, P. S., Tripathee, L., Chen, P., & Kang, S. (2019) · Reviews in Environmental Science and Bio/Technology · doi:10.1007/s11157-019-09506-z · Cited by 56
“…collection Ease of sterilization process Chances of drying of liquid medium due to evaporation is maximum Griffiths and Boysan (1996 and Lindsley et al. 2006) NIOSH Bio sampler 4.0 L/min Large volume aerosol samplers Based on principle of rotary arm impactor Bio capture BT 550 150L/min…”
MethodInfluentialBioaerosol sampling for the detection of aerosolized influenza virus
Blachère, F. M., Lindsley, W. G., Slaven, J. E., Green, B. J., Anderson, S. E., Chen, B. T., & Beezhold, D. H. (2007) · Influenza and Other Respiratory Viruses · doi:10.1111/j.1750-2659.2007.00020.x · Cited by 57
Self-citationComparison of quantitative airborne fungi measurements by active and passive sampling methods
Yamamoto, N., Schmechel, D., Chen, B. T., Lindsley, W. G., & Peccia, J. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2011.05.004 · Cited by 50
Self-citationDetection ofParacoccidioidesspp. in environmental aerosol samples
Arantes, T. D., Theodoro, R. C., Macoris, S. A. D. G., & Bagagli, E. (2012) · Medical Mycology · doi:10.3109/13693786.2012.698444 · Cited by 49
Lee, S.-A., & Liao, C.-H. (2014) · Science of The Total Environment · doi:10.1016/j.scitotenv.2013.07.104 · Cited by 48
Sampling for Airborne Microorganisms
Grinshpun, S. A., Buttner, M. P., Mainelis, G., & Willeke, K. (2015) · ASM Press eBooks · doi:10.1128/9781555818821.ch3.2.2 · Cited by 56
Comparison of samplers collecting airborne influenza viruses: 1. Primarily impingers and cyclones
Raynor, P. C., Adesina, A., Aboubakr, H. A., Yang, M., Torremorell, M., & Goyal, S. M. (2021) · PLoS ONE · doi:10.1371/journal.pone.0244977 · Cited by 48
“The National Institute for Occupational Safety and Health (NIOSH) Cyclone Bioaerosol Sampler, a sampler worn by an individual, utilizes a pair of cyclones in series to collect biological aerosols into microcentrifuge tubes, followed by a backup filter [41].”
BackgroundMethodDetection and analysis of airborne particles of biological origin: present and future
Caruana, D. J. (2011) · The Analyst · doi:10.1039/c1an15506g · Cited by 43
Dustborne and airborne Gram-positive and Gram-negative bacteria in high versus low ERMI homes
Adhikari, A., Kettleson, E. M., Vesper, S. J., Kumar, S., Popham, D. L., Schaffer, C., Indugula, R., Chatterjee, K., Allam, K. K., Grinshpun, S. A., et al. (2014) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2014.02.110 · Cited by 40
“Air samples (5.47 ± 0.54 m3 air) were collected at 3.5 l/min over a 24-h period using a NIOSH-developed 2-stage cyclone sampler, which separates airborne particles into three size fractions: < 1.0 μm, 1.0–1.8 μm, and >1.8 μm (Lindsley et al., 2006).”
MethodInfluentialVass, W. B., Lednicky, J. A., Shankar, S. N., Fan, Z. H., Eiguren-Fernandez, A., & Wu, C. (2022) · SSRN Electronic Journal · doi:10.2139/ssrn.4100428 · Cited by 43
Humidity as a non-pharmaceutical intervention for influenza A
Reiman, J. M., Das, B. B., Sindberg, G. M., Urban, M. D., Hammerlund, M. E. M., Lee, H. B., Spring, K. M., Gingerich, J. L., Generous, A. R., Koep, T. H., et al. (2018) · PLoS ONE · doi:10.1371/journal.pone.0204337 · Cited by 39
“NIOSH two-stage bioaerosol cyclone samplers[31, 32] collected air samples and separated them into three size fractions (>4 μm, 1–4 μm, and<1 μm) at a flow rate of 3.”
Fisher, E. M., Noti, J. D., Lindsley, W. G., Blachère, F. M., & Shaffer, R. E. (2014) · Risk Analysis · doi:10.1111/risa.12185 · Cited by 44
Self-citationEnhanced detection of infectious airborne influenza virus
Blachère, F. M., Cao, G., Lindsley, W. G., Noti, J. D., & Beezhold, D. H. (2011) · Journal of Virological Methods · doi:10.1016/j.jviromet.2011.05.030 · Cited by 36
Self-citationAfanou, A. K., Straumfors, A., Skogstad, A., Skaar, I., Hjeljord, L. G., Skare, Ø., Green, B. J., Tronsmo, A., & Eduard, W. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1040486 · Cited by 40
“However, the problem of spore bounce associated with impactor and cyclone sampling (Lindsley et al. 2006; Madsen et al. 2009) as well as the cut-off characteristics of impactors and cyclones suggest possible contamination of the submicronic fragment fraction by larger particles.”
Kettleson, E. M., Kumar, S., Reponen, T., Vesper, S. J., Méheust, D., Grinshpun, S. A., & Adhikari, A. (2013) · Indoor Air · doi:10.1111/ina.12035 · Cited by 38
“Air samples were collected from 38 of the 42 homes at 3.5 l/min over a 24-h period using a NIOSH-developed 2-stage cyclone sampler, which classifies airborne particles in three size fractions: < 1.0 lm, 1.0-1.8 lm, and >1.8 lm (Lindsley et al., 2006) .”
InfluentialAirborne fungal cell fragments in homes in relation to total fungal biomass
Adhikari, A., Reponen, T., & Rylander, R. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00799.x · Cited by 34
“The design and performance characteristics of the NIOSH two-stage cyclone sampler have been described previously (Lindsley et al., 2006).”
MethodWei, J., Zhou, J., Cheng, K. L., Wu, J., Zhong, Z., Song, Y., Ke, C., Yen, H., & Li, Y. (2017) · Building and Environment · doi:10.1016/j.buildenv.2017.10.037 · Cited by 32
Green, B. J., Schmechel, D., & Summerbell, R. C. (2011) · Wageningen Academic Publishers eBooks · doi:10.3920/978-90-8686-722-6_8 · Cited by 34
Self-citationBlachère, F. M., Lindsley, W. G., McMillen, C. M., Beezhold, D. H., Fisher, E. M., Shaffer, R. E., & Noti, J. D. (2018) · Journal of Virological Methods · doi:10.1016/j.jviromet.2018.05.009 · Cited by 34
“, 2012) The room included a HEPA filtration system to remove airborne particles before/after testing, an ultraviolet germicidal irradiation system to disinfect the room between experiments, NIOSH BC 251 two-stage cyclone samplers (Lindsley et al., 2006), and coughing and breathing simulators to mimic a coughing patien…”
MethodSelf-citationA microfluidics-based on-chip impinger for airborne particle collection
Mirzaee, I., Song, M., Charmchi, M., & Sun, H. (2016) · Lab on a Chip · doi:10.1039/c6lc00040a · Cited by 29
A Robot Assisted High-flow Portable Cyclone Sampler for Bacterial and SARS-CoV-2 Aerosols
Li, X., Chen, H., Qi, X., Peng, Y., Zhou, L., Ma, J., & Yao, M. (2021) · Aerosol and Air Quality Research · doi:10.4209/aaqr.210130 · Cited by 28
“For example, various samplers such as SASS 2300 (Ma et al. , 2020), Coriolis µ (Rufino de Sousa et al. , 2020) and NIOSH sampler (Chen et al. , 2004; Lindsley et al. , 2006) were developed.”
Airborne Endotoxin and ß-D-glucan in PM1 in Agricultural and Home Environments
Singh, U. P., Reponen, T. A., Cho, K. J., Grinshpun, S. A., Adhikari, A., Levin, L. S., Indugula, R., & Green, B. J. (2011) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2011.03.0019 · Cited by 33
“The NIOSH two-stage air sampler [BC212, described by Lindsley et al. (2006)] was used in this study for collecting airborne particles from the farm and home environments.”
MethodInfluence of home characteristics on airborne and dustborne endotoxin and β-d-glucan
Singh, U. P., Levin, L. S., Grinshpun, S. A., Schaffer, C., Adhikari, A., & Reponen, T. A. (2011) · Journal of Environmental Monitoring · doi:10.1039/c1em10446b · Cited by 27
The level of submicron fungal fragments in homes with asthmatic children
Seo, S., Choung, J. T., Chen, B. T., Lindsley, W. G., & Kim, K. Y. (2014) · Environmental Research · doi:10.1016/j.envres.2014.02.015 · Cited by 27
“two-stage sampler (Lindsley et al., 2006) as described in detail elsewhere (Seo”
Self-citationHan, T., Thomas, N. M., & Mainelis, G. (2017) · Aerosol Science and Technology · doi:10.1080/02786826.2017.1329516 · Cited by 27
“Several new personal bioaerosol sampler concepts, such as rotating cup (Gorner et al. 2006) and microcentrifuge tube (Lindsley et al. 2006; Macher et al. 2008; Su et al. 2012) have been proposed.”
BackgroundA novel system for the comprehensive collection of nonvolatile molecules from human exhaled breath
Chen, D., Bryden, W. A., & McLoughlin, M. J. (2020) · Journal of Breath Research · doi:10.1088/1752-7163/abba87 · Cited by 24
Rule, A. M., Geyh, A. S., Ramos-Bonilla, J. P., Mihalic, J. N., Margulies, J. D., Polyak, L. M., Kesavan, J. S., & Breysse, P. N. (2010) · Journal of Environmental Monitoring · doi:10.1039/c0em00034e · Cited by 24
Analysis of Airborne Biomarkers for Point-of-Care Diagnostics
Fung, A. O., & Mykhaylova, N. (2014) · SLAS TECHNOLOGY · doi:10.1177/2211068213517119 · Cited by 22
Design and Performance of a Low-Cost Micro-Channel Aerosol Collector
Novosselov, I. V., Gorder, R. A., Amberg, J. A. V., & Ariessohn, P. C. (2014) · Aerosol Science and Technology · doi:10.1080/02786826.2014.932895 · Cited by 21
“, SASS 2300, SKC biosampler, or the micro-centrifuge personal bioaerosol sampler (Lindsey et al. 2006) the mCC is principally different as it collects the sample onto a solid substrate allowing the sample to be eluted later into a small liquid volume (less than 100 mL) compatible with microfluidic devices and standard…”
MethodSu, W., Tolchinsky, A. D., Chen, B. T., Иванович, С. В., & Cheng, Y. S. (2012) · Journal of Environmental Monitoring · doi:10.1039/c2em30299c · Cited by 21
Self-citationBiomonitoring the indoor environment of agricultural buildings
Švajlenka, J., Kozlovská, M., & Pošiváková, T. (2018) · Annals of Agricultural and Environmental Medicine · doi:10.26444/aaem/81314 · Cited by 21
Indirect Immunodetection of Fungal Fragments by Field Emission Scanning Electron Microscopy
Afanou, A. K., Straumfors, A., Skogstad, A., Nayak, A. P., Skaar, I., Hjeljord, L. G., Tronsmo, A., Eduard, W., & Green, B. J. (2015) · Applied and Environmental Microbiology · doi:10.1128/aem.00929-15 · Cited by 19
“However, these studies were limited by the imprecise fractionation of particles due to confounding variables such as spore bounce (18, 47, 48).”
BackgroundSantarpia, J. L., Klug, E., Ravnholdt, A. R., & Kinahan, S. (2023) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2023.2197825 · Cited by 21
Vass, W. B., Shankar, S. N., Lednicky, J. A., Yang, Y., Manzanas, C., Zhang, Y., Boyette, J. A., Chen, J., Chen, Y., Shirkhani, A., et al. (2023) · Aerosol Science and Technology · doi:10.1080/02786826.2023.2251537 · Cited by 18
Shiu, E. Y. C., Huang, W., Ye, D., Xie, Y., Mo, J., Li, Y., Cowling, B. J., Yang, Z., & Leung, N. (2020) · Indoor Air · doi:10.1111/ina.12669 · Cited by 18
Assessment and biomonitoring indoor environment of buildings
Švajlenka, J., Kozlovská, M., & Pošiváková, T. (2017) · International Journal of Environmental Health Research · doi:10.1080/09603123.2017.1373276 · Cited by 21
“They are also used cyclone personal samplers enabling particle size fractioning which collect bioaerosols into microcentrifuge tubes (Lindsley et al. 2006).”
MethodFungal Fragments and Fungal Aerosol Composition in Sawmills
Afanou, A. K., Eduard, W., Johnsen, H. L., & Straumfors, A. (2018) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxy022 · Cited by 19
“However, as opposed to the present study, these detection approaches could not confidently confirm the fungal origin of the measured biomarkers because of the imperfect fractionation of SF from spores (Lindsley et al., 2006) and the fact that beta-glucans or NAHA can originate from plants and insects.”
ResultChamber Evaluation of a Personal, Bioaerosol Cyclone Sampler
Macher, J. M., Chen, B. T., & Rao, C. Y. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802380351 · Cited by 18
“A two-stage version of the cyclone also has been characterized for collection of PSL particles and fungal spores.(12) The current evaluation of the personal cyclone consisted of tests in a sealed glove box for two types of laboratory-generated spores at varying concentrations and for sampling times ranging from 0.”
Self-citationBertran, K., Clark, A., & Swayne, D. E. (2018) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2018.05.013 · Cited by 21
Characterization of Microorganisms in Indoor Environments
Lignell, U. (2008) · STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) · Cited by 19
Droplet digital PCR application for the detection of SARS-CoV-2 in air sample
Rashid, S. A., Nazakat, R., Robat, R. M., Ismail, R., Suppiah, J., Rajendran, K., Masalamany, A. S. S. R. L., Hendri, N. A. M., Mohamad, N., Hasni, N. A. K., et al. (2023) · Frontiers in Public Health · doi:10.3389/fpubh.2023.1208348 · Cited by 17
Han, T., Thomas, N. M., & Mainelis, G. (2018) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2018.07.004 · Cited by 16
Indoor air sampling for detection of viral nucleic acids
Justen, L. J., Grimm, S. L., Esvelt, K. M., & Bradshaw, W. J. (2025) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2025.106549 · Cited by 19
Ahrenholz, S. H., Brueck, S., Rule, A. M., Noti, J. D., Noorbakhsh, B., Blachère, F. M., de Perio, M. A., Lindsley, W. G., Shaffer, R. E., & Fisher, E. M. (2018) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1486509 · Cited by 14
Self-citationKuo, F.-Y., Lin, Y.-C., Ke, L.-Y., Tsai, C., & Yao, D. (2018) · Micromachines · doi:10.3390/mi9080398 · Cited by 13
“Lindsley and coworkers were the first to use a microcentrifuge tube as a replaceable cyclone separator for bi aero ol s mpling [14].”
MethodNeuraminidase Activity as a Potential Enzymatic Marker for Rapid Detection of Airborne Viruses
Turgeon, N., McNicoll, F., Toulouse, M.-J., Liav, A., Barbeau, J., Ho, J., Grund, C., & Duchaine, C. (2010) · Aerosol Science and Technology · doi:10.1080/02786826.2010.530624 · Cited by 13
“Recently, the National Institute for Occupational Safety and Health (NIOSH) developed a 2-stage cyclone simpler (Lindsley et al. 2006).”
BackgroundInfluentialSimon, X., Bau, S., Boivin, A., Duquenne, P., Witschger, O., & Görner, P. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1166173 · Cited by 13
“, 2004) and of the first tube of the 2 L/min two-stage cyclone (Lindsley et al., 2006), developed by the National Institute for Occupational Safety and Health (NIOSH).”
BackgroundStelzer‐Braid, S., Liu, N., Doumit, M., D'Cunha, R., Belessis, Y., Jaffé, A., & Rawlinson, W. D. (2017) · Journal of Medical Virology · doi:10.1002/jmv.24794 · Cited by 13
“Air samples from the CF outpatient clinic and operating theatre (OT) were collected using Institute of Occupational Medicine (IOM) (Edinburgh, Scotland) samplers and 2-stage cyclone air samplers (2CAS).(13) IOM samplers were worn on a backpack by the physician performing the bronchoscopy, or by the CF clinic's physiot…”
MethodFungal aerosol composition in moldy basements
Afanou, A. K., Straumfors, A., & Eduard, W. (2019) · Indoor Air · doi:10.1111/ina.12567 · Cited by 14
High-volume sampler for size-selective sampling of bioaerosols including viruses
Lim, J.-H., Nam, S. H., Kim, J.-W., Kim, N. H., Park, G.-S., Maeng, J.-S., & Yook, S. (2021) · Atmospheric Environment · doi:10.1016/j.atmosenv.2021.118720 · Cited by 13
Amato, P., Brisebois, E., Draghi, M., Duchaine, C., Fröhlich‐Nowoisky, J., Huffman, J. A., Mainelis, G., Robine, E., & Thibaudon, M. (2017) · Wiley eBooks · doi:10.1002/9781119132318.ch1b · Cited by 13
Assessment of indoor bioaerosols using a lab-made virtual impactor
Nasrabadi, A. M., Park, J. W., Kim, H. S., Han, J. S., Hyun, J., Yong, D., & Hwang, J. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1246707 · Cited by 12
“(2014), using the NIOSH two-stage sampler (Lindsley et al. 2006), have reported that submicron-sized fungal fragments are significantly higher in the homes of asthmatic children than those in non-asthmatic children.”
MethodDesign of micro interconnected fluidized bed for oxygen carrier evaluation
Shen, T., Zhu, X., Yan, J., & Shen, L. (2019) · International journal of greenhouse gas control · doi:10.1016/j.ijggc.2019.102806 · Cited by 11
Occupational exposure monitoring of airborne respiratory viruses in outpatient medical clinics
Vass, W. B., Shirkhani, A., Washeem, M., Shankar, S. N., Zhang, Y., Moquin, T. L., Messcher, R. L., Jansen, M. D., Clugston, J. R., Walser, M. P., et al. (2024) · Aerosol Science and Technology · doi:10.1080/02786826.2024.2403580 · Cited by 11
“The second sampler type was the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Sampler (Model BC-251), which likewise has been described previously (Cao et al. 2011; Lindsley, Schmechel, and Chen 2006).”
Performance evaluation of two personal bioaerosol samplers
Tolchinsky, A. D., Иванович, С. В., Varfolomeev, A. N., Успенская, С. Н., Cheng, Y. S., & Su, W. (2011) · Journal of Environmental Science and Health Part A · doi:10.1080/10934529.2011.623957 · Cited by 10
Evaluation of a novel personal nanoparticle sampler
Zhou, Y., Irshad, H., Tsai, C., Hung, S.-M., & Cheng, Y. (2013) · Environmental Science Processes & Impacts · doi:10.1039/c3em00497j · Cited by 9
The Optimization of Methods for the Collection of Aerosolized Murine Norovirus
Boles, C., Brown, G., Park, J. H., & Nonnenmann, M. W. (2020) · Food and Environmental Virology · doi:10.1007/s12560-020-09430-4 · Cited by 8
Muthalagu, A., Niculita‐Hirzel, H., Shen, Y., Merizak, M., Pikridas, M., Qureshi, A., Wargocki, P. L., Bekö, G., Williams, J., Täubel, M., et al. (2023) · Building and Environment · doi:10.1016/j.buildenv.2023.110458 · Cited by 8
Wei, J., Zhou, J., Liu, Y., Wu, J., Jin, T., Li, Y., & Yen, H. (2019) · PLoS ONE · doi:10.1371/journal.pone.0216478 · Cited by 8
Martín, E., Dziurowitz, N., Jäckel, U., & Schäfer, J. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2014.946514 · Cited by 8
“Based on this single-stage personal sampler, Lindsley et al.(20) developed a two-stage version which allows size-fractionated particle collection according to their aerodynamic diameter for potential differentiation of microbial species.”
BackgroundMethodInfluentialWang, Y., Wei, J., Gao, C. X., Jin, T., & Liu, L. (2023) · Building Simulation · doi:10.1007/s12273-022-0982-0 · Cited by 7
“Due to the inertial impaction and gravitational deposition losses of larger droplets, efficient sampling of droplets larger than 10 μm is rather difficult for existing respiratory droplets samplers such as G-II developed by the Harvard University (McDevitt et al 2013) and the three-stage cyclone-based bioaerosol sampl…”
MethodInfluentialHu, Y., Peng, S., Su, B., Wang, T., Lin, J., Sun, W. D., Hu, X., Zhang, G., Wang, X., Peng, P., et al. (2024) · Fundamental Research · doi:10.1016/j.fmre.2023.12.017 · Cited by 9
“A portable two-stage cyclone developed by the National Institute for Occupational Safety and Health (NIOSH) consists of two 1.5 mL centrifuge tubes, enabling low flow operation [57] .”
MethodInfluentialGregorio, P., Mariani, A. W., Brito, J. M. L. T., Santos, B. J. M., & Pêgo‐Fernandes, P. M. (2021) · Journal of Occupational and Environmental Medicine · doi:10.1097/jom.0000000000002284 · Cited by 8
Stein, S. J., Ravnholdt, A. R., Herrera, V. L., Rivera, D. N., Williams, P. T., & Santarpia, J. L. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20020976 · Cited by 7
Hwang, S. H., Park, D. U., & Yoon, C. S. (2017) · Human and Ecological Risk Assessment An International Journal · doi:10.1080/10807039.2017.1321955 · Cited by 6
“3)-b-D-glucan levels, a newly developed two-stage bioaerosol cyclone 221 sampler was used for an average of 6 h (Lindsley et al. 2006).”
MethodAdvancements in Airborne Viral Nucleic Acid Detection with Wearable Devices
Godin, R., Hejazi, S., & Reuel, N. F. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202300061 · Cited by 5
Development of Three-Stage Bioaerosol Sampler for Size-Selective Sampling
Lim, J.-H., Nam, S. H., Kim, J., Kim, N. H., Park, G.-S., Maeng, J.-S., & Yook, S.-J. (2022) · Journal of Biomechanical Engineering · doi:10.1115/1.4053504 · Cited by 6
Alfaro-Perez, C., Barberá-Riera, M., de Llanos, R., & Delgado-Saborit, J. M. (2025) · npj Climate and Atmospheric Science · doi:10.1038/s41612-025-01180-z · Cited by 5
Chen, Y., Chen, J., Shankar, S. N., Amanatidis, S., Eiguren-Fernandez, A., Kreisberg, N. M., Spielman, S., Lednicky, J. A., & Wu, C. (2024) · Aerosol Science and Technology · doi:10.1080/02786826.2024.2301941 · Cited by 5
“Lindsley, Schmechel, and Chen (2006) reported that a prototype 2-stage cyclone sampler collected over 75% of Aspergillus versicolor and Penicillium chrysogenum spores in stage 1 of the sampler, which collects particles > 1.8 m m. Qian et al. (2012), using polycarbonate track-etched (PCTE) filters…”
InfluentialHwang, S., Park, D. U., & Yoon, C. (2018) · Human and Ecological Risk Assessment An International Journal · doi:10.1080/10807039.2018.1460578 · Cited by 4
“3)-b-D-glucan levels, there were a variety of available sampling methods (Yao et al. 2009), but we used a newly developed two-stage bioaerosol cyclone (BC) 221 sampler (Lindsley et al. 2006) with a firststage inlet diameter of 2 mm and a second-stage inlet diameter of 2.5 mm.”
MethodInfluentialA wind tunnel test of newly developed personal bioaerosol samplers
Su, W., Tolchinsky, A. D., Иванович, С. В., & Cheng, Y. S. (2012) · Journal of the Air & Waste Management Association · doi:10.1080/10962247.2012.681422 · Cited by 4
“researchers worldwide have designed various wet-type bioaerosol samplers to facilitate optimal bioaerosol sampling, and many of them have been sold on the market or presented to the academia, such as AGI-30, GCS, BioSampler, NIOSH onestage, NIOSH two-stage, CIP-10M, and the predecessors of the test samplers in this st…”
BackgroundLee, S.-A., Liao, C.-H., & Lin, T.-Y. (2018) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2017.08.0285 · Cited by 3
“The sampler’s detailed description and aerosol collection performance was stated in Lindsley et al. (2006).”
MethodLai, J., Sobhani, H., Coleman, K. K., Tai, S.-H. S., Hong, F. H., Maldonado, I. S., Esparza, Y., McPhaul, K. M., Zhu, S., DeVoe, D. L., et al. (2026) · PLoS Pathogens · doi:10.1371/journal.ppat.1013153 · Cited by 3
“…exposure events, we used a ceiling track system to position bioaerosol sampling devices developed by the National Institute for Occupational Safety and Health (NIOSH BC-251) [36] at sitting and standing breathing level heights (129 cm and 150 cm) in the designated exposure event room (Fig 1).”
PM2.5 detection by cyclone separator combined with SH-SAW sensor
Kuo, F.-Y., Wei, H.-L., & Yao, D. (2017) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2017.8017017 · Cited by 3
Collection and Extraction of Occupational Air Samples for Analysis of Fungal DNA
Lemons, A. R., Lindsley, W. G., & Green, B. J. (2018) · Journal of Visualized Experiments · doi:10.3791/56730 · Cited by 3
Self-citationGaseous and Particulate Content of Laser Tattoo Removal Plume
Levin, Y. S., Grant, M. P., Glassford, E. K., Green, B. J., Lemons, A. R., & Avram, M. M. (2021) · Dermatologic Surgery · doi:10.1097/dss.0000000000003089 · Cited by 3
Performance evaluation of a 3D-printed sharp-cut cyclone
Albanes, E., Bezantakos, S., Costi, M., & Biskos, G. (2022) · Environmental Science Processes & Impacts · doi:10.1039/d2em00089j · Cited by 2
Metadata
- Authors
- Lindsley, W. G., Schmechel, D., & Chen, B. T.
- Affiliations
- Centers for Disease Control and Prevention (US)
- Corresponding author
- Lindsley, William G.
- ORCID
- Lindsley, William G.
- Venue
- Journal of Environmental Monitoring
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2006
- Volume
- 8
- Issue
- 11
- Pages
- 1136
- ISSN
- 1464-0325 (ISSN-L)
- 1464-0333
- OpenAlex
- W1977029565
- Semantic Scholar
- 955956edced5de1a315f89a99d226d8d04b33fb7
- Cited by
- 117
- References
- 23
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 3 · 2023: 10 · 2022: 4 · 2021: 12 · 2020: 4 · 2019: 7 · 2018: 10 · 2017: 8 · 2016: 7 · 2015: 5 · 2014: 8 · 2013: 7 · 2012: 7
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Environmental Monitoring (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Computational Mechanics › Cyclone Separators and Fluid Dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Keywords
- microcentrifuge tubes, aerodynamic diameter, aspiration efficiency, fungal spores, Aspergillus versicolor, Penicillium chrysogenum, indoor air quality
- MeSH terms
- Aerosols, Bacteria, Centrifugation, Environmental Monitoring, Enzyme-Linked Immunosorbent Assay, Fungi, Humans, Particle Size, Spores, Fungal, Polymerase Chain Reaction, Occupational Exposure, Air Pollution, Indoor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.