The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Innovations in optical microfluidic technologies for point-of-care diagnostics
Abstract
Despite a growing focus from the academic community, the field of microfluidics has yet to produce many commercial devices for point-of-care (POC) diagnostics. One of the main reasons for this is the difficulty in producing low-cost, sensitive, and portable optical detection systems. Although electrochemical methods work well for certain applications, optical detection is generally regarded as superior and is the method most widely employed in laboratory clinical chemistry. Conventional optical systems, however, are costly, require careful alignment, and do not translate well to POC devices. Furthermore, many optical detection paradigms such as absorbance and fluorescence suffer at smaller geometries because the optical path length through the sample is shortened. This review examines the innovative techniques which have recently been developed to address these issues. We highlight microfluidic diagnostic systems which demonstrate practical integration of sample preparation, analyte enrichment, and optical detection. We also examine several emerging detection paradigms involving nanoengineered materials which do not suffer from the same miniaturization disadvantages as conventional measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Raman spectra of pyridine adsorbed at a silver electrode
Fleischmann, M., Hendra, P. J., & McQuillan, A. J. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)85388-1 · Cited by 7,172
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
Localized Surface Plasmon Resonance Spectroscopy and Sensing
Willets, K. A., & Van Duyne, R. P. (2007) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.58.032806.104607 · Cited by 6,171
Haynes, C. L., & Van Duyne, R. P. (2001) · The Journal of Physical Chemistry B · doi:10.1021/jp010657m · Cited by 2,500
Nanostructured Plasmonic Sensors
Stewart, M. E., Anderton, C. R., Thompson, L. B., Maria, J., Gray, S. K., Rogers, J. A., & Nuzzo, R. G. (2008) · Chemical Reviews · doi:10.1021/cr068126n · Cited by 2,415
Scanometric DNA Array Detection with Nanoparticle Probes
Taton, T. A., Mirkin, C. A., & Letsinger, R. L. (2000) · Science · doi:10.1126/science.289.5485.1757 · Cited by 2,411
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,390
Nanoparticle-Based Bio-Barcodes for the Ultrasensitive Detection of Proteins*
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2020) · Spherical Nucleic Acids · doi:10.1201/9781003056713-94 · Cited by 2,035
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Angle-multiplexed all-dielectric metasurfaces for broadband molecular fingerprint retrieval
Leitis, A., Tittl, A., Liu, M., Lee, B. H., Gu, M. B., Kivshar, Y. S., & Altug, H. (2019) · Science Advances · doi:10.1126/sciadv.aaw2871 · Cited by 542
A review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
Advances in Plasmonic Technologies for Point of Care Applications
Tokel, O., Inci, F., & Demirci, U. (2014) · Chemical Reviews · doi:10.1021/cr4000623 · Cited by 407
Use of multiple colorimetric indicators for paper-based microfluidic devices
Dungchai, W., Chailapakul, O., & Henry, C. S. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.06.019 · Cited by 364
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Nano/Microfluidics for diagnosis of infectious diseases in developing countries
Lee, W. G., Kim, Y.-G., Chung, B. G., Demirci, U., & Khademhosseini, A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.016 · Cited by 357
Handheld high-throughput plasmonic biosensor using computational on-chip imaging
Cetin, A. E., Coskun, A. F., Galarreta, B. C., Huang, M., Herman, D., Ozcan, A., & Altug, H. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.3 · Cited by 354
Droplet microfluidics: recent developments and future applications
Casadevall i Solvas, X., & deMello, A. (2011) · Chem. Commun. · doi:10.1039/c0cc02474k · Cited by 353
Point-of-care biochemical assays using gold nanoparticle-implemented microfluidics
Sun, J., Xianyu, Y., & Jiang, X. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00125g · Cited by 323
Pires, N., Dong, T., Hanke, U., & Hoivik, N. (2014) · Sensors · doi:10.3390/s140815458 · Cited by 307
Mohammed, M.-I., & Desmulliez, M. P. Y. (2011) · Lab Chip · doi:10.1039/c0lc00204f · Cited by 304
Recent Developments in Magnetic Diagnostic Systems
Lee, H., Shin, T.-H., Cheon, J., & Weissleder, R. (2015) · Chemical Reviews · doi:10.1021/cr500698d · Cited by 292
Fang, X., Liu, Y., Kong, J., & Jiang, X. (2010) · Analytical Chemistry · doi:10.1021/ac1000652 · Cited by 292
Heidt, B., Siqueira, W., Eersels, K., Diliën, H., van Grinsven, B., Fujiwara, R., & Cleij, T. (2020) · Biosensors · doi:10.3390/bios10100133 · Cited by 260
Metadata
- Authors
- Myers, F. B., & Lee, L. P.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2008
- Volume
- 8
- Issue
- 12
- Pages
- 2015
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2115910755
- Cited by
- 474
- References
- 69
- FWCI
- 20.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.