Generalized serial dilution module for monotonic and arbitrary microfluidic gradient generators
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this paper, we propose a generalized serial dilution module for universal microfluidic concentration gradient generators including N cascaded-mixing stages in a stepwise manner. Desired concentrations were generated by means of controlled volumetric mixing ratios of two merging solutions in each stage. The flow rates were adjusted by controlling channel length, which is proportional to fluidic resistance in each channel. A generalized mathematical model for generating any complex concentration and output flow rate gradients is presented based on the fact that there is an analogy between microfluidic circuits and electrical circuits. The pressure drop corresponds to a voltage drop, the flow rate to an electrical current, and the flow resistance to an electrical resistance. A simple equivalent electrical circuit model was generalized, and in the model each channel segment was represented by an electrical resistance. As a result of the mathematical modelling, the only variable parameter in the generalized serial dilution module was the channel length. By the use of the generalized serial dilution module with N = 4, three types of microfluidic gradient generators for linear, logarithmic and Gaussian gradients were successfully designed and tested. The proposed strategy is capable of generating universal monotonic gradients with a single module or arbitrary gradients with multiple modules ranging from linear to complex non-linear shapes of concentration gradients as well as arbitrary output flow rate gradients in a stepwise manner. The simple universal gradient generation technology using the generalized serial dilution module will find widespread use in the greater chemical and biological community, and address many challenges of gradient-dependent phenomena.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cancer and the chemokine network
Balkwill, F. (2004) · Nature Reviews Cancer · doi:10.1038/nrc1388 · Cited by 2,343
Biomolecular gradients in cell culture systems
Keenan, T. M., & Folch, A. (2008) · Lab Chip · doi:10.1039/b711887b · Cited by 596
Cited by
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Self-citationLatest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Stephenson, W., Donlin, L. T., Butler, A., Rozo, C., Bracken, B., Rashidfarrokhi, A., Goodman, S. M., Ivashkiv, L. B., Bykerk, V. P., Orange, D. E., et al. (2018) · Nature Communications · doi:10.1038/s41467-017-02659-x · Cited by 365
Biomimetic gradient hydrogels for tissue engineering
Sant, S., Hancock, M. J., Donnelly, J. P., Iyer, D., & Khademhosseini, A. (2010) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.20411 · Cited by 253
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Metadata
- Authors
- Lee, K., Kim, C., Ahn, B., Panchapakesan, R., Full, A. R., Nordee, L., Kang, J. Y., & Oh, K. W.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 5
- Pages
- 709-717
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2024447195
- Cited by
- 145
- References
- 2
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Generalized serial dilution module for monotonic and arbitrary microfluidic gradient generators. https://app.cochat.ai/papers/10.1039/b813582g
- The paper
- Lee, K., Kim, C., Ahn, B., Panchapakesan, R., Full, A. R., Nordee, L., Kang, J. Y., & Oh, K. W. (2009). Generalized serial dilution module for monotonic and arbitrary microfluidic gradient generators. Lab Chip. https://doi.org/10.1039/b813582g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.