The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
A facile route for irreversible bonding of plastic-PDMS hybrid microdevices at room temperature
Abstract
Plastic materials do not generally form irreversible bonds with poly(dimethylsiloxane) (PDMS) regardless of oxygen plasma treatment and a subsequent thermal process. In this paper, we perform plastic-PDMS bonding at room temperature, mediated by the formation of a chemically robust amine-epoxy bond at the interfaces. Various plastic materials, such as poly(methylmethacrylate) (PMMA), polycarbonate (PC), polyimide (PI), and poly(ethylene terephthalate) (PET) were adopted as choices for plastic materials. Irrespective of the plastic materials used, the surfaces were successfully modified with amine and epoxy functionalities, confirmed by the surface characterizations such as water contact angle measurements and X-ray photoelectron spectroscopy (XPS), and chemically robust and irreversible bonding was successfully achieved within 1 h at room temperature. The bonding strengths of PDMS with PMMA and PC sheets were measured to be 180 and 178 kPa, respectively, and their assemblies containing microchannel structures endured up to 74 and 84 psi (510 and 579 kPa) of introduced compressed air, respectively, without destroying the microdevices, representing a robust and highly stable interfacial bonding. In addition to microchannel-molded PDMS bonded with flat plastic substrates, microchannel-embossed plastics were also bonded with a flat PDMS sheet, and both types of bonded assemblies displayed sufficiently robust bonding, tolerating an intense influx of liquid whose per-minute injection volume was nearly 1000 to 2000 times higher than the total internal volume of the microchannel used. In addition to observing the bonding performance, we also investigated the potential of surface amine and epoxy functionalities as durable chemical adhesives by observing their storage-time-dependent bonding performances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Determining the optimal PDMS–PDMS bonding technique for microfluidic devices
Eddings, M. A., Johnson, M. A., & Gale, B. K. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/6/067001 · Cited by 567
Fabrication of Plastic Microfluid Channels by Imprinting Methods
Martynova, L., Locascio, L. E., Gaitan, M., Kramer, G. W., Christensen, R. G., & MacCrehan, W. A. (1997) · Analytical Chemistry · doi:10.1021/ac970558y · Cited by 533
Adhesive and Friction Forces between Chemically Modified Silicon and Silicon Nitride Surfaces
Tsukruk, V. V., & Bliznyuk, V. N. (1998) · Langmuir · doi:10.1021/la970367q · Cited by 318
Siqueira Petri, D. F., Wenz, G., Schunk, P., & Schimmel, T. (1999) · Langmuir · doi:10.1021/la981379u · Cited by 238
Construction of microfluidic chips using polydimethylsiloxane for adhesive bonding
Wu, H., Huang, B., & Zare, R. N. (2005) · Lab on a Chip · doi:10.1039/b510494g · Cited by 212
Wettability Interpretation of Oxygen Plasma Modified Poly(methyl methacrylate)
Chai, J., Lu, F., Li, B., & Kwok, D. Y. (2004) · Langmuir · doi:10.1021/la048947s · Cited by 191
Lucio do Lago, C., Torres da Silva, H. D., Neves, C. A., Alves Brito-Neto, J. G., & Fracassi da Silva, J. A. (2003) · Analytical Chemistry · doi:10.1021/ac034437b · Cited by 172
A low temperature surface modification assisted method for bonding plastic substrates
Vlachopoulou, M.-E., Tserepi, A., Pavli, P., Argitis, P., Sanopoulou, M., & Misiakos, K. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/1/015007 · Cited by 164
Heise, A., Menzel, H., Yim, H., Foster, M. D., Wieringa, R. H., Schouten, A. J., Erb, V., & Stamm, M. (1997) · Langmuir · doi:10.1021/la960467g · Cited by 150
Microfluidic channel fabrication by PDMS-interface bonding
Chow, W. W. Y., Lei, K. F., Shi, G., et al. (2005) · Smart Materials and Structures · doi:10.1088/0964-1726/15/1/018 · Cited by 123
Design and Rapid Prototyping of Thin-Film Laminate-Based Microfluidic Devices
Weigl, B. H., Bardell, R. L., Schulte, T., Battrell, F., & Hayenga, J. W. (2001) · Biomedical Microdevices · doi:10.1023/a:1012448412811 · Cited by 97
Novel Poly(dimethylsiloxane) Bonding Strategy via Room Temperature “Chemical Gluing”
Lee, N. Y., & Chung, B. H. (2009) · Langmuir · doi:10.1021/la802823e · Cited by 96
Self-citationWainright, A., Nguyen, U. T. N., Björnson, T. O., & Boone, T. D. (2003) · Electrophoresis · doi:10.1002/elps.200305594 · Cited by 95
Chemically Nanopatterned Surfaces Using Polyelectrolytes and Ultraviolet-Cured Hard Molds
Park, J., Kim, Y. S., & Hammond, P. T. (2005) · Nano Letters · doi:10.1021/nl050592p · Cited by 59
Song, L., Fang, D., Kobos, R. K., Pace, S. J., & Chu, B. (1999) · Electrophoresis · Cited by 40
Lee, N. Y., Lim, J. R., Lee, M. J., Park, S., & Kim, Y. S. (2006) · Langmuir · doi:10.1021/la060305c · Cited by 24
Self-citationLee, N. Y., & Kim, Y. S. (2007) · Macromolecular Rapid Communications · doi:10.1002/marc.200700362 · Cited by 9
Self-citation
Cited by
Park, T.-E., Mustafaoglu, N., Herland, A., Hasselkus, R., Mannix, R., FitzGerald, E. A., Prantil-Baun, R., Watters, A., Henry, O., Benz, M., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-10588-0 · Cited by 594
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Henry, O. Y. F., Villenave, R., Cronce, M. J., Leineweber, W. D., Benz, M. A., & Ingber, D. E. (2017) · Lab on a Chip · doi:10.1039/c7lc00155j · Cited by 482
Lab-on-a-chip devices: How to close and plug the lab?
Temiz, Y., Lovchik, R. D., Kaigala, G. V., & Delamarche, E. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.10.013 · Cited by 475
A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis
Nyein, H. Y. Y., Tai, L.-C., Ngo, Q. P., Chao, M., Zhang, G. B., Gao, W., Bariya, M., Bullock, J., Kim, H., Fahad, H. M., et al. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00961 · Cited by 446
Metadata
- Authors
- Tang, L., & Lee, N. Y.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 10
- Pages
- 1274
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2086700602
- Cited by
- 267
- References
- 19
- FWCI
- 12.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.