CoChat

Resonant Mie Scattering (RMieS) correction of infrared spectra from highly scattering biological samples

Open access
Bassan, Paul, Kohler, Achim, Martens, Harald, Lee, Joe, Byrne, Hugh J., Dumas, Paul, Gazi, Ehsan, Brown, Michael, Clarke, Noel, Gardner, Peter · 2010 · The Analyst

The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.

Abstract

Infrared spectra of single biological cells often exhibit the 'dispersion artefact' observed as a sharp decrease in intensity on the high wavenumber side of absorption bands, in particular the Amide I band at approximately 1655 cm(-1), causing a downward shift of the true peak position. The presence of this effect makes any biochemical interpretation of the spectra unreliable. Recent theory has shed light on the origins of the 'dispersion artefact' which has been attributed to resonant Mie scattering (RMieS). In this paper a preliminary algorithm for correcting RMieS is presented and evaluated using simulated data. Results show that the 'dispersion artefact' appears to be removed; however, the correction is not perfect. An iterative approach was subsequently implemented whereby the reference spectrum is improved after each iteration, resulting in a more accurate correction. Consequently the corrected spectra become increasingly more representative of the pure absorbance spectra. Using this correction method reliable peak positions can be obtained.

Overview

Integrity signals

Registry

Crossref · 10.1039/b921056c

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 32 references

Research works printed but not linked: 1

  1. Kramer, 1927, Atti Congr. Intern. Fisica Como, 2, 545

Cited by

Items 101–200 of 384

Metadata

Authors
Bassan, P., Kohler, A., Martens, H., Lee, J., Byrne, H. J., Dumas, P., Gazi, E., Brown, M., Clarke, N., & Gardner, P.
Affiliations
  • University of Manchester (GB)
  • Nofima (NO)
  • Dublin Institute of Technology (IE)
  • Synchrotron SOLEIL (FR)
  • Manchester Academic Health Science Centre (GB)
Corresponding author
Gardner, Peter
Venue
The Analyst
Published
2010
Volume
135
Issue
2
Pages
268-277
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W2167273463
Cited by
375
References
32
Citations by year
2026: 11 · 2025: 13 · 2024: 12 · 2023: 20 · 2022: 20 · 2021: 21 · 2020: 30 · 2019: 22 · 2018: 19 · 2017: 14 · 2016: 23 · 2015: 34 · 2014: 28 · 2013: 39 · 2012: 27
FWCI
13.50
Type
journal article
Language
en
Licence
other-oa
Locations
  • The Analyst (publishedVersion)
  • PubMed (publishedVersion)
  • Research Explorer (The University of Manchester) (submittedVersion, other-oa)
Funders
Engineering and Physical Sciences Research Council
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Spectroscopy and Quantum Chemical Studies
Keywords
infrared spectra, biological cells, amide I band, peak shift
MeSH terms
Algorithms, Computer Simulation, Humans, Male, Prostatic Neoplasms, Reference Standards, Tumor Cells, Cultured, Spectroscopy, Fourier Transform Infrared

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.