The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Biocompatible surfactants for water-in-fluorocarbon emulsions
Open accessAbstract
Drops of water-in-fluorocarbon emulsions have great potential for compartmentalizing both in vitro and in vivo biological systems; however, surfactants to stabilize such emulsions are scarce. Here we present a novel class of fluorosurfactants that we synthesize by coupling oligomeric perfluorinated polyethers (PFPE) with polyethyleneglycol (PEG). We demonstrate that these block copolymer surfactants stabilize water-in-fluorocarbon oil emulsions during all necessary steps of a drop-based experiment including drop formation, incubation, and reinjection into a second microfluidic device. Furthermore, we show that aqueous drops stabilized with these surfactants can be used for in vitro translation (IVT), as well as encapsulation and incubation of single cells. The compatability of this emulsion system with both biological systems and polydimethylsiloxane (PDMS) microfluidic devices makes these surfactants ideal for a broad range of high-throughput, drop-based applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lipinski, C. A., Lombardo, F., Dominy, B. W., & Feeney, P. J. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00129-0 · Cited by 18,139
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Polymeric stabilization of colloidal dispersions
Napper, D. H. (1983) · Medical Entomology and Zoology · Cited by 2,279
Alexandridis, P., & Alan Hatton, T. (1995) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/0927-7757(94)03028-x · Cited by 1,920
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Protein—surface interactions in the presence of polyethylene oxide
Jeon, S. I., Lee, J. H., Andrade, J. D., & De Gennes, P. G. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90043-8 · Cited by 1,523
Poly(ethylene glycol) chemistry : biotechnical and biomedical applications
Harris, J. M. (1992) · Plenum Press eBooks · Cited by 1,426
Gas sorption, diffusion, and permeation in poly(dimethylsiloxane)
Merkel, T. C., Bondar, V. I., Nagai, K., Freeman, B. D., & Pinnau, I. (2000) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/(sici)1099-0488(20000201)38:3<415::aid-polb8>3.0.co;2-z · Cited by 1,178
Protein adsorption and materials biocompatibility: A tutorial review and suggested hypotheses
Andrade, J. D., & Hlady, V. (1986) · Advances in Polymer Science · doi:10.1007/3-540-16422-7_6 · Cited by 810
Applied Surfactants: Principles and Applications
Tadros, T. F. (2005) · Medical Entomology and Zoology · Cited by 649
Dispersion Polymerization in Organic Media
Barrett, K. E. J. (1975) · Medical Entomology and Zoology · Cited by 635
Marcy, Y., Ouverney, C., Bik, E. M., Lösekann, T., Ivanova, N., Martin, H. G., Szeto, E., Platt, D., Hugenholtz, P., Relman, D. A., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704662104 · Cited by 634
He, M., Edgar, J. S., Jeffries, G. D. M., Lorenz, R. M., Shelby, J. P., & Chiu, D. T. (2005) · Analytical Chemistry · doi:10.1021/ac0480850 · Cited by 518
Drop-based microfluidic devices for encapsulation of single cells
Köster, S., Angilè, F. E., Duan, H., Agresti, J. J., Wintner, A., Schmitz, C., Rowat, A. C., Merten, C. A., Pisignano, D., Griffiths, A. D., et al. (2008) · Lab on a Chip · doi:10.1039/b802941e · Cited by 518
Self-citationStrategy-Level Separations in Organic Synthesis: From Planning to Practice
Curran, D. P. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980518)37:9<1174::aid-anie1174>3.0.co;2-p · Cited by 485
Chemistry of organic fluorine compounds
Hudlický, M. (1961) · Medical Entomology and Zoology · Cited by 474
Studer, A., Hadida, S., Ferritto, R., Kim, S.-Y., Jeger, P., Wipf, P., & Curran, D. P. (1997) · Science · doi:10.1126/science.275.5301.823 · Cited by 470
Decompressing Emulsion Droplets Favors Coalescence
Bremond, N., Thiam, A. R., & Bibette, J. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.024501 · Cited by 413
Effects of viscosity on droplet formation and mixing in microfluidic channels
Tice, J. D., Lyon, A. D., & Ismagilov, R. F. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.11.024 · Cited by 360
Miniaturising the laboratory in emulsion droplets
Griffiths, A. D., & Tawfik, D. S. (2006) · Trends in Biotechnology · doi:10.1016/j.tibtech.2006.06.009 · Cited by 346
Fluorous micro- and nanophases with a biomedical perspective
Riess, J. G. (2002) · Tetrahedron · doi:10.1016/s0040-4020(02)00262-4 · Cited by 289
Nanoliter Reactors Improve Multiple Displacement Amplification of Genomes from Single Cells
Marcy, Y., Ishoey, T., Lasken, R. S., Stockwell, T. B., Walenz, B. P., Halpern, A. L., Beeson, K. Y., Goldberg, S. M. D., & Quake, S. R. (2007) · PLoS Genetics · doi:10.1371/journal.pgen.0030155 · Cited by 286
Stability of emulsions under equilibrium and dynamic conditions
Ivanov, I. B., & Kralchevsky, P. A. (1997) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/s0927-7757(96)03903-9 · Cited by 227
Mastrobattista, E., Taly, V., Chanudet, E., Treacy, P., Kelly, B. T., & Griffiths, A. D. (2005) · Chemistry & Biology · doi:10.1016/j.chembiol.2005.09.016 · Cited by 222
XPS and AFM analysis of antifouling PEG interfaces for microfabricated silicon biosensors
Sharma, S., Johnson, R. W., & Desai, T. A. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.01.034 · Cited by 198
Miniaturizing chemistry and biology in microdroplets
Kelly, B. T., Baret, J.-C., Taly, V., & Griffiths, A. D. (2007) · Chemical Communications · doi:10.1039/b616252e · Cited by 197
Flocculation and coalescence of micron-size emulsion droplets
Ivanov, I. B., Danov, K. D., & Kralchevsky, P. A. (1999) · Colloids and Surfaces A: Physicochemical and Engineering Aspects · doi:10.1016/s0927-7757(98)00620-7 · Cited by 163
Perfluorochemical respiratory gas carriers: benefits to cell culture systems
Lowe, K. C. (2002) · Journal of Fluorine Chemistry · doi:10.1016/s0022-1139(02)00200-2 · Cited by 125
The Solubility of Fluorocarbons1
Scott, R. L. (1948) · Journal of the American Chemical Society · doi:10.1021/ja01192a036 · Cited by 106
Emulsions and microemulsions with a fluorocarbon phase
Krafft, M. P. (2003) · Current Opinion in Colloid & Interface Science · doi:10.1016/s1359-0294(03)00045-1 · Cited by 82
Achieving Stable, Reverse Water‐in‐Fluorocarbon Emulsions
Sadtler, V., Krafft, M. P., & Riess, J. G. (1996) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199619761 · Cited by 61
Zhu, S., Edmonds, W. F., Hillmyer, M. A., & Lodge, T. P. (2005) · Journal of Polymer Science Part B Polymer Physics · doi:10.1002/polb.20621 · Cited by 35
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Spontaneous motion in hierarchically assembled active matter
Sanchez, T., Chen, D. T. N., DeCamp, S. J., Heymann, M., & Dogic, Z. (2012) · Nature · doi:10.1038/nature11591 · Cited by 1,415
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Self-citationUltrahigh-throughput screening in drop-based microfluidics for directed evolution
Agresti, J. J., Antipov, E., Abate, A. R., Ahn, K., Rowat, A. C., Baret, J.-C., Marquez, M., Klibanov, A. M., Griffiths, A. D., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910781107 · Cited by 1,149
Self-citation
Metadata
- Authors
- Holtze, C., Rowat, A. C., Agresti, J. J., Hutchison, J. B., Angilè, F. E., Schmitz, C. H. J., Köster, S., Duan, H., Humphry, K. J., Scanga, R. A., Johnson, J. S., Pisignano, D., & Weitz, D. A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 10
- Pages
- 1632
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2152249986
- Cited by
- 670
- References
- 35
- FWCI
- 19.40
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.