The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Continuous separation of breast cancer cells from blood samples using multi-orifice flow fractionation (MOFF) and dielectrophoresis (DEP)
Open accessAbstract
Circulating tumor cells (CTCs) are highly correlated with the invasive behavior of cancer, so their isolations and quantifications are important for biomedical applications such as cancer prognosis and measuring the responses to drug treatments. In this paper, we present the development of a microfluidic device for the separation of CTCs from blood cells based on the physical properties of cells. For use as a CTC model, we successfully separated human breast cancer cells (MCF-7) from a spiked blood cell sample by combining multi-orifice flow fractionation (MOFF) and dielectrophoretic (DEP) cell separation technique. Hydrodynamic separation takes advantage of the massive and high-throughput filtration of blood cells as it can accommodate a very high flow rate. DEP separation plays a role in precise post-processing to enhance the efficiency of the separation. The serial combination of these two different sorting techniques enabled high-speed continuous flow-through separation without labeling. We observed up to a 162-fold increase in MCF-7 cells at a 126 µL min(-1) flow rate. Red and white blood cells were efficiently removed with separation efficiencies of 99.24% and 94.23% respectively. Therefore, we suggest that our system could be used for separation and detection of CTCs from blood cells for biomedical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Allard, W. J., Matera, J., Miller, M. C., Repollet, M., Connelly, M. C., Rao, C., Tibbe, A. G. J., Uhr, J. W., & Terstappen, L. W. M. M. (2004) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-0378 · Cited by 2,542
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Di Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Detection, clinical relevance and specific biological properties of disseminating tumour cells
Pantel, K., Brakenhoff, R. H., & Brandt, B. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2375 · Cited by 1,118
ELECTRICAL FORCES FOR MICROSCALE CELL MANIPULATION
Voldman, J. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095739 · Cited by 892
Separation of human breast cancer cells from blood by differential dielectric affinity.
Becker, F. F., Wang, X. B., Huang, Y., Pethig, R., Vykoukal, J., & Gascoyne, P. R. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.3.860 · Cited by 680
Adams, A. A., Okagbare, P. I., Feng, J., Hupert, M. L., Patterson, D., Göttert, J., McCarley, R. L., Nikitopoulos, D., Murphy, M. C., & Soper, S. A. (2008) · Journal of the American Chemical Society · doi:10.1021/ja8015022 · Cited by 521
Equilibrium Separation and Filtration of Particles Using Differential Inertial Focusing
Di Carlo, D., Edd, J. F., Irimia, D., Tompkins, R. G., & Toner, M. (2008) · Analytical Chemistry · doi:10.1021/ac702283m · Cited by 413
A rare-cell detector for cancer
Krivacic, R. T., Ladanyi, A., Curry, D. N., Hsieh, H. B., Kuhn, P., Bergsrud, D. E., Kepros, J. F., Barbera, T., Ho, M. Y., Chen, L. B., et al. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404036101 · Cited by 340
Rao, C., Chianese, D., Doyle, G., Miller, M., Russell, T., Sanders, R., & Terstappen, L. (2005) · International Journal of Oncology · doi:10.3892/ijo.27.1.49 · Cited by 327
DETECTION OF DISSEMINATED TUMOR CELLS IN PERIPHERAL BLOOD
Zieglschmid, V., Hollmann, C., & Böcher, O. (2005) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408360590913696 · Cited by 272
Park, J.-S., Song, S.-H., & Jung, H.-I. (2009) · Lab Chip · doi:10.1039/b813952k · Cited by 239
Self-citationIsolation of tumor cells using size and deformation
Mohamed, H., Murray, M., Turner, J. N., & Caggana, M. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.05.036 · Cited by 208
Circulating tumor cells: the ‘leukemic phase’ of solid cancers
Mocellin, S., Keilholz, U., Rossi, C. R., & Nitti, D. (2006) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2006.01.006 · Cited by 196
Georgakoudi, I., Solban, N., Novak, J., Rice, W. L., Wei, X., Hasan, T., & Lin, C. P. (2004) · Cancer Research · doi:10.1158/0008-5472.can-04-1058 · Cited by 187
Deng, G., Herrler, M., Burgess, D., Manna, E., Krag, D., & Burke, J. F. (2008) · Breast Cancer Research · doi:10.1186/bcr2131 · Cited by 179
Park, J.-S., & Jung, H. (2009) · Analytical Chemistry · doi:10.1021/ac9005765 · Cited by 155
Self-citationMicrosystems for isolation and electrophysiological analysis of breast cancer cells from blood
Han, K.-H., Han, A., & Frazier, A. B. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.024 · Cited by 119
Kahn, H. J., Presta, A., Yang, L., et al. (2004) · Breast Cancer Research and Treatment · doi:10.1023/b:brea.0000036897.92513.72 · Cited by 108
Kim, U., & Soh, H. T. (2009) · Lab on a Chip · doi:10.1039/b903950c · Cited by 105
Moon, H., Nam, Y., Park, J. C., & Jung, H. (2009) · Environmental Science & Technology · doi:10.1021/es900078z · Cited by 59
Self-citationCirculating Tumor Cells: Detection Methods and Potential Clinical Application in Breast Cancer
Kim, S. I., & Jung, H. (2010) · Journal of Breast Cancer · doi:10.4048/jbc.2010.13.2.125 · Cited by 25
Self-citation
Cited by
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Fundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017
Amini, H., Lee, W., & Di Carlo, D. (2014) · Lab on a Chip · doi:10.1039/c4lc00128a · Cited by 722
Molecular analysis of circulating tumour cells—biology and biomarkers
Krebs, M. G., Metcalf, R. L., Carter, L., Brady, G., Blackhall, F. H., & Dive, C. (2014) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.253 · Cited by 622
Ultra-fast, label-free isolation of circulating tumor cells from blood using spiral microfluidics
Warkiani, M. E., Khoo, B. L., Wu, L., Tay, A. K. P., Bhagat, A. A. S., Han, J., & Lim, C. T. (2016) · Nature Protocols · doi:10.1038/nprot.2016.003 · Cited by 548
Metadata
- Authors
- Moon, H.-S., Kwon, K., Kim, S.-I., Han, H., Sohn, J., Lee, S., & Jung, H.-I.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 6
- Pages
- 1118
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2125051097
- Cited by
- 437
- References
- 23
- FWCI
- 19.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.