A fluidic device to study directional angiogenesis in complex tissue and organ culture models
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Many signals that induce angiogenesis have been identified; however, it is still not clear how these signals interact to shape the vascular system. We have developed a fluidic device for generation of molecular gradients in 3-dimensional cultures of complex tissues and organs in order to create an assay for precise induction and guidance of growing blood vessels. The device features a centrally placed culture chamber, flanked by channels attached to a perfusion system used to generate gradients. A separate network of vacuum channels permits reversible attachment of the device to a flat surface. We show that the fluidic device can be used to create growth factor gradients that induce directional angiogenesis in embryonic mouse kidneys and in clusters of differentiating stem cells. These results demonstrate that the device can be used to accurately manipulate complex morphogenetic processes with a high degree of experimental control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
VEGF receptor signalling ? in control of vascular function
Olsson, A.-K., Dimberg, A., Kreuger, J., & Claesson-Welsh, L. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1911 · Cited by 3,122
Self-citationVEGF guides angiogenic sprouting utilizing endothelial tip cell filopodia
Gerhardt, H., Golding, M., Fruttiger, M., Ruhrberg, C., Lundkvist, A., Abramsson, A., Jeltsch, M., Mitchell, C., Alitalo, K., Shima, D., et al. (2003) · The Journal of Cell Biology · doi:10.1083/jcb.200302047 · Cited by 2,894
Modeling Tissue Morphogenesis and Cancer in 3D
Yamada, K. M., & Cukierman, E. (2007) · Cell · doi:10.1016/j.cell.2007.08.006 · Cited by 1,751
Turning of nerve growth cones induced by neurotransmitters
Zheng, J. Q., Felder, M., Connor, J. A., & Poo, M.-M. (1994) · Nature · doi:10.1038/368140a0 · Cited by 580
Cited by
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
“, angiogenesis in patients with tumors, diabetes or with wounds (47), or to study the effects of inflammation on vascular integrity or interrupt flow, e.”
BackgroundIn vitro spatially organizing the differentiation in individual multicellular stem cell aggregates
Qi, H., Huang, G., Han, Y. L., Lin, W., Li, X., Wang, S., Lu, T. J., & Xu, F. (2016) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2014.922917 · Cited by 26
“The temperature gradient can be used as a powerful tool to study the spatial anterior-posterior formation in the Drosophila embryo (Figure 5C and D; Barkefors et al., 2009).”
BackgroundMethodInfluential
Metadata
- Authors
- Barkefors, I., Thorslund, S., Nikolajeff, F., & Kreuger, J.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 4
- Pages
- 529-535
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2164648069
- Cited by
- 48
- References
- 4
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A fluidic device to study directional angiogenesis in complex tissue and organ culture models. https://app.cochat.ai/papers/10.1039/b814691h
- The paper
- Barkefors, I., Thorslund, S., Nikolajeff, F., & Kreuger, J. (2009). A fluidic device to study directional angiogenesis in complex tissue and organ culture models. Lab Chip. https://doi.org/10.1039/b814691h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.