Optical artefacts in transflection mode FTIR microspectroscopic images of single cells on a biological support: the effect of back-scattering into collection optics
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Infrared microspectroscopic imaging data of single human prostate cancer cells, on an artificial extracellular matrix (Matrigel) thin-film surface, are presented. The spectral intensity maps, obtained in reflection mode, appear to show that the protein intensity distribution observed at the location of a cell changes dramatically depending on the concentration and/or thickness of the underlying Matrigel layer. Specifically, cells adhered to a low protein concentration or thin surface exhibit a higher protein intensity signal than the surrounding layer whereas those on a high protein concentration or thick surface exhibit a lower protein intensity signal. These results are qualitatively explained by a simple model that takes into account the fact that radiation scattered from cells can enter the collection optics of the microscope without passing through the Matrigel layer. This leads to an apparent reduction in absorption at the cell.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basement membrane complexes with biological activity
Kleinman, H. K., McGarvey, M. L., Hassell, J. R., Star, V. L., Cannon, F. B., Laurie, G. W., & Martin, G. R. (1986) · Biochemistry · doi:10.1021/bi00350a005 · Cited by 1,502
Cited by
Bassan, P., Kohler, A., Martens, H., Lee, J., Byrne, H. J., Dumas, P., Gazi, E., Brown, M., Clarke, N., & Gardner, P. (2010) · The Analyst · doi:10.1039/b921056c · Cited by 375
Self-citationBassan, P., Byrne, H. J., Bonnier, F., Lee, J., Dumas, P., & Gardner, P. (2009) · The Analyst · doi:10.1039/b904808a · Cited by 316
Self-citationBassan, P., Lee, J., Sachdeva, A., Pissardini, J., Dorling, K. M., Fletcher, J. S., Henderson, A., & Gardner, P. (2013) · The Analyst · doi:10.1039/c2an36090j · Cited by 130
Self-citationElectric field standing wave artefacts in FTIR micro-spectroscopy of biological materials
Filik, J., Frogley, M. D., Pijanka, J. K., Wehbe, K., & Cinque, G. (2012) · The Analyst · doi:10.1039/c2an15995c · Cited by 122
Theory of Midinfrared Absorption Microspectroscopy: I. Homogeneous Samples
Davis, B. J., Carney, P. S., & Bhargava, R. (2010) · Analytical Chemistry · doi:10.1021/ac902067p · Cited by 115
van Dijk, T., Mayerich, D., Carney, P. S., & Bhargava, R. (2013) · Applied Spectroscopy · doi:10.1366/12-06847 · Cited by 55
Metadata
- Authors
- Lee, J., Gazi, E., Dwyer, J., Brown, M. D., Clarke, N. W., Nicholson, J. M., & Gardner, P.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 132
- Issue
- 8
- Pages
- 750
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2108578954
- Cited by
- 52
- References
- 1
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.