The DOI matches its Crossref record.
High-density microfluidic arrays for cell cytotoxicity analysis
Abstract
In this paper, we report on the development of a multilayer elastomeric microfluidic array platform for the high-throughput cell cytotoxicity screening of mammalian cell lines. Microfluidic channels in the platform for cell seeding are orthogonal to channels for toxin exposure, and within each channel intersection is a circular chamber with cell-trapping sieves. Integrated, pneumatically-actuated elastomeric valves within the device isolate the microchannel array within the device into parallel rows and columns for cell seeding and toxin exposure. As a demonstration of the multiplexing capability of the platform, a microfluidic array containing 576 chambers was used to screen three cell types (BALB/3T3, HeLa, and bovine endothelial cells) against a panel of five toxins (digitonin, saponin, CoCl(2), NiCl(2), acrolein). Evaluation of on-chip cell morphology and viability was carried out using fluorescence microscopy, with outcomes comparable to microtiter plate cytotoxicity assays. Using this scalable platform, cell seeding and toxin exposure can be carried out within a single microfluidic device in a multiplexed format, enabling high-density parallel cytotoxicity screening while minimizing reagent consumption.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
A microfluidic device for a pharmacokinetic–pharmacodynamic (PK–PD) model on a chip
Sung, J. H., Kam, C., & Shuler, M. L. (2010) · Lab on a Chip · doi:10.1039/b917763a · Cited by 484
Micro Total Analysis Systems: Latest Achievements
West, J., Becker, M., Tombrink, S., & Manz, A. (2008) · Analytical Chemistry · doi:10.1021/ac800680j · Cited by 423
Cell Culture Models in Microfluidic Systems
Meyvantsson, I., & Beebe, D. J. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113042 · Cited by 345
Digital microfluidics for cell-based assays
Barbulovic-Nad, I., Yang, H., Park, P. S., & Wheeler, A. R. (2008) · Lab on a Chip · doi:10.1039/b717759c · Cited by 337
Metadata
- Authors
- Wang, Z., Kim, M.-C., Marquez, M., & Thorsen, T.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 6
- Pages
- 740
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2086428332
- Cited by
- 214
- References
- 0
- FWCI
- 13.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-density microfluidic arrays for cell cytotoxicity analysis. https://app.cochat.ai/papers/10.1039/b618734j
- The paper
- Wang, Z., Kim, M.-C., Marquez, M., & Thorsen, T. (2007). High-density microfluidic arrays for cell cytotoxicity analysis. Lab on a Chip. https://doi.org/10.1039/b618734j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.