Separation and detection of rare cells in a microfluidic disk via negative selection
The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.
Abstract
Cyto-analysis of rare cells often requires separation and detection with each procedure posing substantial challenges. This paper presents a disk-based microfluidic platform for both procedures via an immunomagnetic negative selection process. The microfluidic platform's unique features include a multistage magnetic gradient to trap labeled cells in double trapping areas, drainage of fluid to substantially shorten detection time, and a bin-like regions to capture target cells to facilitate a seamless enumeration process. Proof-of-concept was conducted using MCF7 as target rare cells (stained with anti-cytokeratin-FITC antibodies) spiked into Jurkat Clone E6-1 non-target cells (labeled with anti-CD45-PE and anti-PE BD magnetic beads). Then, mononuclear cells (MNC) from healthy blood donors were mixed with MCF7s, modeling rare cells, and tested in the disk. Results show a non-linear magnetic coupling effect of the multistage magnet substantially increased the trapping efficacy over that of a single magnet, contributing to the depletion rate of Jurkats, which reaches 99.96%. Detection time is extensively shortened by depletion of 95% of non-cell-containing fluid in the collection area. The average yield of detected MCF7 cells is near-constant 60 ± 10% over a wide range of rarity from 10(-3) to 10(-6) and this yield also holds for the MCF7/MNC complex mixture. Comparison with autoMACS and BD IMagnet separators revealed the average yield from the disk (60%) is superior to that of autoMACS (37.3%) and BD IMagnet (48.3%). The advantages of near-constant yield, roughly 30 min of operation, an acceptable level of cell loss, and potentially low cost system should aid in cyto-analysis of rare cells.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Riethdorf, S., Fritsche, H., Müller, V., Rau, T., Schindlbeck, C., Rack, B., Janni, W., Coith, C., Beck, K., Jänicke, F., et al. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-1695 · Cited by 1,338
Isolation by Size of Epithelial Tumor Cells
Vona, G., Sabile, A., Louha, M., Sitruk, V., Romana, S., Schütze, K., Capron, F., Franco, D., Pazzagli, M., Vekemans, M., et al. (2000) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)64706-2 · Cited by 1,069
Circulating tumor cells (CTC) detection: Clinical impact and future directions
Paterlini-Brechot, P., & Benali, N. L. (2007) · Cancer Letters · doi:10.1016/j.canlet.2006.12.014 · Cited by 947
Centrifugal microfluidics for biomedical applications
Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K. (2010) · Lab on a Chip · doi:10.1039/b924109d · Cited by 731
Zheng, S., Lin, H., Liu, J.-Q., Balic, M., Datar, R., Cote, R. J., & Tai, Y.-C. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.064 · Cited by 599
Madou, M., Zoval, J., Jia, G., Kido, H., Kim, J., & Kim, N. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095758 · Cited by 568
Adams, A. A., Okagbare, P. I., Feng, J., Hupert, M. L., Patterson, D., Göttert, J., McCarley, R. L., Nikitopoulos, D., Murphy, M. C., & Soper, S. A. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8015022 · Cited by 521
Sieuwerts, A. M., Kraan, J., Bolt, J., van der Spoel, P., Elstrodt, F., Schutte, M., Martens, J. W. M., Gratama, J.-W., Sleijfer, S., & Foekens, J. A. (2009) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djn419 · Cited by 435
Marker-specific sorting of rare cells using dielectrophoresis
Hu, X., Bessette, P. H., Qian, J., Meinhart, C. D., Daugherty, P. S., & Soh, H. T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507719102 · Cited by 428
Gleghorn, J. P., Pratt, E. D., Denning, D., Liu, H., Bander, N. H., Tagawa, S. T., Nanus, D. M., Giannakakou, P. A., & Kirby, B. J. (2010) · Lab Chip · doi:10.1039/b917959c · Cited by 396
Microdevice for the isolation and enumeration of cancer cells from blood
Tan, S. J., Yobas, L., Lee, G. Y. H., Ong, C. N., & Lim, C. T. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9305-9 · Cited by 362
Rosenberg, R., Gertler, R., Friederichs, J., Fuehrer, K., Dahm, M., Phelps, R., Thorban, S., Nekarda, H., & Siewert, J. R. (2002) · Cytometry · doi:10.1002/cyto.10161 · Cited by 300
Circulating tumor cells (CTCs): Detection methods and their clinical relevance in breast cancer
Mostert, B., Sleijfer, S., Foekens, J. A., & Gratama, J. W. (2009) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2009.03.004 · Cited by 282
Pachmann, K., Camara, O., Kavallaris, A., Krauspe, S., Malarski, N., Gajda, M., Kroll, T., Jörke, C., Hammer, U., Altendorf-Hofmann, A., et al. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.13.6523 · Cited by 280
Aptamer-Based Microfluidic Device for Enrichment, Sorting, and Detection of Multiple Cancer Cells
Xu, Y., Phillips, J. A., Yan, J., Li, Q., Fan, Z. H., & Tan, W. (2009) · Analytical Chemistry · doi:10.1021/ac9012072 · Cited by 275
The force acting on a superparamagnetic bead due to an applied magnetic field
Shevkoplyas, S. S., Siegel, A. C., Westervelt, R. M., Prentiss, M. G., & Whitesides, G. M. (2007) · Lab on a Chip · doi:10.1039/b705045c · Cited by 262
Magnetic Cell Separation: Characterization of Magnetophoretic Mobility
McCloskey, K. E., Chalmers, J. J., & Zborowski, M. (2003) · Analytical Chemistry · doi:10.1021/ac034315j · Cited by 259
Yang, L., Lang, J. C., Balasubramanian, P., Jatana, K. R., Schuller, D., Agrawal, A., Zborowski, M., & Chalmers, J. J. (2009) · Biotechnology and Bioengineering · doi:10.1002/bit.22066 · Cited by 200
Lara, O., Tong, X., Zborowski, M., & Chalmers, J. J. (2004) · Experimental Hematology · doi:10.1016/j.exphem.2004.07.007 · Cited by 199
Gross, H. J., Verwer, B., Houck, D., Hoffman, R. A., & Recktenwald, D. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.2.537 · Cited by 198
Deng, G., Herrler, M., Burgess, D., Manna, E., Krag, D., & Burke, J. F. (2008) · Breast Cancer Research · doi:10.1186/bcr2131 · Cited by 179
Kwon, K. W., Choi, S. S., Lee, S. H., Kim, B., Lee, S. N., Park, M. C., Kim, P., Hwang, S. Y., & Suh, K. Y. (2007) · Lab on a Chip · doi:10.1039/b710054j · Cited by 166
Cell lysis on a microfluidic CD (compact disc)
Kim, J.-T., Jang, S. H., Jia, G., Zoval, J. V., Silva, N. A. D., & Madou, M. J. (2004) · Lab on a Chip · doi:10.1039/b401106f · Cited by 151
Martínez‐Duarte, R., Gorkin, R. A., III, Abi‐Samra, K., & Madou, M. J. (2010) · Lab on a Chip · doi:10.1039/b925456k · Cited by 149
Appropriate biochemical parameters in first-trimester screening for Down syndrome
Cuckle, H., & Lith, J. M. M. V. (1999) · Prenatal Diagnosis · doi:10.1002/(sici)1097-0223(199906)19:6<521::aid-pd578>3.0.co;2-n · Cited by 142
Siegrist, J., Gorkin, R. A., III, Bastien, M., Stewart, G., Peytavi, R., Kido, H., Bergeron, M. G., & Madou, M. J. (2009) · Lab on a Chip · doi:10.1039/b913219h · Cited by 126
Ntouroupi, T. G., Ashraf, S. Q., McGregor, S. B., Turney, B. W., Seppo, A., Kim, Y., Wang, X., Kilpatrick, M. W., Tsipouras, P., Tafas, T., et al. (2008) · British Journal of Cancer · doi:10.1038/sj.bjc.6604545 · Cited by 116
Fehm, T. N., Solomayer, E., Meng, S., Tucker, T. F., Lane, N., Wang, J., & Gebauer, G. (2005) · Cytotherapy · doi:10.1080/14653240510027082 · Cited by 112
Parallel Nanoliter Microfluidic Analysis System
Andersson, P., Jesson, G., Kylberg, G., Ekstrand, G., & Thorsén, G. (2007) · Analytical Chemistry · doi:10.1021/ac061692y · Cited by 108
Integrated siphon-based metering and sedimentation of whole blood on a hydrophilic lab-on-a-disk
Steigert, J., Brenner, T., Grumann, M., Riegger, L., Lutz, S., Zengerle, R., & Ducrée, J. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9076-0 · Cited by 107
Automated microfluidic compact disc (CD) cultivation system of Caenorhabditis elegans
Kim, N., Dempsey, C. M., Zoval, J. V., Sze, J.-Y., & Madou, M. J. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.06.026 · Cited by 94
New Valve and Bonding Designs for Microfluidic Biochips Containing Proteins
Lu, C., Xie, Y., Yang, Y. S., Cheng, M. M., Koh, C. G., Bai, Y., Lee, L. J., & Juang, Y. (2006) · Analytical Chemistry · doi:10.1021/ac0615798 · Cited by 65
Bianchi, D. W., & Hanson, J. W. (2006) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.1080/14767050600676851 · Cited by 65
Circulating Tumor Cells in Metastatic Breast Cancer — Toward Individualized Treatment?
Braun, S., & Marth, C. (2004) · New England Journal of Medicine · doi:10.1056/nejme048163 · Cited by 58
Seppo, A., Frisová, V., Ichetovkin, I. E., Kim, Y., Evans, M. I., Antsaklis, A., Nicolaides, K. H., Tafas, T. P., Tsipouras, P., & Kilpatrick, M. W. (2008) · Prenatal Diagnosis · doi:10.1002/pd.1987 · Cited by 36
Negative selection of hematopoietic progenitor cells by continuous magnetophoresis
Jing, Y., Moore, L. R., Schneider, T., Williams, P. S., Chalmers, J. J., Farag, S. S., Bolwell, B. J., & Zborowski, M. (2007) · Experimental Hematology · doi:10.1016/j.exphem.2006.12.009 · Cited by 33
Kilpatrick, M. W., Tafas, T. P., Evans, M. I., Jackson, L. G., Antsaklis, A., Brambati, B., & Tsipouras, P. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.03.055 · Cited by 32
Tkaczuk, K. H. R., Goloubeva, O. G., Tait, N. S., Feldman, F. S., Tan, M. T., Lum, Z.-P., Lesko, S. A., Echo, D. A. V., & Ts’o, P. O. P. (2007) · Breast Cancer Research and Treatment · doi:10.1007/s10549-007-9771-9 · Cited by 28
A rapid prototyping technique for valves and filters in centrifugal microfluidic devices
LaCroix-Fralish, A., Templeton, E. J., Salin, E. D., & Skinner, C. D. (2009) · Lab on a Chip · doi:10.1039/b908683h · Cited by 26
Tong, X., Xiong, Y., Zborowski, M., Farag, S. S., & Chalmers, J. J. (2007) · Experimental Hematology · doi:10.1016/j.exphem.2007.06.015 · Cited by 21
Pregnancy: Trophoblasts circulating in maternal blood as candidates for prenatal genetic evaluation
Yagel, S., Shpan, P., Dushnik, M., Livni, N., & Shimonovitz, S. (1994) · Human Reproduction · doi:10.1093/oxfordjournals.humrep.a138656 · Cited by 16
Kim, Y., Hong, S. H., Lee, S. H., Lee, K., Yun, S.-O., Kang, Y.-R., Paek, K.-K., Ju, B., & Kim, B. (2007) · Review of Scientific Instruments · doi:10.1063/1.2751414 · Cited by 14
Development of Multistage Magnetic Deposition Microscopy
Nath, P., Strelnik, J., Vasanji, A., Moore, L. R., Williams, P. S., Zborowski, M., Roy, S., & Fleischman, A. J. (2008) · Analytical Chemistry · doi:10.1021/ac8010186 · Cited by 12
Riethdorf, S., & Pantel, K. (2009) · Breast Cancer Research · doi:10.1186/bcr2429 · Cited by 10
Research works printed but not linked: 1
- C. Alix-Panabieres and K.Pantel, Am. Assoc. Cancer Res. 101st Annual Meeting, Education Book, 2010, Apr. 17–21, pp. 179–185
Cited by
Centrifugal microfluidic platforms: advanced unit operations and applications
Strohmeier, O., Keller, M., Schwemmer, F., Zehnle, S., Mark, D., von Stetten, F., Zengerle, R., & Paust, N. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00371c · Cited by 463
Rare cell isolation and analysis in microfluidics
Chen, Y., Li, P., Huang, P.-H., Xie, Y., Mai, J. D., Wang, L., Nguyen, N.-T., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc90136j · Cited by 307
Microfluidic approaches for cancer cell detection, characterization, and separation
Chen, J., Li, J., & Sun, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc21273k · Cited by 301
Expansion of CTCs from early stage lung cancer patients using a microfluidic co-culture model
Zhang, Z., Shiratsuchi, H., Lin, J., Chen, G., Reddy, R. M., Azizi, E., Fouladdel, S., Chang, A. C., Lin, L., Jiang, H., et al. (2014) · Oncotarget · doi:10.18632/oncotarget.2592 · Cited by 207
“Technologies to recover rare CTCs include immunoaffinity based methods, size based filtration, dielectrophoresis, negative depletion and inertial based methods [13–24].”
Enrichment, detection and clinical significance of circulating tumor cells
Arya, S. K., Lim, B., & Rahman, A. R. A. (2013) · Lab on a Chip · doi:10.1039/c3lc00009e · Cited by 168
Metadata
- Authors
- Chen, C.-L., Chen, K.-C., Pan, Y.-C., Lee, T.-P., Hsiung, L.-C., Lin, C.-M., Chen, C.-Y., Lin, C.-H., Chiang, B.-L., & Wo, A. M.
- Affiliations
- National Taiwan University (TW)
- Corresponding author
- Wo, Andrew M.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 3
- Pages
- 474-483
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2077346543
- Cited by
- 72
- References
- 47
- Citations by year
- 2025: 1 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 3 · 2019: 8 · 2018: 3 · 2017: 4 · 2016: 10 · 2015: 7 · 2014: 7 · 2013: 8 · 2012: 11
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Council
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- rare cell detection, negative selection, immunomagnetic separation, magnetic gradient, MCF-7 cells, mononuclear cells, cell counting
- MeSH terms
- Antibodies, Monoclonal, Humans, Keratins, Leukocytes, Leukocyte Common Antigens, Immunomagnetic Separation, Jurkat Cells, Cell Line, Tumor, Microfluidic Analytical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.