A membrane-based microfluidic device for controlling the flux of platelet agonists into flowing blood
Open accessThe DOI matches its Crossref record.
Abstract
The flux of platelet agonists into flowing blood is a critical event in thrombosis and hemostasis. However, few in vitro methods exist for examining and controlling the role of platelet agonists on clot formation and stability under hemodynamic conditions. In this paper, we describe a membrane-based method for introducing a solute into flowing blood at a defined flux. The device consisted of a track-etched polycarbonate membrane reversibly sealed between two microfluidic channels; one channel contained blood flowing at a physiologically relevant shear rate, and the other channel contained the agonist(s). An analytical model described the solute flux as a function of the membrane permeability and transmembrane pressure. The model was validated using luciferase as a model solute for transmembrane pressures of 50-400 Pa. As a proof-of-concept, the weak platelet agonist ADP was introduced into whole blood flowing at 250 s(-1) at three fluxes (1.5, 2.4, and 4.4 x 10(-18) mol microm(-2) s(-1)). Platelet aggregation was monitored by fluorescence microscopy during the experiment and the morphology of aggregates was determined by post hoc confocal and electron microscopy. At the lowest flux (1.5 x 10(-18) mol microm(-2) s(-1)), we observed little to no aggregation. At the higher fluxes, we observed monolayer (2.4 x 10(-18) mol microm(-2) s(-1)) and multilayer (4.4 x 10(-18) mol microm(-2) s(-1)) aggregates of platelets and found that the platelet density within an aggregate increased with increasing ADP flux. We expect this device to be a useful tool in unraveling the role of platelet agonists on clot formation and stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Westein, E., van der Meer, A. D., Kuijpers, M. J. E., Frimat, J.-P., van den Berg, A., & Heemskerk, J. W. M. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209905110 · Cited by 304
Welsh, J. D., Stalker, T. J., Voronov, R., Muthard, R. W., Tomaiuolo, M., Diamond, S. L., & Brass, L. F. (2014) · Blood · doi:10.1182/blood-2014-01-550335 · Cited by 185
“By comparison, ADP and especially TxA2 are freely diffusible.(9) Our goal in this study was to develop and apply methods to understand the relationship betweenmolecular transport, platelet packing density, and agonist distribution, examining how each affects platelet activation and thrombus growth in vivo.”
BackgroundSelf-citationIrreversible, direct bonding of nanoporous polymer membranes to PDMS or glass microdevices
Aran, K., Sasso, L. A., Kamdar, N., & Zahn, J. D. (2010) · Lab on a Chip · doi:10.1039/b924816a · Cited by 159
Mondrinos, M. J., Yi, Y.-S., Wu, N.-K., Ding, X., & Huh, D. (2017) · Lab on a Chip · doi:10.1039/c7lc00317j · Cited by 95
Metadata
- Authors
- Neeves, K. B., & Diamond, S. L.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 5
- Pages
- 701
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2077595268
- Cited by
- 84
- References
- 0
- FWCI
- 5.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A membrane-based microfluidic device for controlling the flux of platelet agonists into flowing blood. https://app.cochat.ai/papers/10.1039/b717824g
- The paper
- Neeves, K. B., & Diamond, S. L. (2008). A membrane-based microfluidic device for controlling the flux of platelet agonists into flowing blood. Lab on a Chip. https://doi.org/10.1039/b717824g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.