Resonant Mie Scattering (RMieS) correction of infrared spectra from highly scattering biological samples
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Infrared spectra of single biological cells often exhibit the 'dispersion artefact' observed as a sharp decrease in intensity on the high wavenumber side of absorption bands, in particular the Amide I band at approximately 1655 cm(-1), causing a downward shift of the true peak position. The presence of this effect makes any biochemical interpretation of the spectra unreliable. Recent theory has shed light on the origins of the 'dispersion artefact' which has been attributed to resonant Mie scattering (RMieS). In this paper a preliminary algorithm for correcting RMieS is presented and evaluated using simulated data. Results show that the 'dispersion artefact' appears to be removed; however, the correction is not perfect. An iterative approach was subsequently implemented whereby the reference spectrum is improved after each iteration, resulting in a more accurate correction. Consequently the corrected spectra become increasingly more representative of the pure absorbance spectra. Using this correction method reliable peak positions can be obtained.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Beiträge zur Optik trüber Medien, speziell kolloidaler Metallösungen
Mie, G. (1908) · Annalen der Physik · doi:10.1002/andp.19083300302 · Cited by 11,537
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
On the Theory of Dispersion of X-Rays
de L. Kronig, R. (1926) · Journal of the Optical Society of America · doi:10.1364/josa.12.000547 · Cited by 1,987
Basement membrane complexes with biological activity
Kleinman, H. K., McGarvey, M. L., Hassell, J. R., Star, V. L., Cannon, F. B., Laurie, G. W., & Martin, G. R. (1986) · Biochemistry · doi:10.1021/bi00350a005 · Cited by 1,502
Hartmann, M. (1984) · Acta Polymerica · doi:10.1002/actp.1984.010350426 · Cited by 1,071
Martens, H., Nielsen, J. P., & Engelsen, S. B. (2003) · Analytical Chemistry · doi:10.1021/ac020194w · Cited by 507
Self-citationBiological applications of infrared spectroscopy
Stuart, B. H., & Ando, D. (1997) · Medical Entomology and Zoology · Cited by 339
Bassan, P., Byrne, H. J., Bonnier, F., Lee, J., Dumas, P., & Gardner, P. (2009) · The Analyst · doi:10.1039/b904808a · Cited by 316
Self-citationHighly resolved chemical imaging of living cells by using synchrotron infrared microspectrometry
Jamin, N., Dumas, P., Moncuit, J., Fridman, W.-H., Teillaud, J.-L., Carr, G. L., & Williams, G. P. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.9.4837 · Cited by 251
Self-citationMohlenhoff, B., Romeo, M., Diem, M., & Wood, B. R. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.057950 · Cited by 236
Research works printed but not linked: 1
- Kramer, 1927, Atti Congr. Intern. Fisica Como, 2, 545
Cited by
Items 201–300 of 384
Meyvisch, P., Gurdebeke, P. R., Vrielinck, H., Mertens, K. N., Versteegh, G. J. M., & Louwye, S. (2021) · Applied Spectroscopy · doi:10.1177/00037028211041172 · Cited by 19
Balbekova, A., Lohninger, H., van Tilborg, G. A. F., Dijkhuizen, R. M., Bonta, M., Limbeck, A., Lendl, B., Al‐Saad, K. A., Ali, M. H. M., Čelikić, M., et al. (2017) · Applied Spectroscopy · doi:10.1177/0003702817734618 · Cited by 18
Keogan, A., Nguyen, T. N. Q., Bouzy, P., Stone, N., Jirström, K., Rahman, A., Gallagher, W. M., & Meade, A. D. (2025) · npj Precision Oncology · doi:10.1038/s41698-024-00772-x · Cited by 24
Fourier-transform mid-infrared FPA imaging of a complex multicellular nematode
Hobro, A. J., & Lendl, B. (2011) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2011.07.007 · Cited by 17
Estimating and correcting interference fringes in infrared spectra in infrared hyperspectral imaging
Azarfar, G., Aboualizadeh, E., Walter, N. M., Ratti, S., Olivieri, C., Norici, A., Nasse, M. J., Köhler, A., Giordano, M., & Hirschmugl, C. J. (2018) · The Analyst · doi:10.1039/c8an00093j · Cited by 17
Sandt, C., & Borondics, F. (2021) · The Analyst · doi:10.1039/d1an00695a · Cited by 17
Ami, D., Segni, M. D., Forcella, M. E., Meraviglia, V., Baccarin, M., Doglia, S. M., & Terzoli, G. L. (2014) · European Journal of Histochemistry · doi:10.4081/ejh.2014.2330 · Cited by 17
Discrimination of melanoma cell lines with Fourier Transform Infrared (FTIR) spectroscopy
Shakya, B. R., Teppo, H., & Rieppo, L. (2021) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2021.119665 · Cited by 17
Chemometrics in Biospectroscopy
Köhler, A., Afseth, N. K., & Martens, H. A. (2001) · Wiley eBooks · doi:10.1002/0470027320.s8937 · Cited by 17
Self-citationHughes, C. S., Brown, M. D., Clarke, N. W., Flower, K. R., & Gardner, P. (2012) · The Analyst · doi:10.1039/c2an35632e · Cited by 16
Self-citationDiscrimination of smokers and nonsmokers based on the analysis of fingermarks for forensic purposes
Amin, M. O., Al‐Hetlani, E., & Lednev, I. K. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.108466 · Cited by 16
Jochemsen, A., Alfredsen, G., Martens, H. A., & Burud, I. (2024) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2024.105187 · Cited by 17
Self-citationIncreased optical pathlength through aqueous media for the infrared microanalysis of live cells
Doherty, J., Zhang, Z., Wehbe, K., Cinque, G., Gardner, P., & Denbigh, J. L. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1188-2 · Cited by 16
Self-citationAli, M. H. M., Rakib, F., Nischwitz, V., Ullah, E., Mall, R., Shraim, A. M., Ahmad, M. I., Ghouri, Z. K., McNaughton, D., Küppers, S., et al. (2018) · Applied Sciences · doi:10.3390/app8122436 · Cited by 16
Liu, S., Hall, D. J., McCarthy, S. M., Jacobs, J. J., Urban, R. M., & Pourzal, R. (2019) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34408 · Cited by 16
Rasskazov, I. L., Singh, R., Carney, P. S., & Bhargava, R. (2019) · Applied Spectroscopy · doi:10.1177/0003702819844528 · Cited by 17
Goertzen, N., Pappesch, R., Fassunke, J., Brüning, T., Ko, Y., Schmidt, J., Großerueschkamp, F., Buettner, R., & Gerwert, K. B. (2021) · American Journal Of Pathology · doi:10.1016/j.ajpath.2021.04.013 · Cited by 16
Diem, M., Miljković, M. D., Bird, B., Mazur, A. I., Schubert, J., Townsend, D., Laver, N., Almond, M., & Old, O. J. (2015) · The Analyst · doi:10.1039/c5an01751c · Cited by 16
Tan, S.-T., Balasubramanian, R. K., Das, P., Obbard, J. P., & Chew, W. (2013) · Bioresource Technology · doi:10.1016/j.biortech.2013.01.060 · Cited by 15
Dillon, C. T. (2011) · Australian Journal of Chemistry · doi:10.1071/ch11287 · Cited by 15
SR-FTIR Coupled with Principal Component Analysis Shows Evidence for the Cellular Bystander Effect
Lipiec, E. W., Bambery, K. R., Lekki, J., Tobin, M. J., Vogel, C., Whelan, D. R., Wood, B. R., & Kwiatek, W. M. (2015) · Radiation Research · doi:10.1667/rr13798.1 · Cited by 15
Song, C. L., & Kazarian, S. G. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01002 · Cited by 15
Croxford, A. M., Rowley, M. J., McNaughton, D., Kutty Selva, N., Holmdahl, R., & Tobin, M. J. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3585680 · Cited by 14
Guo, Y., Chen, T., Wang, S., Zhou, X., Zhang, H., Li, D., Mu, N., Tang, M., Hu, M., Tang, D., et al. (2020) · ACS Omega · doi:10.1021/acsomega.0c03285 · Cited by 15
Using FTIR Imaging to Investigate Silk Fibroin-Based Materials
Zhong, J., Zhou, X., Ye, C., Yu, W., & Tang, Y. (2021) · Methods in molecular biology · doi:10.1007/978-1-0716-1574-4_18 · Cited by 14
Microimaging FT-IR of head and neck tumors. V. Odontogenic cystic lesions
Tosi, G., Balercia, P., Conti, C., Ferraris, P. C., Giorgini, E., Muzio, L. L., Sabbatini, S., Stramazzotti, D., & Rubini, C. (2011) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2011.06.006 · Cited by 14
Ricciardi, V., Portaccio, M., Perna, G., Lasalvia, M., Capozzi, V., Cammarata, F. P., Pisciotta, P., Petringa, G., Delfino, I., Manti, L., et al. (2021) · Applied Sciences · doi:10.3390/app11020540 · Cited by 14
Time-Dependent Debye–Mie Series Solutions for Electromagnetic Scattering
Li, J., & Shanker, B. (2015) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2015.2439294 · Cited by 14
Effect of pre-analytical variables on Raman and FTIR spectral content of lymphocytes
Monaghan, J. F., Cullen, D., Wynne, C., Lyng, F. M., & Meade, A. D. (2023) · The Analyst · doi:10.1039/d3an00686g · Cited by 14
Muñoz‐Juan, A., Assié, A., Esteve‐Codina, A., Gut, M., Benseny‐Cases, N., Samuel, B. S., Dalfó, E., & Laromaine, A. (2024) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2024.121815 · Cited by 16
Khambatta, K., Hollings, A. L., Sauzier, G., Sanglard, L. V. P., Klein, A. R., Tobin, M. J., Vongsvivut, J. P., Gibberd, M., Payne, A. D., Naim, F., et al. (2021) · Advanced Science · doi:10.1002/advs.202101902 · Cited by 13
Bi, Y., Tang, L., Shan, P., Xie, Q., Hu, Y. X., Peng, S., Tan, J., & Li, C. (2014) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2014.03.080 · Cited by 13
Automated cytological detection of Barrett’s neoplasia with infrared spectroscopy
Old, O. J., Lloyd, G. R., Isabelle, M., Almond, M., Kendall, C. A., Baxter, K., Shepherd, N. A., Shore, A. C., Stone, N., & Barr, H. (2017) · Journal of Gastroenterology · doi:10.1007/s00535-017-1344-z · Cited by 13
Chrabąszcz, K., Kaminska, K. H., Song, C. L., Morikawa, J., Kujdowicz, M., Michalczyk, E., Smęda, M., Stojak, M., Jasztal, A., Kazarian, S. G., et al. (2021) · Cancers · doi:10.3390/cancers13020162 · Cited by 13
Shakya, B. R., Teppo, H., & Rieppo, L. (2022) · The Analyst · doi:10.1039/d1an01999f · Cited by 13
A comparison of mid-infrared spectral regions on accuracy of tissue classification
Mittal, S., & Bhargava, R. (2019) · The Analyst · doi:10.1039/c8an01782d · Cited by 14
Monaghan, J. F., Byrne, H. J., Lyng, F. M., & Meade, A. D. (2024) · Radiation · doi:10.3390/radiation4030022 · Cited by 12
Self-citationRosas, S., Biswas, S. K., Adi, W., Kuruoğlu, F., Beisenova, A., Patankar, M. S., & Yesilköy, F. (2025) · Advanced Materials · doi:10.1002/adma.202504355 · Cited by 16
An evaluation of the application of the aperture infrared SNOM technique to biomedical imaging
Ingham, J., Pilling, M. J., Craig, T., Siggel-King, M. R. F., Smith, C. I., Gardner, P., Varró, A., Pritchard, D. M., Barrett, S. D., Martin, D. S., et al. (2017) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aaa0de · Cited by 12
Self-citationA novel FTIR analysis method for rapid high-confidence discrimination of esophageal cancer
Ingham, J., Pilling, M. J., Martin, D. S., Smith, C. I., Ellis, B. G., Whitley, C. A., Siggel-King, M. R. F., Harrison, P. D., Craig, T., Varró, A., et al. (2019) · Infrared Physics & Technology · doi:10.1016/j.infrared.2019.103007 · Cited by 12
Self-citationAugustyniak, K., Leśniak, M., Golan, M. P., Latka, H., Wojtan, K., Zdanowski, R., Kubiak, J. Z., & Małek, K. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms252212274 · Cited by 11
Solheim, J. H., Borondics, F., Zimmermann, B., Sandt, C., Muthreich, F., & Köhler, A. (2021) · Journal of Biophotonics · doi:10.1002/jbio.202100148 · Cited by 13
Sahu, R. K., & Mordechai, S. (2010) · Future Oncology · doi:10.2217/fon.10.120 · Cited by 11
Mignolet, A., & Goormaghtigh, E. (2014) · The Analyst · doi:10.1039/c4an01834f · Cited by 11
Schofield, A. J., Blümel, R., Köhler, A., Lukács, R., & Hirschmugl, C. J. (2019) · The Journal of Chemical Physics · doi:10.1063/1.5085207 · Cited by 12
Wróbel, T. P., Kozioł, P., Raczkowska, M. K., Liberda, D., Paluszkiewicz, C., & Kwiatek, W. M. (2019) · Scientific Data · doi:10.1038/s41597-019-0260-x · Cited by 11
Lipid mediated formation of antiparallel aggregates in cerebral amyloid angiopathy
de Oliveira, A. P., Baghel, D., Holcombe, B., Chase, W., Ward, T., Wang, S. J., & Ghosh, A. (2025) · Acta Neuropathologica · doi:10.1007/s00401-025-02911-5 · Cited by 10
Zhong, J., Yu, W., Tang, Y., & Zhou, X. (2022) · ACS Omega · doi:10.1021/acsomega.2c06622 · Cited by 10
Balla, M. M. S., Ningthoujam, R. S., Kumar, M., Bandekar, J. R., & Pandey, B. N. (2016) · Journal of Cancer Research and Therapeutics · doi:10.4103/0973-1482.171365 · Cited by 11
Szafraniec, E., Wiercigroch, E., Czamara, K., Majzner, K., Staniszewska‐Slezak, E., Marzec, K. M., Małek, K., Kaczor, A., & Barańśka, M. (2018) · The Analyst · doi:10.1039/c8an00239h · Cited by 10
Zhou, X., Zhong, J., Yu, W., & Tang, Y. (2022) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2022.121773 · Cited by 10
Khalifa, O., Mroué, K. H., Mall, R., Ullah, E., Al-Akl, N. S., & Arredouani, A. (2022) · Biomedicines · doi:10.3390/biomedicines10102652 · Cited by 10
Laginha, R. C., Martins, C. B., Brandão, A. L., Marques, J., Marques, M. P. M., de Carvalho, L. A. E. B., Santos, I. P., & de Carvalho, A. L. M. B. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms24031888 · Cited by 10
Mavrogenis, A. F., Kyriakidou, M., Kyriazis, S., & Anastassopoulou, J. D. (2016) · Expert Review of Quality of Life in Cancer Care · doi:10.1080/23809000.2016.1254553 · Cited by 10
Zadka, Ł., Chrabąszcz, K., Buzalewicz, I., Wiercigroch, E., Glatzel-Plucinska, N. M., Szleszkowski, Ł., Gomułkiewicz, A., Piotrowska, A., Kurnol, K., Dzięgiel, P., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-90761-y · Cited by 10
Guilbert, M., Eklouh‐Molinier, C., Wehbe, K., Sulé‐Suso, J., Yang, Y., Cinque, G., Jeannesson, P., & Sockalingum, G. D. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.11.111612 · Cited by 10
Yang, C., Niedieker, D., Großerueschkamp, F., Horn, M., Tannapfel, A., Kallenbach‐Thieltges, A., Gerwert, K. B., & Mosig, A. (2015) · BMC Bioinformatics · doi:10.1186/s12859-015-0804-9 · Cited by 10
Sheng, X., Xu, J., Sun, Y., Zhao, J., Cao, Y. B., Jiang, L., Wu, T., Lü, H., Duan, C., & Hu, J. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341434 · Cited by 9
Wilkins, J. M., Gakh, O., Guo, Y. X., Popescu, B. F. G., Staff, N. P., & Lucchinetti, C. F. (2023) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2023.1223912 · Cited by 9
Augustyniak, K., Chrabąszcz, K., Smęda, M., Stojak, M., Marzec, K. M., & Małek, K. (2021) · Applied Spectroscopy · doi:10.1177/00037028211025540 · Cited by 9
Perez-Berna, A. J., Benseny‐Cases, N., Gómez-Rodríguez, M. J., Valcárcel, R., Carrascosa, J. L., Gastaminza, P., & Pereiro, E. (2021) · Acta Crystallographica Section D Structural Biology · doi:10.1107/s2059798321009955 · Cited by 9
Scattering in Biomedical Infrared Spectroscopy
Bassan, P., & Gardner, P. (2010) · Royal Society of Chemistry eBooks · doi:10.1039/9781849731997-00260 · Cited by 9
Self-citationTrukhan, S. V., Tafintseva, V., Tøndel, K., Großerueschkamp, F., Mosig, A., Kovalev, V. A., Gerwert, K. B., & Köhler, A. (2020) · Journal of Biophotonics · doi:10.1002/jbio.201960223 · Cited by 9
Raulf, A., Butke, J., Menzen, L., Küpper, C., Großerueschkamp, F., Gerwert, K. B., & Mosig, A. (2020) · Journal of Biophotonics · doi:10.1002/jbio.202000385 · Cited by 9
Tang, Y., Deng, R., Li, J., Liang, Y., Xiong, L., Liu, Y., Zhang, R., & Hua, Z. (2021) · Remote Sensing · doi:10.3390/rs13132463 · Cited by 9
Bakir, G., Dahms, T. E. S., Martin‐Yken, H., Bechtel, H. A., & Gough, K. M. (2024) · Applied Spectroscopy · doi:10.1177/00037028231213658 · Cited by 8
Infrared microspectroscopic determination of collagen cross-links in articular cartilage
Rieppo, L., Kokkonen, H. T., Kulmala, K. A. M., Kovanen, V., Lammi, M. J., Töyräs, J., & Saarakkala, S. S. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.3.035007 · Cited by 8
Smęda, M., Jasztal, A., Maleki, E. H., Bar, A., Sternak, M., Kwiatkowski, G., Suraj, J., Proniewski, B., Kieronska‐Rudek, A., Wojnar‐Lason, K., et al. (2022) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2022.1050112 · Cited by 8
Pięta, E., Chrabąszcz, K., Pogoda, K., Suchy, K., Paluszkiewicz, C., & Kwiatek, W. M. (2022) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2022.166615 · Cited by 8
Beeck, M. O. D., Troein, C., Peterson, C., Tunlid, A., & Persson, P. (2024) · Applied and Environmental Microbiology · doi:10.1128/aem.01489-23 · Cited by 8
Principles of Vibrational Spectroscopic Methods and their Application to Bioanalysis
Moore, D. S., Jepsen, P. U., & Volka, K. (2014) · Wiley eBooks · doi:10.1002/9783527654703.ch27 · Cited by 11
Chonanant, C., Bambery, K. R., Jearanaikoon, N., Chio‐Srichan, S., Limpaiboon, T., Tobin, M. J., Heraud, P., & Jearanaikoon, P. (2014) · Talanta · doi:10.1016/j.talanta.2014.05.037 · Cited by 8
Multivariate classification of fourier transform infrared hyperspectral images of skin cancer cells
Peñaranda, F., Naranjo, V., Kastl, L., Kemper, B., Lloyd, G. R., Nallala, J., Stone, N., & Schnekenburger, J. (2016) · European Signal Processing Conference (EUSIPCO) · doi:10.1109/eusipco.2016.7760464 · Cited by 8
Kowalska, J. K., Gajda, M., Kwiatek, W. M., Franczyk‐Żarów, M., Kostogrys, R. B., Chłopicki, S., Sandt, C., & Dumas, P. (2012) · Acta Physica Polonica A · doi:10.12693/aphyspola.121.555 · Cited by 8
Self-citationInfrared and Raman Spectroscopic Mapping and Imaging of Plant Materials
Schulz, H., Krähmer, A., Naumann, A., & Gudi, G. (2014) · Wiley eBooks · doi:10.1002/9783527678136.ch6 · Cited by 15
Augustyniak, K., Pragnąca, A., Leśniak, M., Hałasa, M., Borkowska, A., Pięta, E., Kwiatek, W. M., Kiéda, C., Zdanowski, R., & Małek, K. (2023) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-023-04986-3 · Cited by 7
Müller, D., Schuhmacher, D., Schörner, S., Großerueschkamp, F., Tischoff, I., Tannapfel, A., Reinacher‐Schick, A., Gerwert, K. B., & Mosig, A. (2023) · The Analyst · doi:10.1039/d3an00166k · Cited by 7
Multivariate Analysis for the Processing of Signals
Beattie, J. R. (2014) · Oil & Gas Science and Technology – Revue d’IFP Energies nouvelles · doi:10.2516/ogst/2013185 · Cited by 7
Image fusion of IR and optical microscopy for mapping of biomolecules in tissue
Jedani, S. A., Whitley, C. A., Ellis, B. G., Triantafyllou, A. G., Smith, C. I., Gunning, P. J., Gardner, P., Risk, J. M., Weightman, P., & Barrett, S. D. (2021) · The Analyst · doi:10.1039/d1an01161h · Cited by 7
Self-citationWang, Y.-D., Gao, Y., Li, X.-L., Tian, G., & Lu, J.-N. (2023) · Analytica Chimica Acta · doi:10.1016/j.aca.2023.341185 · Cited by 6
Serdiuk, V., Shogren, K. L., Kovalenko, T., Rasulev, B., Yaszemski, M. J., Maran, A., & Voronov, A. S. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02858-4 · Cited by 7
Veettil, T. C. P., Alves, D., Vongsvivut, J. P., Sparrow, R. L., Wood, B. R., & Garnier, G. (2023) · The Analyst · doi:10.1039/d2an02001g · Cited by 7
Muthreich, F., Magnussen, E. A., Solheim, J. H., Tafintseva, V., Köhler, A., Seddon, A. W. R., & Zimmermann, B. (2025) · Analytica Chimica Acta · doi:10.1016/j.aca.2025.343879 · Cited by 6
Tiwari, S., Zong, X., Holton, S. E., Prasanth, K. V., & Bhargava, R. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2082347 · Cited by 6
Bergantini, A., de Barros, A. L. F., Domaracka, A., Rothard, H., Boduch, P., & da Silveira, E. F. (2021) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/stab3685 · Cited by 6
A Non-Conventional Platinum Drug against a Non-Small Cell Lung Cancer Line
Silva, J. D. S. E., Marques, J., Santos, I. P., de Carvalho, A. L. M. B., Martins, C. B., Laginha, R. C., de Carvalho, L. A. E. B., & Marques, M. P. M. (2023) · Molecules · doi:10.3390/molecules28041698 · Cited by 6
VIS–NIR spectral signature and quantitative analysis of HeLa and DU145 cell line
Ghani, K. A., Sudik, S., Omar, A. F., Mail, M. H., & Seeni, A. (2019) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2019.117241 · Cited by 6
A de-waxing methodology for scanning probe microscopy
Jedani, S. A., Smith, C. I., Gunning, P. J., Ellis, B. G., Gardner, P., Barrett, S. D., Triantafyllou, A. G., Risk, J. M., & Weightman, P. (2020) · Analytical Methods · doi:10.1039/d0ay00965b · Cited by 6
Self-citationLópez-González, U., Casey, A., & Byrne, H. J. (2020) · Journal of Biophotonics · doi:10.1002/jbio.202000337 · Cited by 6
Self-citationA Comparison between FTIR Spectra from HUKE and SH-SY5Y Cell Lines Grown on Different Substrates
Perna, G., Capozzi, V., & Lasalvia, M. (2020) · Applied Sciences · doi:10.3390/app10248825 · Cited by 6
Space-resolved chemical information from infrared extinction spectra
Hennadige, Y. I. K. D. S. T., Akbar, P. N., & Blümel, R. (2023) · Scientific Reports · doi:10.1038/s41598-023-27619-y · Cited by 7
Improved double-threshold denoising method based on the wavelet transform
Zhang, M., Lu, C., & Liu, C. (2019) · OSA Continuum · doi:10.1364/osac.2.002328 · Cited by 6
Synchrotron Infrared Microspectroscopy for Stem Cell Research
Jiang, Q., Gao, X., Wang, Y., Li, X., Hu, J., & Lü, J. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23179878 · Cited by 6
Schuhmacher, D., Gerwert, K. B., & Mosig, A. (2020) · medRxiv · doi:10.1101/2020.02.27.20028845 · Cited by 6
López-González, U., Casey, A., & Byrne, H. J. (2021) · Journal of Biophotonics · doi:10.1002/jbio.202100058 · Cited by 5
Self-citationLi, Y., Fan, Y., Gao, J., Liu, L.-Z., Lijun, C. A. O., Hu, B., Abula, Z., Xieermaola, Y., Wang, H., Chu, C., et al. (2024) · Food Control · doi:10.1016/j.foodcont.2024.110983 · Cited by 5
Holub, E., Hondl, N., Lin, K., Parikainen, M., Sahlgren, C., Lendl, B., & Ramer, G. (2026) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.5c00132 · Cited by 5
Molecular Pathology via Infrared and Raman Spectral Imaging 1)
Diem, M., Mazur, A. I., Lenau, K., Schubert, J., Fore, J. L., Bird, B., Miljković, M. D., Krafft, C., & Popp, J. (2014) · Wiley eBooks · doi:10.1002/9783527681921.ch3 · Cited by 5
Rieppo, J., Rieppo, L., Saarakkala, S. S., & Jurvelin, J. S. (2011) · InTech eBooks · doi:10.5772/15640 · Cited by 5
Wiechec, A., Opiela, J., Lipiec, E. W., & Kwiatek, W. M. (2013) · Journal of Molecular Structure · doi:10.1016/j.molstruc.2013.06.014 · Cited by 5
Metadata
- Authors
- Bassan, P., Kohler, A., Martens, H., Lee, J., Byrne, H. J., Dumas, P., Gazi, E., Brown, M., Clarke, N., & Gardner, P.
- Affiliations
- University of Manchester (GB)
- Nofima (NO)
- Dublin Institute of Technology (IE)
- Synchrotron SOLEIL (FR)
- Manchester Academic Health Science Centre (GB)
- Corresponding author
- Gardner, Peter
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 135
- Issue
- 2
- Pages
- 268-277
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2167273463
- Cited by
- 375
- References
- 32
- Citations by year
- 2026: 11 · 2025: 13 · 2024: 12 · 2023: 20 · 2022: 20 · 2021: 21 · 2020: 30 · 2019: 22 · 2018: 19 · 2017: 14 · 2016: 23 · 2015: 34 · 2014: 28 · 2013: 39 · 2012: 27
- FWCI
- 13.50
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- Locations
- The Analyst (publishedVersion)
- PubMed (publishedVersion)
- Research Explorer (The University of Manchester) (submittedVersion, other-oa)
- Funders
- Engineering and Physical Sciences Research Council
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Spectroscopy and Quantum Chemical Studies
- Keywords
- infrared spectra, biological cells, amide I band, peak shift
- MeSH terms
- Algorithms, Computer Simulation, Humans, Male, Prostatic Neoplasms, Reference Standards, Tumor Cells, Cultured, Spectroscopy, Fourier Transform Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.