Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 304

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Atherosclerotic geometries exacerbate pathological thrombus formation poststenosis in a von Willebrand factor-dependent manner

Open access
Westein, Erik, van der Meer, Andries D., Kuijpers, Marijke J. E., Frimat, Jean-Philippe, van den Berg, Albert, Heemskerk, Johan W. M. · 2013 · Proceedings of the National Academy of Sciences

Abstract

Rupture of a vulnerable atherosclerotic plaque causes thrombus formation and precipitates cardiovascular diseases. In addition to the thrombogenic content of a plaque, also the hemodynamic microenvironment plays a major role in thrombus formation. How the altered hemodynamics around a plaque promote pathological thrombus formation is not well understood. In this study, we provide evidence that plaque geometries result in fluid mechanical conditions that promote platelet aggregation and thrombus formation by increased accumulation and activity of von Willebrand factor (vWF) at poststenotic sites. Resonant-scanning multiphoton microscopy revealed that in vivo arterial stenosis of a damaged carotid artery markedly increased platelet aggregate formation in the stenotic outlet region. Complementary in vitro studies using microfluidic stenotic chambers, designed to mimic the flow conditions in a stenotic artery, showed enhanced platelet aggregation in the stenotic outlet region at 60–80% channel occlusion over a range of input wall shear rates. The poststenotic thrombus formation was critically dependent on bloodborne vWF and autocrine platelet stimulation. In stenotic chambers containing endothelial cells, flow provoked increased endothelial vWF secretion in the stenotic outlet region, contributing to exacerbated platelet aggregation. Taken together, this study identifies a role for the shear-sensitive protein vWF in transducing hemodynamic forces that are present around a stenosis to a prothrombogenic microenvironment resulting in spatially confined and exacerbated platelet aggregation in the stenosis outlet region. The developed stenotic microfluidic chamber offers a realistic platform for in vitro evaluation of shear-dependent thrombus formation in the setting of atherosclerosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.1209905110

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 304

Metadata

Authors
Westein, E., van der Meer, A. D., Kuijpers, M. J. E., Frimat, J.-P., van den Berg, A., & Heemskerk, J. W. M.
Venue
Proceedings of the National Academy of Sciences
Published
2013-01-03
Volume
110
Issue
4
Pages
1357-1362
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2127202845
Cited by
304
References
31
FWCI
13.65
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Atherosclerotic geometries exacerbate pathological thrombus formation poststenosis in a von Willebrand factor-dependent manner. https://app.cochat.ai/papers/10.1073/pnas.1209905110
The paper
Westein, E., van der Meer, A. D., Kuijpers, M. J. E., Frimat, J.-P., van den Berg, A., & Heemskerk, J. W. M. (2013). Atherosclerotic geometries exacerbate pathological thrombus formation poststenosis in a von Willebrand factor-dependent manner. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1209905110

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.