Cited by 93Microfluidic and Capillary Electrophoresis ApplicationsBiosensors and Analytical DetectionMicrofluidic and Bio-sensing Technologies

Highly sensitive fluorescence detection system for microfluidic lab-on-a-chip

Ryu, Gihan, Huang, Jingsong, Hofmann, Oliver, Walshe, Claire A., Sze, Jasmine Y. Y., McClean, Gareth D., Mosley, Alan, Rattle, Simon J. +3 more·2011·Lab on a Chip

Abstract

We demonstrate a compact, low cost and practical fluorescence detection system for lab-on-a-chip applications. The system comprises a commercially available InGaN light emitting diode (501 nm) as light source, an organic or silicon photodiode detector, absorptive dye coated colour filters and linear and reflective polarisers. An injection moulded polystyrene microfluidic chip is used as the platform for fluorescence immunoassays for cardiac markers myoglobin and CK-MB. The optical limit of detection (LOD) is measured using a TransFluoSphere® suspension at 5.6 × 10(4) beads µl(-1) which can be equated to ∼3 nM fluorescein equivalent concentration. The LOD for the human plasma immunoassays is measured as 1.5 ng ml(-1) for both myoglobin and CK-MB.

Integrity signals

Registry

Crossref · 10.1039/c0lc00586j

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Ryu et al. demonstrated a compact, inexpensive, and practical fluorescence detection system for lab-on-a-chip applications that can detect the cardiac markers myoglobin and CK-MB from human plasma.

    “Interesting and useful is also the research by Ryu et al. [36] where they demonstrated a compact, inexpensive, and practical fluorescence detection system for lab-on-a-chip applications, consisting of 501 nm commercially available InGaN LED, an organic or silicon photodiode, absorptive dye-coated color filters, polarizers, and an injected polystyrene microfluidic chip.”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [36]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Ryu, G., Huang, J., Hofmann, O., Walshe, C. A., Sze, J. Y. Y., McClean, G. D., Mosley, A., Rattle, S. J., deMello, J. C., deMello, A. J., & Bradley, D. D. C.
Affiliations
Imperial College London (GB)
Corresponding author
  • Rattle, Simon J.
  • Bradley, Donal D. C.
Venue
Lab on a Chip
Published
2011
Volume
11
Issue
9
Pages
1664
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2082891648
Cited by
93
References
30
Citations by year
2025: 6 · 2024: 3 · 2023: 6 · 2022: 9 · 2021: 6 · 2020: 7 · 2019: 6 · 2018: 4 · 2017: 7 · 2016: 4 · 2015: 6 · 2014: 11 · 2013: 6 · 2012: 6
FWCI
5.29
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
  • Rare & Special e-Zone (The Hong Kong University of Science and Technology) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
Keywords
microfluidics, photodiode detector, polarization, fluorescence immunoassay, myoglobin, CK-MB, cardiac biomarkers, detection limit, human plasma
MeSH terms
Fluorescent Antibody Technique, Humans, Myoglobin, Sensitivity and Specificity, Biomarkers, Point-of-Care Systems, Microfluidic Analytical Techniques, Creatine Kinase, MB Form, Lab-On-A-Chip Devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review