Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Cross-scale electric manipulations of cells and droplets by frequency-modulated dielectrophoresis and electrowetting

Fan, Shih-Kang, Huang, Po-Wen, Wang, Tsu-Te, Peng, Yu-Hao·2008·Lab on a Chip

Abstract

Two important electric forces, dielectrophoresis (DEP) and electrowetting-on-dielectric (EWOD), are demonstrated by dielectric-coated electrodes on a single chip to manipulate objects on different scales, which results in a dielectrophoretic concentrator in an EWOD-actuated droplet. By applying appropriate electric signals with different frequencies on identical electrodes, EWOD and DEP can be selectively generated on the proposed chip. At low frequencies, the applied voltage is consumed mostly in the dielectric layer and causes EWOD to pump liquid droplets on the millimetre scale. However, high frequency signals establish electric fields in the liquid and generate DEP forces to actuate cells or particles on the micrometre scale inside the droplet. For better performance of EWOD and DEP, square and strip electrodes are designed, respectively. Mammalian cells (Neuro-2a) and polystyrene beads are successfully actuated by a 2 MHz signal in a droplet by positive DEP and negative DEP, respectively. Droplet splitting is achieved by EWOD with a 1 kHz signal after moving cells or beads to one side of the droplet. Cell concentration, measured by a cell count chamber before and after experiments, increases 1.6 times from 8.6 x 10(5) cells ml(-1) to 1.4 x 10(6) cells ml(-1) with a single cycle of positive DEP attraction. By comparing the cutoff frequency of the voltage drop in the dielectric layer and the cross-over frequency of Re(fCM) of the suspended particles, we can estimate the frequency-modulated behaviors between EWOD, positive DEP, and negative DEP. A proposed weighted Re(fCM) facilitates analysis of the DEP phenomenon on dielectric-coated electrodes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/b803204a

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 167

Metadata

Authors
Fan, S.-K., Huang, P.-W., Wang, T.-T., & Peng, Y.-H.
Venue
Lab on a Chip
Published
2008
Volume
8
Issue
8
Pages
1325
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2092656565
Cited by
167
References
2
FWCI
10.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cross-scale electric manipulations of cells and droplets by frequency-modulated dielectrophoresis and electrowetting. https://app.cochat.ai/papers/10.1039/b803204a
The paper
Fan, S.-K., Huang, P.-W., Wang, T.-T., & Peng, Y.-H. (2008). Cross-scale electric manipulations of cells and droplets by frequency-modulated dielectrophoresis and electrowetting. Lab on a Chip. https://doi.org/10.1039/b803204a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.