The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Microfluidic lab-on-a-foil for nucleic acid analysis based on isothermal recombinase polymerase amplification (RPA)
Abstract
For the first time we demonstrate a self-sufficient lab-on-a-foil system for the fully automated analysis of nucleic acids which is based on the recently available isothermal recombinase polymerase amplification (RPA). The system consists of a novel, foil-based centrifugal microfluidic cartridge including prestored liquid and dry reagents, and a commercially available centrifugal analyzer for incubation at 37 degrees C and real-time fluorescence detection. The system was characterized with an assay for the detection of the antibiotic resistance gene mecA of Staphylococcus aureus. The limit of detection was <10 copies and time-to-result was <20 min. Microfluidic unit operations comprise storage and release of liquid reagents, reconstitution of lyophilized reagents, aliquoting the sample into < or = 30 independent reaction cavities, and mixing of reagents with the DNA samples. The foil-based cartridge was produced by blow-molding and sealed with a self-adhesive tape. The demonstrated system excels existing PCR based lab-on-a-chip platforms in terms of energy efficiency and time-to-result. Applications are suggested in the field of mobile point-of-care analysis, B-detection, or in combination with continuous monitoring systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Primer-Directed Enzymatic Amplification of DNA with a Thermostable DNA Polymerase
Saiki, R. K., Gelfand, D. H., Stoffel, S., Scharf, S. J., Higuchi, R., Horn, G. T., Mullis, K. B., & Erlich, H. A. (1988) · Science · doi:10.1126/science.2448875 · Cited by 17,719
Saiki, R. K., Scharf, S., Faloona, F., Mullis, K. B., Horn, G. T., Erlich, H. A., & Arnheim, N. (1985) · Science · doi:10.1126/science.2999980 · Cited by 8,956
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
DNA Detection Using Recombination Proteins
Piepenburg, O., Williams, C. H., Stemple, D. L., & Armes, N. A. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040204 · Cited by 2,482
Self-citationMutation detection and single-molecule counting using isothermal rolling-circle amplification
Lizardi, P. M., Huang, X., Zhu, Z., Bray-Ward, P., Thomas, D. C., & Ward, D. C. (1998) · Nature Genetics · doi:10.1038/898 · Cited by 1,442
Nucleic acid sequence-based amplification
Compton, J. (1991) · Nature · doi:10.1038/350091a0 · Cited by 1,344
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Self-citationHelicase‐dependent isothermal DNA amplification
Vincent, M., Xu, Y., & Kong, H. (2004) · EMBO reports · doi:10.1038/sj.embor.7400200 · Cited by 877
Strand displacement amplification—an isothermal,in vitro DNA amplification technique
Walker, G. T., Fraiser, M. S., Schram, J. L., Little, M. C., Nadeau, J. G., & Malinowski, D. P. (1992) · Nucleic Acids Research · doi:10.1093/nar/20.7.1691 · Cited by 850
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Madou, M., Zoval, J., Jia, G., Kido, H., Kim, J., & Kim, N. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095758 · Cited by 568
Guatelli, J. C., Whitfield, K. M., Kwoh, D. Y., Barringer, K. J., Richman, D. D., & Gingeras, T. R. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.5.1874 · Cited by 540
Isothermal in vitro amplification of DNA by a restriction enzyme/DNA polymerase system.
Walker, G. T., Little, M. C., Nadeau, J. G., & Shank, D. D. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.1.392 · Cited by 539
DNA strand exchange proteins a biochemical and physical comparison
Kowalczykowski, S. C. (1998) · Frontiers in Bioscience · doi:10.2741/a304 · Cited by 415
Miniaturised nucleic acid analysis
Auroux, P.-A., Koc, Y., deMello, A., Manz, A., & Day, P. J. R. (2004) · Lab on a Chip · doi:10.1039/b408850f · Cited by 234
Homologous pairing in genetic recombination: complexes of recA protein and DNA.
Shibata, T., Cunningham, R. P., DasGupta, C., & Radding, C. M. (1979) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.76.10.5100 · Cited by 187
Purification and characterization of the T4 bacteriophage uvsX protein.
Formosa, T., & Alberts, B. (1986) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)38499-5 · Cited by 145
Integrated microfluidic tmRNA purification and real-time NASBA device for molecular diagnostics
Dimov, I. K., Garcia-Cordero, J. L., O’Grady, J., Poulsen, C., Viguier, C., Kent, L., Daly, P., Lincoln, B., Maher, M., O’Kennedy, R. J., et al. (2008) · Lab on a Chip · doi:10.1039/b812515e · Cited by 144
Real-Time Nucleic Acid Sequence-Based Amplification in Nanoliter Volumes
Gulliksen, A., Solli, L., Karlsen, F., Rogne, H., Hovig, E. J., Nordstrøm, T., & Sirevåg, R. (2003) · Analytical Chemistry · doi:10.1021/ac034779h · Cited by 133
Hataoka, Y., Zhang, L., Mori, Y., Tomita, N., Notomi, T., & Baba, Y. (2004) · Analytical Chemistry · doi:10.1021/ac035032u · Cited by 98
Mark, D., Metz, T., Haeberle, S., et al. (2009) · Lab on a Chip · doi:10.1039/b914415c · Cited by 82
Self-citationPresent and future of rapid and/or high-throughput methods for nucleic acid testing
Csákó, G. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.07.009 · Cited by 66
NEW MICROBIOLOGY TOOLS FOR PUBLIC HEALTH AND THEIR IMPLICATIONS
Robertson, B. H., & Nicholson, J. K. A. (2004) · Annual Review of Public Health · doi:10.1146/annurev.publhealth.26.021304.144522 · Cited by 54
Lam, L., Sakakihara, S., Ishizuka, K., Takeuchi, S., Arata, H. F., Fujita, H., & Noji, H. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9163-x · Cited by 49
Cited by
Recombinase polymerase amplification: Basics, applications and recent advances
Lobato, I. M., & O'Sullivan, C. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.10.015 · Cited by 1,146
Point-of-care nucleic acid testing for infectious diseases
Niemz, A., Ferguson, T. M., & Boyle, D. S. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.01.007 · Cited by 838
Isothermal nucleic acid amplification technologies for point-of-care diagnostics: a critical review
Craw, P., & Balachandran, W. (2012) · Lab on a Chip · doi:10.1039/c2lc40100b · Cited by 766
Recombinase Polymerase Amplification for Diagnostic Applications
Daher, R. K., Stewart, G., Boissinot, M., & Bergeron, M. G. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.245829 · Cited by 740
Review: a comprehensive summary of a decade development of the recombinase polymerase amplification
Li, J., Macdonald, J., & von Stetten, F. (2019) · The Analyst · doi:10.1039/c8an01621f · Cited by 648
Self-citation
Metadata
- Authors
- Lutz, S., Weber, P., Focke, M., Faltin, B., Hoffmann, J., Müller, C., Mark, D., Roth, G., Munday, P., Armes, N., Piepenburg, O., Zengerle, R., & von Stetten, F.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 7
- Pages
- 887
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2114840438
- Cited by
- 344
- References
- 24
- FWCI
- 12.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.