A microdevice for multiplexed detection of T-cell-secreted cytokines
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Cytokines are produced by immune cells in response to viral or bacterial pathogens and therefore have significant diagnostic value. The goal of the present study was to develop a miniature device for detection of interleukin (IL)-2 and interferon (IFN)-gamma cytokines secreted by a small population of CD4 and CD8 T-cells. Microarrays of T-cell- and cytokine-specific Ab spots were printed onto poly(ethylene glycol) (PEG) hydrogel-coated glass slides and enclosed inside a microfluidic device, creating a miniature ( approximately 3 microL) immunoreaction chamber. Introduction of the red blood cell (RBC) depleted whole human blood into the microfluidic device followed by washing at a pre-defined shear stress resulted in isolation of pure CD4 and CD8 T-cells on their respective Ab spots. Importantly, the cells became localized next to anti-IL-2 and -IFN-gamma Ab spots. Mitogenic activation of the captured T-cells was followed by immunofluorescent staining (all steps carried out inside a microfluidic device), revealing concentration gradients of surface-bound cytokine molecules. A microarray scanner was then used to quantify the concentration of IFN-gamma and IL-2 near CD4 and CD8 T-cells. This study represents one of the first demonstrations of a microdevice for capturing desired T-cell subsets from a small blood volume and determining, on-chip, cytokine profiles of the isolated cells. Such a microdevice is envisioned as an immunology tool for multi-parametric analysis of T-cell function with direct applications in diagnosis/monitoring of HIV and other infectious diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Printing Proteins as Microarrays for High-Throughput Function Determination
MacBeath, G., & Schreiber, S. L. (2000) · Science · doi:10.1126/science.289.5485.1760 · Cited by 2,767
Cited by
Using personal glucose meters and functional DNA sensors to quantify a variety of analytical targets
Xiang, Y., & Lu, Y. (2011) · Nature Chemistry · doi:10.1038/nchem.1092 · Cited by 677
Kartikasari, A. E. R., Huertas, C. S., Mitchell, A., & Plebanski, M. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.692142 · Cited by 343
Aptamer-Based Electrochemical Biosensor for Interferon Gamma Detection
Liu, Y., Tuleouva, N., Ramanculov, E., & Revzin, A. (2010) · Analytical Chemistry · doi:10.1021/ac101409t · Cited by 324
Self-citationBioanalytical Chemistry of Cytokines–a Review
Stenken, J. A., & Poschenrieder, A. J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.10.009 · Cited by 302
Microfluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
Metadata
- Authors
- Zhu, H., Stybayeva, G., Macal, M., Ramanculov, E., George, M. D., Dandekar, S., & Revzin, A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 12
- Pages
- 2197
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2014357898
- Cited by
- 98
- References
- 1
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microdevice for multiplexed detection of T-cell-secreted cytokines. https://app.cochat.ai/papers/10.1039/b810244a
- The paper
- Zhu, H., Stybayeva, G., Macal, M., Ramanculov, E., George, M. D., Dandekar, S., & Revzin, A. (2008). A microdevice for multiplexed detection of T-cell-secreted cytokines. Lab on a Chip. https://doi.org/10.1039/b810244a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.