Highly sensitive fluorescence detection system for microfluidic lab-on-a-chip
Abstract
We demonstrate a compact, low cost and practical fluorescence detection system for lab-on-a-chip applications. The system comprises a commercially available InGaN light emitting diode (501 nm) as light source, an organic or silicon photodiode detector, absorptive dye coated colour filters and linear and reflective polarisers. An injection moulded polystyrene microfluidic chip is used as the platform for fluorescence immunoassays for cardiac markers myoglobin and CK-MB. The optical limit of detection (LOD) is measured using a TransFluoSphere® suspension at 5.6 × 10(4) beads µl(-1) which can be equated to ∼3 nM fluorescein equivalent concentration. The LOD for the human plasma immunoassays is measured as 1.5 ng ml(-1) for both myoglobin and CK-MB.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ryu et al. demonstrated a compact, inexpensive, and practical fluorescence detection system for lab-on-a-chip applications that can detect the cardiac markers myoglobin and CK-MB from human plasma.
“Interesting and useful is also the research by Ryu et al. [36] where they demonstrated a compact, inexpensive, and practical fluorescence detection system for lab-on-a-chip applications, consisting of 501 nm commercially available InGaN LED, an organic or silicon photodiode, absorptive dye-coated color filters, polarizers, and an injected polystyrene microfluidic chip.”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [36]
Cites
Kim, Y., Choulis, S. A., Nelson, J., et al. (2005) · Applied Physics Letters · doi:10.1063/1.1861123 · Cited by 676 · see citing works
Fast, Ultrasensitive Virus Detection Using a Young Interferometer Sensor
Ymeti, A., Greve, J. W. M., Lambeck, P., et al. (2006) · Nano Letters · doi:10.1021/nl062595n · Cited by 289 · see citing works
Composition and annealing effects in polythiophene/fullerene solar cells
Kim, Y., Choulis, S. A., Nelson, J., et al. (2005) · Journal of Materials Science · doi:10.1007/s10853-005-0568-0 · Cited by 214 · see citing works
Whitehead, K. S., Grell, M., Bradley, D. D. C., et al. (2000) · Applied Physics Letters · doi:10.1063/1.126525 · Cited by 214 · see citing works
Self-citationLiu, G. L., & Lee, L. P. (2005) · Applied Physics Letters · doi:10.1063/1.2031935 · Cited by 213 · see citing works
Free-Solution, Label-Free Molecular Interactions Studied by Back-Scattering Interferometry
Bornhop, D. J., Latham, J. C., Kussrow, A. K., et al. (2007) · Science · doi:10.1126/science.1146559 · Cited by 204 · see citing works
Liu, P., Seo, T. S., Beyor, N., et al. (2007) · Analytical Chemistry · doi:10.1021/ac061961k · Cited by 185 · see citing works
An integrated fluorescence detection system for lab-on-a-chip applications
Novak, L., Neužil, P., Pipper, J., et al. (2006) · Lab on a Chip · doi:10.1039/b611745g · Cited by 176 · see citing works
Pais, A., Banerjee, A., Klotzkin, D. J., et al. (2008) · Lab on a Chip · doi:10.1039/b715143h · Cited by 172 · see citing works
Hofmann, O., Wang, X., Cornwell, A., et al. (2006) · Lab on a Chip · doi:10.1039/b603678c · Cited by 147 · see citing works
Self-citationThin-film organic photodiodes as integrated detectors for microscale chemiluminescence assays
Hofmann, O., Miller, P., Sullivan, P. J., Jones, T. S., de Mello, J. C., Bradley, D. D. C., & deMello, A. J. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2004.10.005 · Cited by 138 · see citing works
Self-citationFeltis, B., Sexton, B. A., Glenn, F. L., et al. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.11.005 · Cited by 131 · see citing works
Heterogeneous integration of CdS filters with GaN LEDs for fluorescence detection microsystems
Chediak, J. A., Luo, Z., Seo, J., et al. (2003) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2003.10.015 · Cited by 129 · see citing works
Fully integrated whole blood testing by real-time absorption measurement on a centrifugal platform
Steigert, J., Grumann, M., Brenner, T., et al. (2006) · Lab on a Chip · doi:10.1039/b607051p · Cited by 128 · see citing works
Development of a surface plasmon resonance biosensor for the identification of Campylobacter jejuni
Wei, D. M., Oyarzábal, O. A., Huang, T., et al. (2007) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2006.12.002 · Cited by 120 · see citing works
Detection of avian influenza virus using an interferometric biosensor
Xu, J., Suarez, D. L., & Gottfried, D. S. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1525-3 · Cited by 117 · see citing works
Bhattacharyya, A., & Klapperich, C. M. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-9026-2 · Cited by 110 · see citing works
Wang, X., Hofmann, O., Das, R., Barrett, E. M., deMello, A. J., de Mello, J. C., & Bradley, D. D. C. (2006) · Lab on a Chip · doi:10.1039/b611067c · Cited by 103 · see citing works
Self-citationMultiple internal reflection poly(dimethylsiloxane) systems for optical sensing
Llobera, A., Demming, S., Wilke, R., et al. (2007) · Lab on a Chip · doi:10.1039/b704454b · Cited by 100 · see citing works
Hofmann, O., Wang, X., de Mello, J. C., Bradley, D. D. C., & deMello, A. J. (2005) · Lab on a Chip · doi:10.1039/b504551g · Cited by 90 · see citing works
Self-citationMonodomain alignment of thermotropic fluorene copolymers
Grell, M., Redecker, M., Whitehead, K. S., et al. (1999) · Liquid Crystals · doi:10.1080/026782999204084 · Cited by 86 · see citing works
Microfluidic-optical integrated CMOS compatible devices for label-free biochemical sensing
Blanco, F. J., Agirregabiria, M., Berganzo, J., et al. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/018 · Cited by 82 · see citing works
Edel, J. B., Beard, N. P., Hofmann, O., et al. (2004) · Lab on a Chip · doi:10.1039/b313503a · Cited by 73 · see citing works
Self-citationCompact, high performance surface plasmon resonance imaging system
Chinowsky, T. M., Grow, M. S., Johnston, K. S., et al. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.10.030 · Cited by 72 · see citing works
Patterning of organic devices by interlayer lithography
Huang, J., Xia, R., Kim, Y., et al. (2007) · Journal of Materials Chemistry · doi:10.1039/b614171d · Cited by 72 · see citing works
Self-citationWang, X., Amatatongchai, M., Nacapricha, D., et al. (2009) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2009.04.068 · Cited by 68 · see citing works
Two immunoassay formats for fully automated CRP detection in human serum
Albrecht, C., Käppel, N. D., & Gauglitz, G. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2093-x · Cited by 64 · see citing works
Fluorescence spectrometer-on-a-fluidic-chip
Schmidt, O., Baßler, M., Kiesel, P., et al. (2007) · Lab on a Chip · doi:10.1039/b618879f · Cited by 56 · see citing works
Polymer Microfluidic Chips with Integrated Waveguides for Reading Microarrays
Xu, F., Datta, P., Wang, H., et al. (2007) · Analytical Chemistry · doi:10.1021/ac7016597 · Cited by 53 · see citing works
Opto-electronic DNA chip-based integrated card for clinical diagnostics
Marchand, G., Broyer, P., Lanet, V., et al. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9107-x · Cited by 13 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Wearable Organic Optoelectronic Sensors for Medicine
Bansal, A. K., Hou, S., Kulyk, O., Bowman, E. M., & Samuel, I. D. W. (2015) · Advanced Materials · doi:10.1002/adma.201403560 · Cited by 205 · see citing works
The Current State of Optical Sensors in Medical Wearables
Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H. (2022) · Biosensors · doi:10.3390/bios12040217 · Cited by 103 · see citing works
“[36] where they demonstrated a compact, inexpensive, and practical fluorescence detection system for lab-on-a-chip applications, consisting of 501 nm commercially available InGaN LED, an organic or silicon photodiode, absorptive dye-coated color filters, polarizers, and an injected polystyrene microfluidic chip.”
Background
- Authors
- Ryu, G., Huang, J., Hofmann, O., Walshe, C. A., Sze, J. Y. Y., McClean, G. D., Mosley, A., Rattle, S. J., deMello, J. C., deMello, A. J., & Bradley, D. D. C.
- Affiliations
- Imperial College London (GB)
- Corresponding author
- Rattle, Simon J.
- Bradley, Donal D. C.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 9
- Pages
- 1664
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2082891648
- Cited by
- 93
- References
- 30
- Citations by year
- 2025: 6 · 2024: 3 · 2023: 6 · 2022: 9 · 2021: 6 · 2020: 7 · 2019: 6 · 2018: 4 · 2017: 7 · 2016: 4 · 2015: 6 · 2014: 11 · 2013: 6 · 2012: 6
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Rare & Special e-Zone (The Hong Kong University of Science and Technology) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- microfluidics, photodiode detector, polarization, fluorescence immunoassay, myoglobin, CK-MB, cardiac biomarkers, detection limit, human plasma
- MeSH terms
- Fluorescent Antibody Technique, Humans, Myoglobin, Sensitivity and Specificity, Biomarkers, Point-of-Care Systems, Microfluidic Analytical Techniques, Creatine Kinase, MB Form, Lab-On-A-Chip Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review