Microfluidic devices for studies of shear-dependent platelet adhesion
Open accessThe DOI matches its Crossref record.
Abstract
Adhesion of platelets to blood vessel walls is a shear stress dependent process that promotes arrest of bleeding and is mediated by the interaction of receptors expressed on platelets with various extracellular matrix (ECM) proteins that may become exposed upon vascular injury. Studies of dynamic platelet adhesion to ECM-coated substrates in conventional flow chambers require substantial fluid volumes and are difficult to perform with blood samples from a single laboratory mouse. Here we report dynamic platelet adhesion assays in two new microfluidic devices made of PDMS. Small cross-sections of the flow chambers in the devices reduce the blood volume requirements to <100 microl per assay, making the assays compatible with samples of whole blood obtained from a single mouse. One device has an array of 8 flow chambers with shear stress varying by a factor of 1.93 between adjacent chambers, covering a 100-fold range from low venous to arterial. The other device allows simultaneous high-resolution fluorescence imaging of dynamic adhesion of platelets from two different blood samples. Adhesion of platelets in the devices to three common ECM substrate coatings was verified to conform with published results. The devices were subsequently used to study the roles of extracellular and intracellular domains of integrin alphaIIbbeta3, a platelet receptor that is a central mediator of platelet aggregation and thrombus formation. The study involved wild-type mice and two genetically modified mouse strains and showed that the absence of the integrin impaired adhesion at all shear stresses, whereas a mutation in its intracellular domain reduced the adhesion only at moderate and high stresses. Because of small sample volumes required, the devices could be employed in research with genetically-modified model organisms and for adhesion tests in clinical settings with blood from neonates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Microfluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272
Shin, M. K., Kim, S. K., & Jung, H. (2011) · Lab on a Chip · doi:10.1039/c1lc20671k · Cited by 94
Chen, Z., Lu, J., Zhang, C., Hsia, I., Yu, X., Marecki, L., Marecki, E., Asmani, M., Jain, S., Neelamegham, S., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10067-6 · Cited by 64
Monitoring in vitro thrombus formation with novel microfluidic devices
Westein, E., de Witt, S., Lamers, M., Cosemans, J. M. E. M., & Heemskerk, J. W. M. (2012) · Platelets · doi:10.3109/09537104.2012.709653 · Cited by 54
“With this device the shear-dependent contributions of intracellular and extracellular domains of platelet IIb 3 were determined [24].”
Background
Metadata
- Authors
- Gutierrez, E., Petrich, B. G., Shattil, S. J., Ginsberg, M. H., Groisman, A., & Kasirer-Friede, A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 9
- Pages
- 1486
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2027234515
- Cited by
- 148
- References
- 0
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.