The DOI matches its Crossref record.
Phaseguides: a paradigm shift in microfluidic priming and emptying
Abstract
Phaseguide technology gives complete control over filling and emptying of any type of microfluidic structures, independent of the chamber and channel geometry. The technique is based on a step-wise advancement of the liquid-air interface using the meniscus pinning effect. In this paper, the main effects and parameters underlying the phaseguiding principle are discussed and a demonstration is given of its potential for dead angle filling, spatially controlled phaseguide overflow and sequential phaseguide overflow, all accumulating in a passive valving approach. Phaseguides represent a new direction in microfluidic design thinking that will prove a leap forward towards more simple, flexible and reliable microfluidic systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Quan, P.-L., Sauzade, M., & Brouzes, E. (2018) · Sensors · doi:10.3390/s18041271 · Cited by 664
Capillary microfluidics in microchannels: from microfluidic networks to capillaric circuits
Olanrewaju, A., Beaugrand, M., Yafia, M., & Juncker, D. (2018) · Lab on a Chip · doi:10.1039/c8lc00458g · Cited by 451
Development of Polymeric Nanoparticles for Blood–Brain Barrier Transfer—Strategies and Challenges
Zhang, W., Mehta, A., Tong, Z., Esser, L., & Voelcker, N. H. (2021) · Advanced Science · doi:10.1002/advs.202003937 · Cited by 430
Reconfigurable microfluidic hanging drop network for multi-tissue interaction and analysis
Frey, O., Misun, P. M., Fluri, D. A., Hengstler, J. G., & Hierlemann, A. (2014) · Nature Communications · doi:10.1038/ncomms5250 · Cited by 387
Białkowska, K., Komorowski, P., Bryszewska, M., & Miłowska, K. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21176225 · Cited by 382
Trietsch, S. J., Naumovska, E., Kurek, D., Setyawati, M. C., Vormann, M. K., Wilschut, K. J., Lanz, H. L., Nicolas, A., Ng, C. P., Joore, J., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00259-3 · Cited by 290
Self-citationMicro Total Analysis Systems for Cell Biology and Biochemical Assays
Kovarik, M. L., Gach, P. C., Ornoff, D. M., Wang, Y., Balowski, J., Farrag, L., & Allbritton, N. L. (2012) · Analytical Chemistry · doi:10.1021/ac202611x · Cited by 270
Isothermal Amplification Methods for the Detection of Nucleic Acids in Microfluidic Devices
Zanoli, L., & Spoto, G. (2012) · Biosensors · doi:10.3390/bios3010018 · Cited by 265
Microfluidic titer plate for stratified 3D cell culture
Trietsch, S. J., Israëls, G. D., Joore, J., Hankemeier, T., & Vulto, P. (2013) · Lab on a Chip · doi:10.1039/c3lc50210d · Cited by 189
Self-citationTherapy response testing of breast cancer in a 3D high-throughput perfused microfluidic platform
Lanz, H. L., Saleh, A., Kramer, B., Cairns, J., Ng, C. P., Yu, J., Trietsch, S. J., Hankemeier, T., Joore, J., Vulto, P., et al. (2017) · BMC Cancer · doi:10.1186/s12885-017-3709-3 · Cited by 135
Self-citationIn vitro grafting of hepatic spheroids and organoids on a microfluidic vascular bed
Bonanini, F., Kurek, D., Previdi, S., Nicolas, A., Hendriks, D., de Ruiter, S., Meyer, M., Clapés Cabrer, M., Dinkelberg, R., García, S. B., et al. (2022) · Angiogenesis · doi:10.1007/s10456-022-09842-9 · Cited by 112
Self-citationMicrofluidic high-throughput 3D cell culture
Ko, J., Park, D., Lee, J., Jung, S., Baek, K., Sung, K. E., Lee, J., & Jeon, N. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00163-8 · Cited by 88
Huang, Y. L., Tung, C.-K., Zheng, A., Kim, B. J., & Wu, M. (2015) · Integrative Biology · doi:10.1039/c5ib00115c · Cited by 75
Multiscale microenvironmental perturbation of pluripotent stem cell fate and self-organization
Tabata, Y., & Lutolf, M. P. (2017) · Scientific Reports · doi:10.1038/srep44711 · Cited by 37
Vormann, M. K., Tool, L. M., Ohbuchi, M., Gijzen, L., van Vught, R., Hankemeier, T., Kiyonaga, F., Kawabe, T., Goto, T., Fujimori, A., et al. (2022) · Kidney360 · doi:10.34067/kid.0003622021 · Cited by 39
Self-citation
Metadata
- Authors
- Vulto, P., Podszun, S., Meyer, P., Hermann, C., Manz, A., & Urban, G. A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 9
- Pages
- 1596
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W1964690307
- Cited by
- 222
- References
- 0
- FWCI
- 5.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.