The DOI matches its Crossref record; 210 of the 210 references it cites were found in a registry or an index.
Design of pressure-driven microfluidic networks using electric circuit analogy
Abstract
This article reviews the application of electric circuit methods for the analysis of pressure-driven microfluidic networks with an emphasis on concentration- and flow-dependent systems. The application of circuit methods to microfluidics is based on the analogous behaviour of hydraulic and electric circuits with correlations of pressure to voltage, volumetric flow rate to current, and hydraulic to electric resistance. Circuit analysis enables rapid predictions of pressure-driven laminar flow in microchannels and is very useful for designing complex microfluidic networks in advance of fabrication. This article provides a comprehensive overview of the physics of pressure-driven laminar flow, the formal analogy between electric and hydraulic circuits, applications of circuit theory to microfluidic network-based devices, recent development and applications of concentration- and flow-dependent microfluidic networks, and promising future applications. The lab-on-a-chip (LOC) and microfluidics community will gain insightful ideas and practical design strategies for developing unique microfluidic network-based devices to address a broad range of biological, chemical, pharmaceutical, and other scientific and technical challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Laser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Active and passive micromixers: A comprehensive review
Bayareh, M., Ashani, M. N., & Usefian, A. (2020) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2019.107771 · Cited by 500
Electronics-free pneumatic circuits for controlling soft-legged robots
Drotman, D., Jadhav, S., Sharp, D., Chan, C., & Tolley, M. T. (2021) · Science Robotics · doi:10.1126/scirobotics.aay2627 · Cited by 430
3D printing: an emerging tool for novel microfluidics and lab-on-a-chip applications
Yazdi, A. A., Popma, A., Wong, W., Nguyen, T., Pan, Y., & Xu, J. (2016) · Microfluidics and Nanofluidics · doi:10.1007/s10404-016-1715-4 · Cited by 307
Discrete elements for 3D microfluidics
Bhargava, K. C., Thompson, B., & Malmstadt, N. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1414764111 · Cited by 298
Moshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
Concentration gradient generation methods based on microfluidic systems
Wang, X., Liu, Z., & Pang, Y. (2017) · RSC Advances · doi:10.1039/c7ra04494a · Cited by 219
Lee, H.-B., Meeseepong, M., Trung, T. Q., Kim, B.-Y., & Lee, N.-E. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112133 · Cited by 153
Lee, J. B., & Sung, J. H. (2013) · Biotechnology Journal · doi:10.1002/biot.201300086 · Cited by 92
Metadata
- Authors
- Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 3
- Pages
- 515-545
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2140974583
- Cited by
- 685
- References
- 210
- FWCI
- 12.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.