The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Integration of cell phone imaging with microchip ELISA to detect ovarian cancer HE4 biomarker in urine at the point-of-care
Open accessAbstract
Ovarian cancer is asymptomatic in the early stages and most patients present with advanced levels of disease. The lack of cost-effective methods that can achieve frequent, simple and non-invasive testing hinders early detection and causes high mortality in ovarian cancer patients. Here, we report a simple and inexpensive microchip ELISA-based detection module that employs a portable detection system, i.e., a cell phone/charge-coupled device (CCD) to quantify an ovarian cancer biomarker, HE4, in urine. Integration of a mobile application with a cell phone enabled immediate processing of microchip ELISA results, which eliminated the need for a bulky, expensive spectrophotometer. The HE4 level detected by a cell phone or a lensless CCD system was significantly elevated in urine samples from cancer patients (n = 19) than healthy controls (n = 20) (p < 0.001). Receiver operating characteristic (ROC) analyses showed that the microchip ELISA coupled with a cell phone running an automated analysis mobile application had a sensitivity of 89.5% at a specificity of 90%. Under the same specificity, the microchip ELISA coupled with a CCD had a sensitivity of 84.2%. In conclusion, integration of microchip ELISA with cell phone/CCD-based colorimetric measurement technology can be used to detect HE4 biomarker at the point-of-care (POC), paving the way to create bedside technologies for diagnostics and treatment monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rubin, M., & Stephen, C. D. (1993) · Cited by 3,149
The biology of ovarian cancer: new opportunities for translation
Bast, R. C., Hennessy, B., & Mills, G. B. (2009) · Nature Reviews Cancer · doi:10.1038/nrc2644 · Cited by 1,358
Making it stick: convection, reaction and diffusion in surface-based biosensors
Squires, T. M., Messinger, R. J., & Manalis, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt1388 · Cited by 986
Moore, R. G., McMeekin, D. S., Brown, A. K., DiSilvestro, P., Miller, M. C., Allard, W. J., Gajewski, W., Kurman, R., Bast, R. C., & Skates, S. J. (2009) · Gynecologic Oncology · doi:10.1016/j.ygyno.2008.08.031 · Cited by 875
The HE4 (WFDC2) protein is a biomarker for ovarian carcinoma.
Hellström, I., Raycraft, J., Hayden-Ledbetter, M. S., Ledbetter, J. A., Schummer, M., McIntosh, M. W., Drescher, C. W., Urban, N. D., & Hellström, K. E. (2003) · PubMed · Cited by 711
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Hennessy, B. T., Coleman, R. L., & Markman, M. (2009) · The Lancet · doi:10.1016/s0140-6736(09)61338-6 · Cited by 640
Rapid tests for sexually transmitted infections (STIs): the way forward
Peeling, R. W., Holmes, K. K., Mabey, D., & Ronald, A. (2006) · Sexually Transmitted Infections · doi:10.1136/sti.2006.024265 · Cited by 599
Normalization of urinary biomarkers to creatinine during changes in glomerular filtration rate
Waikar, S. S., Sabbisetti, V. S., & Bonventre, J. V. (2010) · Kidney International · doi:10.1038/ki.2010.165 · Cited by 450
Clarke-Pearson, D. L. (2009) · New England Journal of Medicine · doi:10.1056/nejmcp0901926 · Cited by 400
Cited by
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Self-citationBiosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 647
Point-of-care colorimetric detection with a smartphone
Shen, L., Hagen, J. A., & Papautsky, I. (2012) · Lab on a Chip · doi:10.1039/c2lc40741h · Cited by 609
Lopez-Ruiz, N., Curto, V. F., Erenas, M. M., Benito-Lopez, F., Diamond, D., Palma, A. J., & Capitan-Vallvey, L. F. (2014) · Analytical Chemistry · doi:10.1021/ac5019205 · Cited by 423
Advances in Plasmonic Technologies for Point of Care Applications
Tokel, O., Inci, F., & Demirci, U. (2014) · Chemical Reviews · doi:10.1021/cr4000623 · Cited by 407
Self-citationBerg, B., Cortazar, B., Tseng, D., Ozkan, H., Feng, S., Wei, Q., Chan, R. Y.-L., Burbano, J., Farooqui, Q., Lewinski, M., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b03203 · Cited by 362
Lin, M., Zhao, Y., Wang, S., Liu, M., Duan, Z., Chen, Y., Li, F., Xu, F., & Lu, T. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2012.04.009 · Cited by 325
Self-citationPires, N., Dong, T., Hanke, U., & Hoivik, N. (2014) · Sensors · doi:10.3390/s140815458 · Cited by 307
A smartphone algorithm with inter-phone repeatability for the analysis of colorimetric tests
Yetisen, A. K., Martinez-Hurtado, J. L., Garcia-Melendrez, A., da Cruz Vasconcellos, F., & Lowe, C. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.077 · Cited by 285
Liang, L.-G., Kong, M.-Q., Zhou, S., Sheng, Y.-F., Wang, P., Yu, T., Inci, F., Kuo, W. P., Li, L.-J., Demirci, U., et al. (2017) · Scientific Reports · doi:10.1038/srep46224 · Cited by 282
Self-citationShen, J., Li, Y., Gu, H., Xia, F., & Zuo, X. (2014) · Chemical Reviews · doi:10.1021/cr300248x · Cited by 273
Metadata
- Authors
- Wang, S., Zhao, X., Khimji, I., Akbas, R., Qiu, W., Edwards, D., Cramer, D. W., Ye, B., & Demirci, U.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2011
- Volume
- 11
- Issue
- 20
- Pages
- 3411
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2115585598
- Cited by
- 254
- References
- 26
- FWCI
- 11.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.