The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Colorimetric and fluorescent anion sensors: an overview of recent developments in the use of 1,8-naphthalimide-based chemosensors
Open accessAbstract
This critical review focuses on the development of anion sensors, being either fluorescent and/or colorimetric, based on the use of the 1,8-naphthalimide structure; a highly versatile building unit that absorbs and emits at long wavelengths. The review commences with a short description of the most commonly used design principles employed in chemosensors, followed by a discussion on the photophysical properties of the 4-amino-1,8-naphthalimide structure which has been most commonly employed in both cation and anion sensing to date. This is followed by a review of the current state of the art in naphthalimide-based anion sensing, where systems using ureas, thioureas and amides as hydrogen-bonding receptors, as well as charged receptors have been used for anion sensing in both organic and aqueous solutions, or within various polymeric networks, such as hydrogels. The review concludes with some current and future perspectives including the use of the naphthalimides for sensing small biomolecules, such as amino acids, as well as probes for incorporation and binding to proteins; and for the recognition/sensing of polyanions such as DNA, and their potential use as novel therapeutic and diagnostic agents (95 references).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Spectrophotometric Investigation of the Interaction of Iodine with Aromatic Hydrocarbons
Benesi, H. A., & Hildebrand, J. H. (1949) · Journal of the American Chemical Society · doi:10.1021/ja01176a030 · Cited by 8,004
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Self-citationFluorogenic and Chromogenic Chemosensors and Reagents for Anions
Martínez-Máñez, R., & Sancenón, F. (2003) · Chemical Reviews · doi:10.1021/cr010421e · Cited by 3,076
A new trend in rhodamine-based chemosensors: application of spirolactam ring-opening to sensing ions
Kim, H. N., Lee, M. H., Kim, H. J., Kim, J. S., & Yoon, J. (2008) · Chemical Society Reviews · doi:10.1039/b802497a · Cited by 1,649
Gunnlaugsson, T., Glynn, M., Tocci (née Hussey), G. M., Kruger, P. E., & Pfeffer, F. M. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.08.017 · Cited by 1,257
Self-citationLuminescent sensors and switches in the early 21st century
Callan, J. F., de Silva, A. P., & Magri, D. C. (2005) · Tetrahedron · doi:10.1016/j.tet.2005.05.043 · Cited by 1,123
Sensors for the optical detection ofcyanide ion
Xu, Z., Chen, X., Kim, H. N., & Yoon, J. (2010) · Chem. Soc. Rev. · doi:10.1039/b907368j · Cited by 1,121
Chemical Communication in Water Using Fluorescent Chemosensors
Czarnik, A. W. (1994) · Accounts of Chemical Research · doi:10.1021/ar00046a003 · Cited by 943
Anion receptor chemistry: highlights from 2007
Caltagirone, C., & Gale, P. A. (2009) · Chem. Soc. Rev. · doi:10.1039/b806422a · Cited by 859
Anion receptors based on organic frameworks: highlights from 2005 and 2006
Gale, P. A., García-Garrido, S. E., & Garric, J. (2008) · Chem. Soc. Rev. · doi:10.1039/b715825d · Cited by 782
Teaching Old Indicators New Tricks
Wiskur, S. L., Ait-Haddou, H., Lavigne, J. J., & Anslyn, E. V. (2001) · Accounts of Chemical Research · doi:10.1021/ar9600796 · Cited by 763
Xu, Z., Baek, K.-H., Kim, H. N., Cui, J., Qian, X., Spring, D. R., Shin, I., & Yoon, J. (2010) · Journal of the American Chemical Society · doi:10.1021/ja907334j · Cited by 692
Structural and Molecular Recognition Studies with Acyclic Anion Receptors
Gale, P. A. (2006) · Accounts of Chemical Research · doi:10.1021/ar040237q · Cited by 681
Excited Doublet States of Electrochemically Generated Aromatic Imide and Diimide Radical Anions
Gosztola, D., Niemczyk, M. P., Svec, W., Lukas, A. S., & Wasielewski, M. R. (2000) · The Journal of Physical Chemistry A · doi:10.1021/jp000706f · Cited by 675
Nguyen, B. T., & Anslyn, E. V. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.04.009 · Cited by 668
Recognition and sensing of fluoride anion
Cametti, M., & Rissanen, K. (2009) · Chemical Communications · doi:10.1039/b902069a · Cited by 654
Chemosensors for Pyrophosphate
Kim, S. K., Lee, D. H., Hong, J.-I., & Yoon, J. (2009) · Accounts of Chemical Research · doi:10.1021/ar800003f · Cited by 647
Fluorescent PET (Photoinduced Electron Transfer) sensors as potent analytical tools
de Silva, A. P., Moody, T. S., & Wright, G. D. (2009) · The Analyst · doi:10.1039/b912527m · Cited by 643
Claessens, C. G., González-Rodríguez, D., & Torres, T. (2002) · Chemical Reviews · doi:10.1021/cr0101454 · Cited by 610
Fluoride Ion Recognition by Chelating and Cationic Boranes
Hudnall, T. W., Chiu, C.-W., & Gabbaï, F. P. (2009) · Accounts of Chemical Research · doi:10.1021/ar8001816 · Cited by 519
Ratiometric and Selective Fluorescent Sensor for CuIIBased on Internal Charge Transfer (ICT)
Xu, Z., Xiao, Y., Qian, X., Cui, J., & Cui, D. (2005) · Organic Letters · doi:10.1021/ol0473445 · Cited by 518
Why, on Interaction of Urea-Based Receptors with Fluoride, Beautiful Colors Develop
Esteban-Gómez, D., Fabbrizzi, L., & Licchelli, M. (2005) · The Journal of Organic Chemistry · doi:10.1021/jo050528s · Cited by 507
Supramolecular Analytical Chemistry
Anslyn, E. V. (2007) · The Journal of Organic Chemistry · doi:10.1021/jo0617971 · Cited by 492
Coordination and organometallic compounds as anion receptors and sensors
Steed, J. W. (2009) · Chem. Soc. Rev. · doi:10.1039/b810364j · Cited by 474
Receptors for tetrahedral oxyanions
Katayev, E. A., Ustynyuk, Y. A., & Sessler, J. L. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.04.013 · Cited by 472
Modern reaction-based indicator systems
Cho, D.-G., & Sessler, J. L. (2009) · Chemical Society Reviews · doi:10.1039/b804436h · Cited by 421
Anion recognition using dimetallic coordination complexes
O’Neil, E. J., & Smith, B. D. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.04.006 · Cited by 415
Anion coordination and anion-templated assembly: Highlights from 2002 to 2004
Gale, P. A., & Quesada, R. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.05.020 · Cited by 406
Colorimetric “Naked Eye” Sensing of Anions in Aqueous Solution
Gunnlaugsson, T., Kruger, P. E., Jensen, P., Tierney, J., Ali, H. D. P., & Hussey, G. M. (2005) · The Journal of Organic Chemistry · doi:10.1021/jo0520487 · Cited by 386
Self-citationUrea vs. thiourea in anion recognition
Gómez, D. E., Fabbrizzi, L., Licchelli, M., & Monzani, E. (2005) · Org. Biomol. Chem. · doi:10.1039/b500123d · Cited by 357
A Fluorescent Sensor with High Selectivity and Sensitivity for Potassium in Water
He, H., Mortellaro, M. A., Leiner, M. J. P., Fraatz, R. J., & Tusa, J. K. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0284761 · Cited by 315
Sun, S.-S., & Lees, A. J. (2002) · Coordination Chemistry Reviews · doi:10.1016/s0010-8545(02)00043-7 · Cited by 311
Gunnlaugsson, T., & Leonard, J. P. (2005) · Chemical Communications · doi:10.1039/b418196d · Cited by 298
Self-citationSimple naphthalimide based anion sensors: deprotonation induced colour changes and CO2 fixation
Gunnlaugsson, T., Kruger, P. E., Jensen, P., Pfeffer, F. M., & Hussey, G. M. (2003) · Tetrahedron Letters · doi:10.1016/j.tetlet.2003.09.148 · Cited by 265
Self-citationPalacios, M. A., Nishiyabu, R., Marquez, M., & Anzenbacher, P. (2007) · Journal of the American Chemical Society · doi:10.1021/ja0704784 · Cited by 255
Anion receptors that contain metals as structural units
Amendola, V., & Fabbrizzi, L. (2009) · Chem. Commun. · doi:10.1039/b808264m · Cited by 230
Gunnlaugsson, T., Kruger, P. E., Lee, T. C., Parkesh, R., Pfeffer, F. M., & Hussey, G. M. (2003) · Tetrahedron Letters · doi:10.1016/s0040-4039(03)01699-x · Cited by 225
Self-citationZhu, L., & Anslyn, E. V. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031839s · Cited by 216
Gunnlaugsson, T., Davis, A. P., Hussey, G. M., Tierney, J., & Glynn, M. (2004) · Organic & Biomolecular Chemistry · doi:10.1039/b404706k · Cited by 210
Self-citationRational Design of a Fluorescence‐Turn‐On Sensor Array for Phosphates in Blood Serum
Zyryanov, G. V., Palacios, M. A., & Anzenbacher, P. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200702611 · Cited by 206
Influence of dimensionality and charge on anion binding in amide-based macrocyclic receptors
Kang, S. O., Hossain, M. A., & Bowman-James, K. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.06.006 · Cited by 205
Massue, J., Quinn, S. J., & Gunnlaugsson, T. (2008) · Journal of the American Chemical Society · doi:10.1021/ja800361e · Cited by 202
Self-citationColorimetric Recognition of Anions Using Preorganized Tetra-Amidourea Derived Calix[4]arene Sensors
Quinlan, E., Matthews, S. E., & Gunnlaugsson, T. (2007) · The Journal of Organic Chemistry · doi:10.1021/jo070439a · Cited by 201
Self-citationGunnlaugsson, T., Davis, A. P., O'Brien, J. E., & Glynn, M. (2005) · Organic & Biomolecular Chemistry · doi:10.1039/b409018g · Cited by 198
Self-citationDendrimers and gold nanoparticles as exo-receptors sensing biologically important anions
Astruc, D., Daniel, M.-C., & Ruiz, J. (2004) · Chemical Communications · doi:10.1039/b410399h · Cited by 198
Davis, J. T., Gale, P. A., Okunola, O. A., Prados, P., Iglesias-Sánchez, J. C., Torroba, T., & Quesada, R. (2009) · Nature Chemistry · doi:10.1038/nchem.178 · Cited by 198
Camiolo, S., Gale, P. A., Hursthouse, M. B., & Light, M. E. (2003) · Organic & Biomolecular Chemistry · doi:10.1039/b210848h · Cited by 189
Chen, Z., Liang, X., Zhang, H., Xie, H., Liu, J., Xu, Y., Zhu, W., Wang, Y., Wang, X., Tan, S., et al. (2010) · Journal of Medicinal Chemistry · doi:10.1021/jm100025u · Cited by 171
A Synthetically Simple, Click-Generated Cyclam-Based Zinc(II) Sensor
Tamanini, E., Katewa, A., Sedger, L. M., Todd, M. H., & Watkinson, M. (2009) · Inorganic Chemistry · doi:10.1021/ic8017634 · Cited by 161
Anion Recognition Using Preorganized Thiourea Functionalized [3]Polynorbornane Receptors
Pfeffer, F. M., Gunnlaugsson, T., Jensen, P. R., & Kruger, P. E. (2005) · Organic Letters · doi:10.1021/ol051497q · Cited by 148
Self-citationAnzenbacher, P., Nishiyabu, R., & Palacios, M. A. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.09.001 · Cited by 143
Selective fluorescent PET sensing of fluoride (F−) using naphthalimide–thiourea and –urea conjugates
Duke, R. M., & Gunnlaugsson, T. (2007) · Tetrahedron Letters · doi:10.1016/j.tetlet.2007.09.026 · Cited by 132
Self-citationGunnlaugsson, T., Lee, T. C., & Parkesh, R. (2003) · Organic & Biomolecular Chemistry · doi:10.1039/b309569j · Cited by 130
Self-citationA modular approach to organic, coordination complex and polymer based podand hosts for anions
Filby, M. H., & Steed, J. W. (2006) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2006.06.004 · Cited by 128
Veale, E. B., Tocci, G. M., Pfeffer, F. M., Kruger, P. E., & Gunnlaugsson, T. (2009) · Organic & Biomolecular Chemistry · doi:10.1039/b907037k · Cited by 128
Self-citationOctafluorocalix[4]pyrrole: A Chloride/Bicarbonate Antiport Agent
Gale, P. A., Tong, C. C., Haynes, C. J. E., Adeosun, O., Gross, D. E., Karnas, E., Sedenberg, E., Quesada, R., & Sessler, J. L. (2010) · Journal of the American Chemical Society · doi:10.1021/ja9092693 · Cited by 124
Visible and near-infrared sensing of fluoride by indole conjugated urea/thiourea ligands
Bose, P., & Ghosh, P. (2010) · Chemical Communications · doi:10.1039/b919128c · Cited by 119
Cyclam-Based “Clickates”: Homogeneous and Heterogeneous Fluorescent Sensors for Zn(II)
Tamanini, E., Flavin, K., Motevalli, M., Piperno, S., Gheber, L. A., Todd, M. H., & Watkinson, M. (2010) · Inorganic Chemistry · doi:10.1021/ic901939x · Cited by 114
Fluoride Ion-Triggered Dual Fluorescence Switch Based on Naphthalimides Winged Zinc Porphyrin
Li, Y., Cao, L., & Tian, H. (2006) · The Journal of Organic Chemistry · doi:10.1021/jo061161+ · Cited by 114
Braña, M. F., Cacho, M., García, M. A., de Pascual‐Teresa, B., Ramos, A., Domínguez, M. T., Pozuelo, J. M., Abradelo, C., Rey-Stolle, F., Yuste, M., et al. (2004) · Journal of Medicinal Chemistry · doi:10.1021/jm0308850 · Cited by 112
Quinlan, E., Matthews, S. E., & Gunnlaugsson, T. (2006) · Tetrahedron Letters · doi:10.1016/j.tetlet.2006.10.112 · Cited by 108
Self-citationDuke, R. M., O’Brien, J. E., McCabe, T., & Gunnlaugsson, T. (2008) · Organic & Biomolecular Chemistry · doi:10.1039/b807579d · Cited by 107
Self-citationPfeffer, F. M., Buschgens, A. M., Barnett, N. W., Gunnlaugsson, T., & Kruger, P. E. (2005) · Tetrahedron Letters · doi:10.1016/j.tetlet.2005.07.067 · Cited by 107
Self-citationFluorescent PET(Photoinduced Electron Transfer) reagents for thiols
de Silva, A. P., Gunaratne, H. Q. N., & Gunnlaugsson, T. (1998) · Tetrahedron Letters · doi:10.1016/s0040-4039(98)00909-5 · Cited by 94
Self-citationMultivalued Logic with a Tristable Fluorescent Switch
Ferreira, R., Remón, P., & Pischel, U. (2009) · The Journal of Physical Chemistry C · doi:10.1021/jp809527d · Cited by 89
A new twist in anion binding: metallo-helicate hosts for anionic guests
Goetz, S., & Kruger, P. E. (2006) · Dalton Transactions · doi:10.1039/b514580e · Cited by 87
Self-citationLowe, A. J., Dyson, G., & Pfeffer, F. M. (2007) · Organic & Biomolecular Chemistry · doi:10.1039/b703626b · Cited by 60
Self-citationQu, Y., Hua, J., Jiang, Y., & Tian, H. (2009) · Journal of Polymer Science Part A Polymer Chemistry · doi:10.1002/pola.23257 · Cited by 60
Roy, S., Saha, S., Majumdar, R., Dighe, R. R., & Chakravarty, A. R. (2009) · Inorganic Chemistry · doi:10.1021/ic9015355 · Cited by 59
Judd, L. W., & Davis, A. P. (2010) · Chemical Communications · doi:10.1039/b927005a · Cited by 59
Polymer Fluoride Sensors Synthesized by RAFT Polymerization
Zhao, P., Jiang, J., Leng, B., & Tian, H. (2009) · Macromolecular Rapid Communications · doi:10.1002/marc.200900318 · Cited by 54
Colorimetric naked‐eye recognizable anion sensors synthesized via RAFT polymerization
Jiang, J., Xiao, X., Zhao, P., & Tian, H. (2010) · Journal of Polymer Science Part A Polymer Chemistry · doi:10.1002/pola.23922 · Cited by 50
Factors Influencing Anion Binding Stoichiometry: The Subtle Influence of Electronic Effects
Lowe, A. J., Dyson, G., & Pfeffer, F. M. (2008) · European Journal of Organic Chemistry · doi:10.1002/ejoc.200701015 · Cited by 40
Self-citationParkesh, R., Lee, T. C., & Gunnlaugsson, T. (2009) · Tetrahedron Letters · doi:10.1016/j.tetlet.2009.04.115 · Cited by 39
Self-citation1,8-Naphthalimide hydroperoxides as novel intercalating DNA cleavers
Tao, Z., Qian, X. H., & Wei, D. (1996) · Dyes and Pigments · doi:10.1016/0143-7208(95)00105-0 · Cited by 17
Cited by
Fluorescent Chemosensors Based on Spiroring-Opening of Xanthenes and Related Derivatives
Chen, X., Pradhan, T., Wang, F., Kim, J. S., & Yoon, J. (2012) · Chemical Reviews · doi:10.1021/cr200201z · Cited by 1,984
Yuan, L., Lin, W., Zheng, K., He, L., & Huang, W. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35313j · Cited by 1,822
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
Small molecule-based ratiometric fluorescence probes for cations, anions, and biomolecules
Lee, M. H., Kim, J. S., & Sessler, J. L. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00280f · Cited by 1,642
Applications of Supramolecular Anion Recognition
Busschaert, N., Caltagirone, C., Van Rossom, W., & Gale, P. A. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00099 · Cited by 1,249
Metadata
- Authors
- Duke, R. M., Veale, E. B., Pfeffer, F. M., Kruger, P. E., & Gunnlaugsson, T.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 39
- Issue
- 10
- Pages
- 3936
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2053142417
- Cited by
- 1,220
- References
- 75
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.