The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Glass coating for PDMS microfluidic channels by sol–gel methods
Abstract
Soft lithography using polydimethylsiloxane (PDMS) allows one to fabricate complex microfluidic devices easily and at low cost. However, PDMS swells in the presence of many organic solvents significantly degrading the performance of the device. We present a method to coat PDMS channels with a glass-like layer using sol-gel chemistry. This coating greatly increases chemical resistance of the channels; moreover, it can be functionalized with a wide range of chemicals to precisely control interfacial properties. This method combines the ease of fabrication afforded by soft-lithography with the precision control and chemical robustness afforded by glass.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Solvent-Resistant Photocurable “Liquid Teflon” for Microfluidic Device Fabrication
Rolland, J. P., Van Dam, R. M., Schorzman, D. A., Quake, S. R., & DeSimone, J. M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031657y · Cited by 440
Microfluidic consecutive flow-focusing droplet generators
Seo, M., Paquet, C., Nie, Z., Xu, S., & Kumacheva, E. (2007) · Soft Matter · doi:10.1039/b700687j · Cited by 263
Roman, G. T., Hlaus, T., Bass, K. J., Seelhammer, T. G., & Culbertson, C. T. (2005) · Analytical Chemistry · doi:10.1021/ac048811z · Cited by 223
Roman, G. T., & Culbertson, C. T. (2006) · Langmuir · doi:10.1021/la053085w · Cited by 131
Estella, J., Echeverría, J. C., Laguna, M., & Garrido, J. J. (2007) · Journal of Non-Crystalline Solids · doi:10.1016/j.jnoncrysol.2006.12.006 · Cited by 80
Surface Modification of Poly(dimethylsiloxane) for Retarding Swelling in Organic Solvents
Lee, J. Y., Kim, M., & Lee, H. H. (2006) · Langmuir · doi:10.1021/la052621h · Cited by 52
Materials for Micro- and Nanofluidics
Kenis, P. J. A., & Stroock, A. D. (2006) · MRS Bulletin · doi:10.1557/mrs2006.21 · Cited by 21
Cited by
Cambié, D., Bottecchia, C., Straathof, N. J. W., Hessel, V., & Noël, T. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00707 · Cited by 1,502
The past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Recent developments in PDMS surface modification for microfluidic devices
Zhou, J., Ellis, A. V., & Voelcker, N. H. (2010) · ELECTROPHORESIS · doi:10.1002/elps.200900475 · Cited by 857
Metadata
- Authors
- Abate, A. R., Lee, D., Do, T., Holtze, C., & Weitz, D. A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 4
- Pages
- 516
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2154856902
- Cited by
- 318
- References
- 12
- FWCI
- 15.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.