Simultaneous sorting of multiple bacterial targets using integrated Dielectrophoretic–Magnetic Activated Cell Sorter
The DOI matches its Crossref record.
Abstract
The ability to rapidly and accurately sort multiple types of biological targets-such as molecules, viruses, bacteria or mammalian cells-from complex sample mixtures is an essential component for a wide range of diagnostic and therapeutic strategies. However, most current selection methods for cell separation are either limited with regard to throughput, as is the case for Fluorescence Assisted Cell Sorting (FACS), or else only allow binary separation of targets that have been labeled via a single parameter, such as Magnetic Activated Cell Sorting (MACS). We report here the integrated Dielectrophoretic-Magnetic Activated Cell Sorter (iDMACS), an integrated platform that combines two different force fields in a single microfluidic device for highly efficient multi-target separation. We describe the underlying physics and design of the iDMACS device and demonstrate approximately 900-fold enrichment of multiple bacterial target cell types with over 95% purity after a single round of separation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Moon, H.-S., Kwon, K., Kim, S.-I., Han, H., Sohn, J., Lee, S., & Jung, H.-I. (2011) · Lab on a Chip · doi:10.1039/c0lc00345j · Cited by 437
Microfluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
Lab on a chip for continuous-flow magnetic cell separation
Hejazian, M., Li, W., & Nguyen, N.-T. (2015) · Lab on a Chip · doi:10.1039/c4lc01422g · Cited by 347
Lee, W., Kwon, D., Choi, W., Jung, G. Y., Au, A. K., Folch, A., & Jeon, S. (2015) · Scientific Reports · doi:10.1038/srep07717 · Cited by 300
Dalili, A., Samiei, E., & Hoorfar, M. (2019) · The Analyst · doi:10.1039/c8an01061g · Cited by 280
Sorting drops and cells with acoustics: acoustic microfluidic fluorescence-activated cell sorter
Schmid, L., Weitz, D. A., & Franke, T. (2014) · Lab Chip · doi:10.1039/c4lc00588k · Cited by 271
Rare cell capture in microfluidic devices
Pratt, E. D., Huang, C., Hawkins, B. G., Gleghorn, J. P., & Kirby, B. J. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.09.012 · Cited by 194
“More recently, a magnetic separation module was incorporated into the device to capture magnetically tagged cells and separate them from unlabeled non-target cells, which improved the device’s ability to separate multiple cell types (Kim and Soh, 2009).”
BackgroundMethodSingle-Cell Analysis in Biotechnology, Systems Biology, and Biocatalysis
Fritzsch, F. S. O., Dusny, C., Frick, O., & Schmid, A. (2012) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-062011-081056 · Cited by 190
“Kim U, Soh HT. 2009.”
BackgroundInfluentialMicrofluidic Sample Preparation for Single Cell Analysis
Hosic, S., Murthy, S. K., & Koppes, A. N. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04077 · Cited by 166
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
“the device shown in the below row with angled electrodes and ferromagnetic strips (188).”
BackgroundMethodRecent advances in microfluidic methods in cancer liquid biopsy
Iliescu, F. S., Poenar, D. P., Yu, F., Ni, M., Chan, K. H., Cima, I., Taylor, H. K., Cima, I., & Iliescu, C. (2019) · Biomicrofluidics · doi:10.1063/1.5087690 · Cited by 51
Metadata
- Authors
- Kim, U., & Soh, H. T.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2009
- Volume
- 9
- Issue
- 16
- Pages
- 2313
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2092742188
- Cited by
- 100
- References
- 0
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.