Microfluidic stochastic confinement enhances analysis of rare cells by isolating cells and creating high density environments for control of diffusible signals
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Rare cells can be difficult to analyze because they either occur in low numbers or coexist with a more abundant cell type, yet their detection is crucial for diagnosing disease and maintaining human health. In this tutorial review, we introduce the concept of microfluidic stochastic confinement for use in detection and analysis of rare cells. Stochastic confinement provides two advantages: (1) it separates rare single cells from the bulk mixture and (2) it allows signals to locally accumulate to a higher concentration around a single cell than in the bulk mixture. Microfluidics is an attractive method for implementing stochastic confinement because it provides simple handling of small volumes. We present technologies for microfluidic stochastic confinement that utilize both wells and droplets for the detection and analysis of single cells. We address how these microfluidic technologies have been used to observe new behavior, increase speed of detection, and enhance cultivation of rare cells. We discuss potential applications of microfluidic stochastic confinement to fields such as human diagnostics and environmental testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zengler, K., Toledo, G., Rappé, M., Elkins, J., Mathur, E. J., Short, J. M., & Keller, M. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.252630999 · Cited by 796
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Self-citation
Cited by
Physicochemical regulation of biofilm formation
Renner, L. D., & Weibel, D. B. (2011) · MRS Bulletin · doi:10.1557/mrs.2011.65 · Cited by 616
Wilpiszeski, R. L., Aufrecht, J. A., Retterer, S. T., Sullivan, M. B., Graham, D. E., Pierce, E. M., Zablocki, O. D., Palumbo, A. V., & Elias, D. A. (2019) · Applied and Environmental Microbiology · doi:10.1128/aem.00324-19 · Cited by 441
Droplet microfluidics for microbiology: techniques, applications and challenges
Kaminski, T. S., Scheler, O., & Garstecki, P. (2016) · Lab on a Chip · doi:10.1039/c6lc00367b · Cited by 424
Microfluidics for single cell analysis
Yin, H., & Marshall, D. (2012) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2011.11.002 · Cited by 394
Rare cell isolation and analysis in microfluidics
Chen, Y., Li, P., Huang, P.-H., Xie, Y., Mai, J. D., Wang, L., Nguyen, N.-T., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc90136j · Cited by 307
The role of physiological heterogeneity in microbial population behavior
Lidstrom, M. E., & Konopka, M. C. (2010) · Nature Chemical Biology · doi:10.1038/nchembio.436 · Cited by 296
Shen, F., Du, W., Kreutz, J. E., Fok, A., & Ismagilov, R. F. (2010) · Lab on a Chip · doi:10.1039/c004521g · Cited by 295
Self-citationLagus, T. P., & Edd, J. F. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/11/114005 · Cited by 213
Diversity of Phage-Displayed Libraries of Peptides during Panning and Amplification
Derda, R., Tang, S. K. Y., Li, S. C., Ng, S., Matochko, W., & Jafari, M. R. (2011) · Molecules · doi:10.3390/molecules16021776 · Cited by 204
High-throughput combinatorial cell co-culture using microfluidics
Tumarkin, E., Tzadu, L., Csaszar, E., Seo, M., Zhang, H., Lee, A., Peerani, R., Purpura, K., Zandstra, P. W., & Kumacheva, E. (2011) · Integrative Biology · doi:10.1039/c1ib00002k · Cited by 192
Yang, R., Paparini, A., Monis, P., & Ryan, U. (2014) · International Journal for Parasitology · doi:10.1016/j.ijpara.2014.08.004 · Cited by 190
Ma, L., Kim, J., Hatzenpichler, R., Karymov, M. A., Hubert, N., Hanan, I. M., Chang, E. B., & Ismagilov, R. F. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1404753111 · Cited by 158
“…microdroplets (14), miniaturized Petri dishes (15), and microfluidics (16 – 19), have become increasingly promising as a basis for targeted microbial cultivation and isolation platforms, as they can limit the consumption of precious samples and also control the microenvironment around cells (20).”
BackgroundSelf-citationKreutz, J. E., Munson, T., Huynh, T., Shen, F., Du, W., & Ismagilov, R. F. (2011) · Analytical Chemistry · doi:10.1021/ac201658s · Cited by 148
Self-citationNanotechnology: emerging tools for biology and medicine
Wong, I. Y., Bhatia, S. N., & Toner, M. (2013) · Genes & Development · doi:10.1101/gad.226837.113 · Cited by 132
Metadata
- Authors
- Vincent, M. E., Liu, W., Haney, E. B., & Ismagilov, R. F.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 39
- Issue
- 3
- Pages
- 974
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2109398583
- Cited by
- 102
- References
- 2
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.