Gradient generation by an osmotic pump and the behavior of human mesenchymal stem cells under the fetal bovine serum concentration gradient
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper describes a method to generate a concentration gradient using an osmosis-driven pump, without the need for bulky peripheral devices, such as an electric syringe pump or a pneumatic pump. By the osmosis, the flow in the microfluidic channel can be controlled even to a very slow speed (nanolitre scale), which enables its application to generate the stable and wide (width = 4 mm) concentration gradient profile, even within a short flow path. A computational simulation was also performed to predict the local distribution of the solute concentration and velocity-pressure profile in the microfluidic chip. The performance of the osmosis-driven pump was evaluated by culturing human mesenchymal stem cells within the concentration gradient of fetal bovine serum. The effects of the gradient on attachment, viability and morphology of the cells were analyzed and quantified. The cell density in a higher serum concentration region was twice greater than that in the pure culture media. The compact, cost-effective, self-powered and osmosis-based gradient generation system can be useful for biomedical and chemical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A microfluidic multi-injector for gradient generation
Chung, B. G., Lin, F., & Jeon, N. L. (2006) · Lab on a Chip · doi:10.1039/b512667c · Cited by 104
Cited by
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Park, J., Lee, B. K., Jeong, G. S., Hyun, J. K., Lee, C. J., & Lee, S.-H. (2015) · Lab on a Chip · doi:10.1039/c4lc00962b · Cited by 350
Self-citationLee, S.-A., No, D. Y., Kang, E., Ju, J., Kim, D.-S., & Lee, S.-H. (2013) · Lab on a Chip · doi:10.1039/c3lc50197c · Cited by 297
Self-citationMoshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Flow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
Kang, S. G., Choi, Y. Y., Mo, S. J., Kim, T. H., Ha, J. H., Hong, D. K., Lee, H., Park, S. D., Shim, J.-J., Lee, J.-L., et al. (2023) · Nano Convergence · doi:10.1186/s40580-022-00350-6 · Cited by 37
Lee, G., Han, S.-B., Kim, S. H., Jeong, S., & Kim, D.-H. (2024) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2024.1303688 · Cited by 6
Metadata
- Authors
- Park, J. Y., Hwang, C. M., Lee, S. H., & Lee, S.-H.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2007
- Volume
- 7
- Issue
- 12
- Pages
- 1673
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2159245147
- Cited by
- 109
- References
- 1
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.