The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Biocompatible surfactants for water-in-fluorocarbon emulsions
Open accessAbstract
Drops of water-in-fluorocarbon emulsions have great potential for compartmentalizing both in vitro and in vivo biological systems; however, surfactants to stabilize such emulsions are scarce. Here we present a novel class of fluorosurfactants that we synthesize by coupling oligomeric perfluorinated polyethers (PFPE) with polyethyleneglycol (PEG). We demonstrate that these block copolymer surfactants stabilize water-in-fluorocarbon oil emulsions during all necessary steps of a drop-based experiment including drop formation, incubation, and reinjection into a second microfluidic device. Furthermore, we show that aqueous drops stabilized with these surfactants can be used for in vitro translation (IVT), as well as encapsulation and incubation of single cells. The compatability of this emulsion system with both biological systems and polydimethylsiloxane (PDMS) microfluidic devices makes these surfactants ideal for a broad range of high-throughput, drop-based applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lipinski, C. A., Lombardo, F., Dominy, B. W., & Feeney, P. J. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00129-0 · Cited by 18,139
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
In vivo quantification of spatially varying mechanical properties in developing tissues
Serwane, F., Mongera, A., Rowghanian, P., Kealhofer, D. A., Lucio, A. A., Hockenbery, Z. M., & Campàs, O. (2017) · Nature Methods · doi:10.1038/nmeth.4101 · Cited by 367
Droplet microfluidics: recent developments and future applications
Casadevall i Solvas, X., & deMello, A. (2011) · Chem. Commun. · doi:10.1039/c0cc02474k · Cited by 353
Metadata
- Authors
- Holtze, C., Rowat, A. C., Agresti, J. J., Hutchison, J. B., Angilè, F. E., Schmitz, C. H. J., Köster, S., Duan, H., Humphry, K. J., Scanga, R. A., Johnson, J. S., Pisignano, D., & Weitz, D. A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 10
- Pages
- 1632
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2152249986
- Cited by
- 670
- References
- 2
- FWCI
- 19.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biocompatible surfactants for water-in-fluorocarbon emulsions. https://app.cochat.ai/papers/10.1039/b806706f
- The paper
- Holtze, C., Rowat, A. C., Agresti, J. J., Hutchison, J. B., Angilè, F. E., Schmitz, C. H. J., Köster, S., Duan, H., Humphry, K. J., Scanga, R. A., Johnson, J. S., Pisignano, D., & Weitz, D. A. (2008). Biocompatible surfactants for water-in-fluorocarbon emulsions. Lab on a Chip. https://doi.org/10.1039/b806706f
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.