A portable cell-based impedance sensor for toxicity testing of drinking water
The DOI matches its Crossref record.
Abstract
A major limitation to using mammalian cell-based biosensors for field testing of drinking water samples is the difficulty of maintaining cell viability and sterility without an on-site cell culture facility. This paper describes a portable automated bench-top mammalian cell-based toxicity sensor that incorporates enclosed fluidic biochips containing endothelial cells monitored by Electric Cell-substrate Impedance Sensing (ECIS) technology. Long-term maintenance of cells on the biochips is made possible by using a compact, self-contained disposable media delivery system. The toxicity sensor monitors changes in impedance of cell monolayers on the biochips after the introduction of water samples. The fluidic biochip includes an ECIS electronic layer and a polycarbonate channel layer, which together reduce initial impedance disturbances seen in commercially available open well ECIS chips caused by the mechanics of pipetting while maintaining the ability of the cells to respond to toxicants. A curve discrimination program was developed that compares impedance values over time between the control and treatment channels on the fluidic biochip and determines if they are significantly different. Toxicant responses of bovine pulmonary artery endothelial cells grown on fluidic biochips are similar to cells on commercially-available open well chips, and these cells can be maintained in the toxicity sensor device for at least nine days using an automated media delivery system. Longer-term cell storage is possible; bovine lung microvessel endothelial cells survive for up to four months on the fluidic biochips and remain responsive to a model toxicant. This is the first demonstration of a portable bench top system capable of both supporting cell health over extended periods of time and obtaining impedance measurements from endothelial cell monolayers after toxicant exposure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Latest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
The Role of Body-on-a-Chip Devices in Drug and Toxicity Studies
Esch, M. B., King, T. L., & Shuler, M. L. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124629 · Cited by 328
Cell-based electrochemical biosensors for water quality assessment
Lagarde, F., & Jaffrezic-Renault, N. (2011) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-4816-7 · Cited by 164
Whole-cell biochips for bio-sensing: integration of live cells and inanimate surfaces
Ben-Yoav, H., Melamed, S., Freeman, A., Shacham-Diamand, Y., & Belkin, S. (2011) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2010.532767 · Cited by 52
Wlodkowic, D., & Karpiński, T. M. (2021) · Sensors · doi:10.3390/s21217028 · Cited by 28
“It has been extensively demonstrated and validated in high-throughput cell cytotoxicity studies in both human and environmental toxicology [137,139,140].”
BackgroundInfluential
Metadata
- Authors
- Curtis, T. M., Widder, M. W., Brennan, L. M., Schwager, S. J., van der Schalie, W. H., Fey, J., & Salazar, N.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 15
- Pages
- 2176
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1963506355
- Cited by
- 107
- References
- 0
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A portable cell-based impedance sensor for toxicity testing of drinking water. https://app.cochat.ai/papers/10.1039/b901314h
- The paper
- Curtis, T. M., Widder, M. W., Brennan, L. M., Schwager, S. J., van der Schalie, W. H., Fey, J., & Salazar, N. (2009). A portable cell-based impedance sensor for toxicity testing of drinking water. Lab on a Chip. https://doi.org/10.1039/b901314h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.