Determination of very low amounts of chromium(iii) and (vi) using dispersive liquid–liquid microextraction by in situ formation of an ionic liquid followed by electrothermal atomic absorption spectrometry
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
A new procedure for the determination of very low levels of Cr(III) and Cr(VI) using ionic liquid dispersive liquid–liquid microextraction (IL-DLLME) followed by electrothermal atomic absorption spectrometry (ETAAS) is presented. The ionic liquid, 1-octyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide ([C8MIm][NTf2]), is formed in situ by mixing 1-octyl-3-methylimidazolium chloride ([C8MIm]Cl) and lithium bis(trifluoromethanesulfonyl)imide ([NTf2]Li) aqueous solutions, and is used to extract complexes originating from Cr(III) and Cr(VI) with ammonium pyrrolidinedithiocarbamate (APDC). No organic solvents are required, the dispersion being due to the very fine droplets of ([C8MIm][NTf2]) originated in the aqueous solution. After centrifugation, the concentration of chromium in the sedimented phase is determined by ETAAS. The total content of chromium is measured using 0.01 mol L−1 APDC at pH = 1. In the presence of 0.001 mol L−1 ethylenediaminetetraacetate, Cr(III) is not extracted, and the analytical signal corresponds to Cr(VI). The level of Cr(III) is obtained by difference. The enrichment factor of the procedure is 300 and a detection limit of 2 ng L−1 is achieved. The relative standard deviation for 10 replicates at the 0.05 μg L−1 level is close to 8%. The recoveries of spiked samples are in the 95–104% range. The method is applied to the analysis of water samples as well as lixiviates obtained from toys made of plastic materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Dadfarnia, S., & Haji Shabani, A. M. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2009.11.022 · Cited by 305
Liu, Y., Zhao, E., Zhu, W., Gao, H., & Zhou, Z. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.11.076 · Cited by 301
Zhou, Q., Bai, H., Xie, G., & Xiao, J. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.094 · Cited by 248
Liquid-phase microextraction techniques within the framework of green chemistry
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.016 · Cited by 221
Yao, C., & Anderson, J. L. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3078-0 · Cited by 204
Yao, C., Pitner, W. R., & Anderson, J. L. (2009) · Analytical Chemistry · doi:10.1021/ac900719m · Cited by 167
Separation and Preconcentration by Dispersive Liquid–Liquid Microextraction Procedure: A Review
Bosch Ojeda, C., & Sánchez Rojas, F. (2009) · Chromatographia · doi:10.1365/s10337-009-1104-1 · Cited by 124
A ionic liquid for dispersive liquid-liquid microextraction of phenols
Fan, Y. C., Chen, M. L., Shen-Tu, C., & Zhu, Y. (2009) · Journal of Analytical Chemistry · doi:10.1134/s1061934809100074 · Cited by 43
Cited by
Ionic liquids synthesis and applications: An overview
Singh, S. K., & Savoy, A. W. (2020) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2019.112038 · Cited by 1,233
Ionic Liquids in Analytical Chemistry: Fundamentals, Advances, and Perspectives
Ho, T. D., Zhang, C., Hantao, L. W., & Anderson, J. L. (2014) · Analytical Chemistry · doi:10.1021/ac4035554 · Cited by 487
Green aspects, developments and perspectives of liquid phase microextraction techniques
Spietelun, A., Marcinkowski, Ł., de la Guardia, M., & Namieśnik, J. (2014) · Talanta · doi:10.1016/j.talanta.2013.10.050 · Cited by 333
Recent development and applications of dispersive liquid–liquid microextraction
Yan, H., & Wang, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.04.053 · Cited by 256
Advances in solvent-microextraction techniques
Kokosa, J. M. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2012.09.020 · Cited by 225
Metadata
- Authors
- López-García, I., Vicente-Martínez, Y., & Hernández-Córdoba, M.
- Venue
- Journal of Analytical Atomic Spectrometry
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 27
- Issue
- 5
- Pages
- 874
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2084513189
- Cited by
- 52
- References
- 9
- FWCI
- 7.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.