Separation and detection of rare cells in a microfluidic disk via negative selection
The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.
Abstract
Cyto-analysis of rare cells often requires separation and detection with each procedure posing substantial challenges. This paper presents a disk-based microfluidic platform for both procedures via an immunomagnetic negative selection process. The microfluidic platform's unique features include a multistage magnetic gradient to trap labeled cells in double trapping areas, drainage of fluid to substantially shorten detection time, and a bin-like regions to capture target cells to facilitate a seamless enumeration process. Proof-of-concept was conducted using MCF7 as target rare cells (stained with anti-cytokeratin-FITC antibodies) spiked into Jurkat Clone E6-1 non-target cells (labeled with anti-CD45-PE and anti-PE BD magnetic beads). Then, mononuclear cells (MNC) from healthy blood donors were mixed with MCF7s, modeling rare cells, and tested in the disk. Results show a non-linear magnetic coupling effect of the multistage magnet substantially increased the trapping efficacy over that of a single magnet, contributing to the depletion rate of Jurkats, which reaches 99.96%. Detection time is extensively shortened by depletion of 95% of non-cell-containing fluid in the collection area. The average yield of detected MCF7 cells is near-constant 60 ± 10% over a wide range of rarity from 10(-3) to 10(-6) and this yield also holds for the MCF7/MNC complex mixture. Comparison with autoMACS and BD IMagnet separators revealed the average yield from the disk (60%) is superior to that of autoMACS (37.3%) and BD IMagnet (48.3%). The advantages of near-constant yield, roughly 30 min of operation, an acceptable level of cell loss, and potentially low cost system should aid in cyto-analysis of rare cells.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Circulating Tumor Cells, Disease Progression, and Survival in Metastatic Breast Cancer
Cristofanilli, M., Budd, G. T., Ellis, M. J., Stopeck, A., Matera, J., Miller, M. C., Reuben, J. M., Doyle, G. V., Allard, W. J., Terstappen, L. W. M. M., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa040766 · Cited by 4,593
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Riethdorf, S., Fritsche, H., Müller, V., Rau, T., Schindlbeck, C., Rack, B., Janni, W., Coith, C., Beck, K., Jänicke, F., et al. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-06-1695 · Cited by 1,338
Isolation by Size of Epithelial Tumor Cells
Vona, G., Sabile, A., Louha, M., Sitruk, V., Romana, S., Schütze, K., Capron, F., Franco, D., Pazzagli, M., Vekemans, M., et al. (2000) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)64706-2 · Cited by 1,069
Circulating tumor cells (CTC) detection: Clinical impact and future directions
Paterlini-Brechot, P., & Benali, N. L. (2007) · Cancer Letters · doi:10.1016/j.canlet.2006.12.014 · Cited by 947
Centrifugal microfluidics for biomedical applications
Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K. (2010) · Lab on a Chip · doi:10.1039/b924109d · Cited by 731
Zheng, S., Lin, H., Liu, J.-Q., Balic, M., Datar, R., Cote, R. J., & Tai, Y.-C. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.05.064 · Cited by 599
Madou, M., Zoval, J., Jia, G., Kido, H., Kim, J., & Kim, N. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095758 · Cited by 568
Adams, A. A., Okagbare, P. I., Feng, J., Hupert, M. L., Patterson, D., Göttert, J., McCarley, R. L., Nikitopoulos, D., Murphy, M. C., & Soper, S. A. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8015022 · Cited by 521
Sieuwerts, A. M., Kraan, J., Bolt, J., van der Spoel, P., Elstrodt, F., Schutte, M., Martens, J. W. M., Gratama, J.-W., Sleijfer, S., & Foekens, J. A. (2009) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djn419 · Cited by 435
Research works printed but not linked: 1
- C. Alix-Panabieres and K.Pantel, Am. Assoc. Cancer Res. 101st Annual Meeting, Education Book, 2010, Apr. 17–21, pp. 179–185
Cited by
Centrifugal microfluidic platforms: advanced unit operations and applications
Strohmeier, O., Keller, M., Schwemmer, F., Zehnle, S., Mark, D., von Stetten, F., Zengerle, R., & Paust, N. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00371c · Cited by 463
Rare cell isolation and analysis in microfluidics
Chen, Y., Li, P., Huang, P.-H., Xie, Y., Mai, J. D., Wang, L., Nguyen, N.-T., & Huang, T. J. (2014) · Lab on a Chip · doi:10.1039/c3lc90136j · Cited by 307
Microfluidic approaches for cancer cell detection, characterization, and separation
Chen, J., Li, J., & Sun, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc21273k · Cited by 301
Expansion of CTCs from early stage lung cancer patients using a microfluidic co-culture model
Zhang, Z., Shiratsuchi, H., Lin, J., Chen, G., Reddy, R. M., Azizi, E., Fouladdel, S., Chang, A. C., Lin, L., Jiang, H., et al. (2014) · Oncotarget · doi:10.18632/oncotarget.2592 · Cited by 207
“Technologies to recover rare CTCs include immunoaffinity based methods, size based filtration, dielectrophoresis, negative depletion and inertial based methods [13–24].”
Enrichment, detection and clinical significance of circulating tumor cells
Arya, S. K., Lim, B., & Rahman, A. R. A. (2013) · Lab on a Chip · doi:10.1039/c3lc00009e · Cited by 168
Microfluidic technologies for circulating tumor cell isolation
Cho, H., Kim, J., Song, H., Sohn, K. Y., Jeon, M., & Han, K.-H. (2018) · The Analyst · doi:10.1039/c7an01979c · Cited by 167
Hyun, K.-A., Kwon, K., Han, H., Kim, S. I., & Jung, H. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.07.021 · Cited by 126
“For example, a disk-type microfluidic platform collected breast cancer cells (MCF-7 cell lines) near the outer rim by capturing immunomagnetically labeled non-target cells using a multistage magnet configuration (Chen et al., 2011).”
MethodMicrofluidics and cancer: are we there yet?
Zhang, Z., & Nagrath, S. (2013) · Biomedical Microdevices · doi:10.1007/s10544-012-9734-8 · Cited by 144
Basic Principles and Recent Advances in Magnetic Cell Separation
Frénéa‐Robin, M., & Marchalot, J. (2022) · Magnetochemistry · doi:10.3390/magnetochemistry8010011 · Cited by 133
Advances and critical concerns with the microfluidic enrichments of circulating tumor cells
Hyun, K.-A., & Jung, H.-I. (2014) · Lab Chip · doi:10.1039/c3lc50582k · Cited by 114
Large-Volume Microfluidic Cell Sorting for Biomedical Applications
Warkiani, M. E., Wu, L., Tay, A. K. P., & Han, J. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040818 · Cited by 121
Hyun, K.-A., Lee, T. Y., & Jung, H.-I. (2013) · Analytical Chemistry · doi:10.1021/ac3037766 · Cited by 102
Self-citationCentrifugal microfluidics for cell analysis
Burger, R., Kirby, D., Glynn, M. T., Nwankire, C. E., O'Sullivan, M., Siegrist, J., Kinahan, D. J., Aguirre, G. R., Kijanka, G. S., Gorkin, R. A., III, et al. (2012) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2012.06.002 · Cited by 99
“Chen and colleagues developed a system based on negative selection to separate MCF7 cancer cells from a background of Jurkat cells [27].”
BackgroundTwo-stage microfluidic chip for selective isolation of circulating tumor cells (CTCs)
Hyun, K.-A., Lee, T. Y., Lee, S. H., & Jung, H. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.019 · Cited by 99
Self-citationAn integrated microfluidic chip for one-step isolation of circulating tumor cells
Lee, T. Y., Hyun, K.-A., Kim, S.-I., & Jung, H.-I. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.05.163 · Cited by 94
Self-citationHuang, Q., Wang, Y., Chen, X., Wang, Y., Li, Z., Du, S., Wang, L., & Chen, S. (2017) · Nanotheranostics · doi:10.7150/ntno.22091 · Cited by 96
“negative enrichment approach, using a disk-based microchip for the immunomagnetic negative separation of rare cells [101].”
MethodPast, Present, and Future of Affinity-based Cell Separation Technologies
Bacon, K. B., Lavoie, R. A., Rao, B. M., Daniele, M. A.-A., & Menegatti, S. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.05.004 · Cited by 87
Tang, W., Jiang, D., Li, Z., Zhu, L., Shi, J., Yang, J., & Xiang, N. (2018) · Electrophoresis · doi:10.1002/elps.201800361 · Cited by 79
Mathematical modeling and computational analysis of centrifugal microfluidic platforms: a review
Madadelahi, M., Acosta-Soto, L., Hosseini, S., Martinez-Chapa, S. O., & Madou, M. J. (2020) · Lab on a Chip · doi:10.1039/c9lc00775j · Cited by 68
Electrical Detection Method for Circulating Tumor Cells Using Graphene Nanoplates
Han, S.-I., & Han, K.-H. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03147 · Cited by 59
Enhancement of microfluidic particle separation using cross-flow filters with hydrodynamic focusing
Chiu, Y.-Y., Huang, C.-K., & Lu, Y. (2016) · Biomicrofluidics · doi:10.1063/1.4939944 · Cited by 60
Shamloo, A., Naghdloo, A., & Besanjideh, M. (2021) · Scientific Reports · doi:10.1038/s41598-021-81661-2 · Cited by 58
Kuo, C.-T., Chiang, C.-L., Yun-Ju Huang, R., Lee, H., & Wo, A. M. (2012) · NPG Asia Materials · doi:10.1038/am.2012.50 · Cited by 55
Self-citationHandling and analysis of cells and bioparticles on centrifugal microfluidic platforms
Burger, R., & Ducrée, J. (2012) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.12.28 · Cited by 56
Immunomagnetic nanoparticle-based assays for detection of biomarkers
Lee, K. H., Park, H. D., & Hwang, M. P. (2013) · International Journal of Nanomedicine · doi:10.2147/ijn.s51893 · Cited by 62
Recent advances in microfluidic methods in cancer liquid biopsy
Iliescu, F. S., Poenar, D. P., Yu, F., Ni, M., Chan, K. H., Cima, I., Taylor, H. K., Cima, I., & Iliescu, C. (2019) · Biomicrofluidics · doi:10.1063/1.5087690 · Cited by 51
Lin, H.-C., Hsu, H., Hsieh, C., Wang, H., Huang, C.-Y., Wu, M., & Tseng, C. (2013) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.01.018 · Cited by 51
“The surface area to void volume ratio was 61 cm−1 which is larger than such ratio reported in previous studies [18,26].”
MethodResultMicrofluidic Screening of Circulating Tumor Biomarkers toward Liquid Biopsy
Hao, N., & Zhang, J. X. J. (2017) · Separation and Purification Reviews · doi:10.1080/15422119.2017.1320763 · Cited by 44
“The latter type of immunomagnetic beads–based negative selection methods can be performed in many forms for collecting CTCs, such as multistage concentriccircular magnet on microfluidic disk (101), fluorescent-activated cell sorting (102), and microslit membrane (103, 104).”
MethodLiu, Q., Zhang, X., Chen, L., Yao, Y., Ke, S., Wang, Z., Yang, Z., & Sui, G. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.05.044 · Cited by 40
Fulcrand, R., Bancaud, A., Escriba, C., He, Q., Charlot, S., Boukabache, A., & Gué, A. M. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.08.011 · Cited by 40
Kang, H., Kim, J., Cho, H., & Han, K.-H. (2019) · Micromachines · doi:10.3390/mi10060386 · Cited by 38
“In addition, because negative methods do not use antibodies specific to CTCs, they are suitable for downstream analyses, such as genetic assays, CTC culture, and xenografts [21,22].”
BackgroundLi, P., Gao, Y., & Pappas, D. (2012) · Analytical Chemistry · doi:10.1021/ac302002a · Cited by 35
Borberg, E., Zverzhinetsky, M., Krivitsky, A., Kosloff, A., Heifler, O., Degabli, G., Soroka, H. P., Satchi‐Fainaro, R., Burstein, L., Reuveni, S., et al. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b01323 · Cited by 33
Sampling techniques for single-cell electrophoresis
Cecala, C., & Sweedler, J. V. (2012) · The Analyst · doi:10.1039/c2an16211c · Cited by 32
Microfluidic Devices for Circulating Tumor Cells Isolation and Subsequent Analysis
Khamenehfar, A., & Li, P. C. H. (2016) · Current Pharmaceutical Biotechnology · doi:10.2174/1389201017666160301103509 · Cited by 30
Bu, J., Kang, Y., Kim, Y. J., Cho, Y.-H., Chang, H. J., Kim, H., Moon, B.-I., & Kim, H. G. (2016) · Lab on a Chip · doi:10.1039/c6lc01179a · Cited by 30
Xue, M., Xiang, A., Guo, Y., Wang, L., Wang, R., Wang, W., Ji, G., & Lu, Z. (2019) · RSC Advances · doi:10.1039/c9ra08285a · Cited by 26
An integrated on-chip platform for negative enrichment of tumour cells
Gourikutty, S. B. N., Chang, C.-P., & Poenar, D. P. (2016) · Journal of Chromatography B · doi:10.1016/j.jchromb.2016.06.016 · Cited by 26
Circulating Tumor Cells as a Promising Tool for Early Detection of Hepatocellular Carcinoma
Salehi, M., Miri-Lavasani, Z., Alikhani, H. K., Shokouhian, B., Hassan, M., Najimi, M., & Vosough, M. (2023) · Cells · doi:10.3390/cells12182260 · Cited by 24
“Therefore, this method is suitable for downstream analyses such as genetic assays, CTC culture, and xenografts [59,60].”
Noninvasive prenatal diagnosis
Cheng, W.-L., Hsiao, C., Tseng, H.-W., & Lee, T. (2015) · Taiwanese Journal of Obstetrics and Gynecology · doi:10.1016/j.tjog.2015.05.002 · Cited by 36
Self-citationDetection of Circulating Endothelial Cells via a Microfluidic Disk
Chen, K.-C., Lee, T., Pan, Y.-C., Chiang, C., Chen, C., Yang, Y., Chiang, B., Lee, H., & Wo, A. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.157404 · Cited by 22
Self-citationMicrochips and their Significance in Isolation of Circulating Tumor Cells and Monitoring of Cancers
Sahmani, M., Vatanmakanian, M., Goudarzi, M., Mobarra, N., & Azad, M. (2016) · Asian Pacific Journal of Cancer Prevention · doi:10.7314/apjcp.2016.17.3.879 · Cited by 23
“Currently, new generation of chips in micro-scales have been developed which are able to collect the magnetically-labeled CTCs from blood samples (Chen et al., 2011b).”
BackgroundHao, N., & Zhang, J. X. J. (2019) · Biomicrofluidics · doi:10.1063/1.5119052 · Cited by 21
Lombodorj, B., Tseng, H. C., Chang, H., Lu, Y., Tumurpurev, N., Lee, C., Batdemberel, G., Wu, R., & Tseng, F. (2020) · Micromachines · doi:10.3390/mi11030275 · Cited by 20
“hand, microfluidics have been demonstrated to separate particles or cells, including pinched flow fractionation (PFF) [5–9], cross-flow filtration [10–14], microfluidic disk [15], laminar vortices [16– 18], centrifugation/inertial focusing [19–21], and Dean flow [22–25].”
BackgroundChen, Y., Shen, M., Zhu, Y., & Xu, Y. (2019) · Lab on a Chip · doi:10.1039/c9lc00043g · Cited by 20
Siphon-Induced Droplet Break-Off for Enhanced Mixing on a Centrifugal Platform
Burger, R., Kinahan, D. J., Cayron, H., Reis, N., da Fonseca, J. G., & Ducrée, J. (2019) · Inventions · doi:10.3390/inventions5010001 · Cited by 18
Fundamentals of affinity cell separations
Zhang, Y., Lyons, V., & Pappas, D. (2017) · Electrophoresis · doi:10.1002/elps.201700311 · Cited by 20
Advances in precise cell manipulation
Ma, Y., Liang, Z., Chen, Y., & Wang, J. (2025) · Droplet · doi:10.1002/dro2.149 · Cited by 16
Microfluidic Approaches for Cancer Cell Separation: Review
Saeed, O., Li, R., & Deng, Y. (2014) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2014.712098 · Cited by 16
“proposed DEP flow-field fractionation (DEP-FFF) wherein DEP forces are generated to levitate suspended cells to different equilibrium heights within amicrofluidic chamber, based on variations of cells’ electrical properties [94].”
BackgroundChen, C., Chen, Y.-A., Liu, Y.-J., & Yao, D. (2014) · Lab on a Chip · doi:10.1039/c3lc51345a · Cited by 17
Self-citationCell Elasticity-based Microfluidic Label-free Isolation of Metastatic Tumor Cells
Islam, M. (2014) · Journal of Advances in Medicine and Medical Research · doi:10.9734/bjmmr/2014/7392 · Cited by 11
“Magnetic bead based cell separation techniques have been shown to isolate and enumerate CTCs from blood samples with high efficiency, specificity and viability [4-8].”
BackgroundTowards Single-Cell Analysis For Pharmacokinetics
Luo, Y., Liu, C., Qu, Y., & Fang, N. (2012) · Bioanalysis · doi:10.4155/bio.11.325 · Cited by 11
A Novel Magnetic Active Valve for Lab-on-CD Technology
Carpentras, D., Kulinsky, L., & Madou, M. J. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2015.2395379 · Cited by 11
Enumeration and viability of rare cells in a microfluidic disk via positive selection approach
Chen, K.-C., Pan, Y.-C., Chen, C., Lin, C., Huang, C., & Wo, A. M. (2012) · Analytical Biochemistry · doi:10.1016/j.ab.2012.07.007 · Cited by 11
“The enumeration of rare cells with negative selection configuration also has been demonstrated [19].”
BackgroundSelf-citationKuo, C., Wang, J.-Y., Lu, S.-R., Lai, Y., Chang, H., Hsieh, J., Wo, A. M., Chen, B. P. C., Lu, J., & Lee, H. (2019) · Scientific Reports · doi:10.1038/s41598-019-46502-3 · Cited by 10
Self-citationKalasin, S., Browne, E. P., Arcaro, K. F., & Santore, M. M. (2017) · RSC Advances · doi:10.1039/c7ra01217a · Cited by 7
Sinusoidal Microchannels with High Aspect Ratios for CTC Selection and Analysis
Jackson, J. M., Witek, M. A., & Soper, S. A. (2016) · Wiley eBooks · doi:10.1002/9781119244554.ch4 · Cited by 5
Lin, S., Lu, L.-K., Hsu, W.-F., Peng, W.-C., Tseng, H.-W., Li, C.-C., Chen, C., Huang, G.-S., Lee, C., & Wo, A. M. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.2c04260 · Cited by 5
Self-citationCentrifugal Filter Device for Detection of Rare Cells With Immuno-Binding
Chen, C., Chen, Y., & Yao, D. (2015) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2015.2485298 · Cited by 5
Self-citationAzizi, E., Nagrath, S., Kozminsky, M., & Wicha, M. S. (2016) · Current cancer research · doi:10.1007/978-1-4939-3363-1_5 · Cited by 4
Detection, manipulation and post processing of circulating tumor cells using optical techniques
Bakhtiaridoost, S., Habibiyan, H., & Ghafoorifard, H. (2015) · Modern Physics Letters B · doi:10.1142/s0217984915300100 · Cited by 3
Spot Immunomagnetic Enrichment Device for Rapid Detection of Pathogens in Peripheral Blood
Singh, S. K., Upadhyay, M., Pandey, V., Vivekanandan, P., Gupta, S., & Elangovan, R. (2016) · Advanced Materials Technologies · doi:10.1002/admt.201600101 · Cited by 2
Ghafouri, V., & Badieirostami, M. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-021-02505-z · Cited by 2
Ghafouri, V., Badieirostami, M., & Fathipour, M. (2022) · Bioimpacts · doi:10.34172/bi.2022.23393 · Cited by 1
Rare cells detection by selective enrichment with a novel multilayer concentric filter device
Chen, C., Chen, Y., & Yao, D. (2014) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2014.6908838
“Many approaches as immune-magnetic enrichment [1], flow cytometry sorting [2], density centrifugation [3], micro-structural constrain array [4] and size-based separation [5] had been investigated to isolate rare cells.”
BackgroundSelf-citationCapture and Analysis of Cells Using Magnetic Beads
Dominguez, A. (2011) · OPUS - Open Portal to University Scholarship (Governors State University)
Dropletization of Bioreactions
Karimiani, E. G., Markey, A., & Day, P. J. (2013) · CRC Press eBooks · doi:10.1201/b14930-15
Extracellular and intracellular phenomena in microfluidic flow
Vickers, D. A. L. (2012) · Digital Repository Service (Northeastern University) · doi:10.17760/d20002933
Zhang, Z. (2016) · Deep Blue (University of Michigan)
Polymer Microsystems for the Enrichment of Circulating Tumor Cells and their Clinical Demonstration
Kamande, J. W. (2013) · Louisiana State University · doi:10.31390/gradschool_dissertations.2652
The Dropletisation of Bio-Reactions
Karimiani, E. G., Markey, A., & Day, P. J. (2012) · Springer eBooks · doi:10.1007/978-1-4614-3265-4_6
Development of tools for the precise control of biological parameters via microfluidics
Giuliano, C. B. (2022) · theses.fr (ABES) · doi:10.70675/724b14f8zc300z4513z84a4z1a8d04fa7212
Descamps, L. (2021) · theses.fr (ABES) · doi:10.70675/dcaf8063z1ab2z49c6z9cfdzfe1a79cfe835
Metadata
- Authors
- Chen, C.-L., Chen, K.-C., Pan, Y.-C., Lee, T.-P., Hsiung, L.-C., Lin, C.-M., Chen, C.-Y., Lin, C.-H., Chiang, B.-L., & Wo, A. M.
- Affiliations
- National Taiwan University (TW)
- Corresponding author
- Wo, Andrew M.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 3
- Pages
- 474-483
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2077346543
- Cited by
- 72
- References
- 47
- Citations by year
- 2025: 1 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 3 · 2019: 8 · 2018: 3 · 2017: 4 · 2016: 10 · 2015: 7 · 2014: 7 · 2013: 8 · 2012: 11
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Council
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Innovative Microfluidic and Catalytic Techniques Innovation
- Keywords
- rare cell detection, negative selection, immunomagnetic separation, magnetic gradient, MCF-7 cells, mononuclear cells, cell counting
- MeSH terms
- Antibodies, Monoclonal, Humans, Keratins, Leukocytes, Leukocyte Common Antigens, Immunomagnetic Separation, Jurkat Cells, Cell Line, Tumor, Microfluidic Analytical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.