The DOI matches its Crossref record; 210 of the 210 references it cites were found in a registry or an index.
Design of pressure-driven microfluidic networks using electric circuit analogy
Abstract
This article reviews the application of electric circuit methods for the analysis of pressure-driven microfluidic networks with an emphasis on concentration- and flow-dependent systems. The application of circuit methods to microfluidics is based on the analogous behaviour of hydraulic and electric circuits with correlations of pressure to voltage, volumetric flow rate to current, and hydraulic to electric resistance. Circuit analysis enables rapid predictions of pressure-driven laminar flow in microchannels and is very useful for designing complex microfluidic networks in advance of fabrication. This article provides a comprehensive overview of the physics of pressure-driven laminar flow, the formal analogy between electric and hydraulic circuits, applications of circuit theory to microfluidic network-based devices, recent development and applications of concentration- and flow-dependent microfluidic networks, and promising future applications. The lab-on-a-chip (LOC) and microfluidics community will gain insightful ideas and practical design strategies for developing unique microfluidic network-based devices to address a broad range of biological, chemical, pharmaceutical, and other scientific and technical challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Laser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Di Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Massively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
Micromachined Transducers Sourcebook
Kovacs, G. T. A. (1998) · Cited by 1,200
Becker, H. (2002) · Talanta · doi:10.1016/s0039-9140(01)00594-x · Cited by 1,187
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Digital microfluidics: is a true lab-on-a-chip possible?
Fair, R. B. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0161-8 · Cited by 1,063
(1978) · Cited by 1,056
Controlled microfluidic interfaces
Atencia, J., & Beebe, D. J. (2005) · Nature · doi:10.1038/nature04163 · Cited by 1,006
Micro Total Analysis Systems. Recent Developments
Vilkner, T., Janasek, D., & Manz, A. (2004) · Analytical Chemistry · doi:10.1021/ac040063q · Cited by 968
Generation of Solution and Surface Gradients Using Microfluidic Systems
Jeon, N. L., Dertinger, S. K. W., Chiu, D. T., Choi, I. S., Stroock, A. D., & Whitesides, G. M. (2000) · Langmuir · doi:10.1021/la000600b · Cited by 963
Micro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Synergistic drug combinations tend to improve therapeutically relevant selectivity
Lehár, J., Krueger, A. S., Avery, W., Heilbut, A. M., Johansen, L. M., Price, E. R., Rickles, R. J., Short III, G. F., Staunton, J. E., Jin, X., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1549 · Cited by 938
Hydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887
Polymer microstructures formed by moulding in capillaries
Kim, E., Xia, Y., & Whitesides, G. M. (1995) · Nature · doi:10.1038/376581a0 · Cited by 878
Generation of Gradients Having Complex Shapes Using Microfluidic Networks
Dertinger, S. K. W., Chiu, D. T., Jeon, N. L., & Whitesides, G. M. (2001) · Analytical Chemistry · doi:10.1021/ac001132d · Cited by 839
Oh, K. W., & Ahn, C. H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/r01 · Cited by 838
Self-citationAn extracellular matrix microarray for probing cellular differentiation
Flaim, C. J., Chien, S., & Bhatia, S. N. (2005) · Nature Methods · doi:10.1038/nmeth736 · Cited by 803
Polymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795
Micro- and Nanoscale Fluid Mechanics: Transport in Microfluidic Devices
Kirby, B. J. (2010) · Cited by 753
Yamada, M., Nakashima, M., & Seki, M. (2004) · Analytical Chemistry · doi:10.1021/ac049863r · Cited by 746
Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
Melin, J., & Quake, S. R. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132646 · Cited by 738
Centrifugal microfluidics for biomedical applications
Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K. (2010) · Lab on a Chip · doi:10.1039/b924109d · Cited by 731
Inertial microfluidics for continuous particle separation in spiral microchannels
Kuntaegowdanahalli, S. S., Bhagat, A. A. S., Kumar, G., & Papautsky, I. (2009) · Lab on a Chip · doi:10.1039/b908271a · Cited by 708
Dynamic single cell culture array
Carlo, D. D., Wu, L. Y., & Lee, L. P. (2006) · Lab on a Chip · doi:10.1039/b605937f · Cited by 707
Siloxane Polymers for High-Resolution, High-Accuracy Soft Lithography
Schmid, H., & Michel, B. (2000) · Macromolecules · doi:10.1021/ma982034l · Cited by 673
Continuous particle separation in spiral microchannels using dean flows and differential migration
Bhagat, A. A. S., Kuntaegowdanahalli, S. S., & Papautsky, I. (2008) · Lab on a Chip · doi:10.1039/b807107a · Cited by 656
Components for integrated poly(dimethylsiloxane) microfluidic systems
Ng, J. M. K., Gitlin, I., Stroock, A. D., & Whitesides, G. M. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200210)23:20<3461::aid-elps3461>3.0.co;2-8 · Cited by 626
Versatile, Fully Automated, Microfluidic Cell Culture System
Gómez-Sjöberg, R., Leyrat, A. A., Pirone, D. M., Chen, C. S., & Quake, S. R. (2007) · Analytical Chemistry · doi:10.1021/ac071311w · Cited by 625
Flexible Methods for Microfluidics
Whitesides, G. M., & Stroock, A. D. (2001) · Physics Today · doi:10.1063/1.1387591 · Cited by 595
A trap-and-release integrated microfluidic system for dynamic microarray applications
Tan, W.-H., & Takeuchi, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606625104 · Cited by 591
Microfluidic control of cell pairing and fusion
Skelley, A. M., Kirak, O., Suh, H., Jaenisch, R., & Voldman, J. (2009) · Nature Methods · doi:10.1038/nmeth.1290 · Cited by 571
Human neural stem cell growth and differentiation in a gradient-generating microfluidic device
Chung, B. G., Flanagan, L. A., Rhee, S. W., Schwartz, P. H., Lee, A. P., Monuki, E. S., & Jeon, N. L. (2005) · Lab on a Chip · doi:10.1039/b417651k · Cited by 556
Fan, R., Vermesh, O., Srivastava, A., Yen, B. K. H., Qin, L., Ahmad, H., Kwong, G. A., Liu, C.-C., Gould, J., Hood, L., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt.1507 · Cited by 539
Microfluidic fuel cell based on laminar flow
Choban, E. (2004) · Journal of Power Sources · doi:10.1016/j.jpowsour.2003.11.052 · Cited by 534
Continuous perfusion microfluidic cell culture array for high‐throughput cell‐based assays
Hung, P. J., Lee, P. J., Sabounchi, P., Lin, R., & Lee, L. P. (2005) · Biotechnology and Bioengineering · doi:10.1002/bit.20289 · Cited by 522
Prakash, M., & Gershenfeld, N. (2007) · Science · doi:10.1126/science.1136907 · Cited by 511
Disposable Smart Lab on a Chip for Point-of-Care Clinical Diagnostics
Ahn, C. H., Choi, J.-W., Beaucage, G., Nevin, J., Lee, J.-B., Puntambekar, A., & Lee, R. J. Y. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820548 · Cited by 504
Micro- and Nanoscale Fluid Mechanics: Transport in Microfluidic Devices
Kirby, B. J. (2012) · Cambridge University Press eBooks · doi:10.1017/cbo9780511760723 · Cited by 486
Controlled Synthesis of Nonspherical Microparticles Using Microfluidics
Dendukuri, D., Tsoi, K., Hatton, T. A., & Doyle, P. S. (2005) · Langmuir · doi:10.1021/la047368k · Cited by 482
Di Carlo, D., Aghdam, N., & Lee, L. P. (2006) · Analytical Chemistry · doi:10.1021/ac060541s · Cited by 458
A practical guide to microfluidic perfusion culture of adherent mammalian cells
Kim, L., Toh, Y.-C., Voldman, J., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b704602b · Cited by 455
Gradients of substrate-bound laminin orient axonal specification of neurons
Dertinger, S. K. W., Jiang, X., Li, Z., Murthy, V. N., & Whitesides, G. M. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.192457199 · Cited by 446
Fabrication of microfluidic devices using polydimethylsiloxane
Friend, J., & Yeo, L. (2010) · Biomicrofluidics · doi:10.1063/1.3259624 · Cited by 425
Micro Total Analysis Systems: Latest Achievements
West, J., Becker, M., Tombrink, S., & Manz, A. (2008) · Analytical Chemistry · doi:10.1021/ac800680j · Cited by 423
Critical particle size for fractionation by deterministic lateral displacement
Inglis, D. W., Davis, J. A., Austin, R. H., & Sturm, J. C. (2006) · Lab on a Chip · doi:10.1039/b515371a · Cited by 421
Latest Developments in Micro Total Analysis Systems
Arora, A., Simone, G., Salieb-Beugelaar, G. B., Kim, J. T., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac100969k · Cited by 421
Microengineered Platforms for Cell Mechanobiology
Kim, D.-H., Wong, P. K., Park, J., Levchenko, A., & Sun, Y. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124915 · Cited by 411
Microfluidic Shear Devices for Quantitative Analysis of Cell Adhesion
Lu, H., Koo, L. Y., Wang, W. M., Lauffenburger, D. A., Griffith, L. G., & Jensen, K. F. (2004) · Analytical Chemistry · doi:10.1021/ac049837t · Cited by 405
Computerized microfluidic cell culture using elastomeric channels and Braille displays
Gu, W., Zhu, X., Futai, N., Cho, B. S., & Takayama, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404353101 · Cited by 403
Combinatorial and High‐Throughput Materials Science
Maier, W. F., Stöwe, K., & Sieg, S. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603675 · Cited by 401
Fundamentals of Fluid Mechanics
Rubenstein, D. A., Yin, W., & Frame, M. D. (2012) · Biofluid Mechanics · doi:10.1016/b978-0-12-381383-1.00002-3 · Cited by 397
A rapid diffusion immunoassay in a T-sensor
Hatch, A., Kamholz, A. E., Hawkins, K. R., Munson, M. S., Schilling, E. A., Weigl, B. H., & Yager, P. (2001) · Nature Biotechnology · doi:10.1038/88135 · Cited by 383
Re-configurable fluid circuits by PDMS elastomer micromachining
Armani, D., Liu, C., & Aluru, N. (1999) · Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291) · doi:10.1109/memsys.1999.746817 · Cited by 382
The pressure drop along rectangular microchannels containing bubbles
Fuerstman, M. J., Lai, A., Thurlow, M. E., Shevkoplyas, S. S., Stone, H. A., & Whitesides, G. M. (2007) · Lab on a Chip · doi:10.1039/b706549c · Cited by 377
Biological applications of microfluidic gradient devices
Kim, S., Kim, H. J., & Jeon, N. L. (2010) · Integrative Biology · doi:10.1039/c0ib00055h · Cited by 366
Differentiation-on-a-chip: A microfluidic platform for long-term cell culture studies
Tourovskaia, A., Figueroa-Masot, X., & Folch, A. (2005) · Lab on a Chip · doi:10.1039/b405719h · Cited by 363
Xurography: rapid prototyping of microstructures using a cutting plotter
Bartholomeusz, D. A., Boutte, R. W., & Andrade, J. D. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859087 · Cited by 360
Flow-induced deformation of shallow microfluidic channels
Gervais, T., El-Ali, J., Günther, A., & Jensen, K. F. (2006) · Lab on a Chip · doi:10.1039/b513524a · Cited by 359
Microfabricated elastomeric stencils for micropatterning cell cultures
Folch, A., Jo, B.-H., Hurtado, O., Beebe, D. J., & Toner, M. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200011)52:2<346::aid-jbm14>3.0.co;2-h · Cited by 354
Singh, B., Kumar, R., & Ahuja, N. (2005) · Critical Reviews in Therapeutic Drug Carrier Systems · doi:10.1615/critrevtherdrugcarriersyst.v22.i1.20 · Cited by 352
Huebner, A., Bratton, D., Whyte, G., Yang, M., deMello, A. J., Abell, C., & Hollfelder, F. (2009) · Lab Chip · doi:10.1039/b813709a · Cited by 346
Gervais, L., & Delamarche, E. (2009) · Lab on a Chip · doi:10.1039/b906523g · Cited by 345
A sensitive, versatile microfluidic assay for bacterial chemotaxis
Mao, H., Cremer, P. S., & Manson, M. D. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0931258100 · Cited by 332
Gravity-Driven Microfluidic Particle Sorting Device with Hydrodynamic Separation Amplification
Huh, D., Bahng, J. H., Ling, Y., Wei, H.-H., Kripfgans, O. D., Fowlkes, J. B., Grotberg, J. B., & Takayama, S. (2007) · Analytical Chemistry · doi:10.1021/ac061542n · Cited by 315
Mortensen, N. A., Okkels, F., & Bruus, H. (2005) · Physical Review E · doi:10.1103/physreve.71.057301 · Cited by 305
Dynamic control of liquid-core/liquid-cladding optical waveguides
Wolfe, D. B., Conroy, R. S., Garstecki, P., Mayers, B. T., Fischbach, M. A., Paul, K. E., Prentiss, M., & Whitesides, G. M. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404423101 · Cited by 301
Schilling, E. A., Kamholz, A. E., & Yager, P. (2002) · Analytical Chemistry · doi:10.1021/ac015640e · Cited by 299
Integrated Cell Isolation and Polymerase Chain Reaction Analysis Using Silicon Microfilter Chambers
Wilding, P., Kricka, L. J., Cheng, J., Hvichia, G., Shoffner, M. A., & Fortina, P. (1998) · Analytical Biochemistry · doi:10.1006/abio.1997.2530 · Cited by 276
Microfluidics in Biotechnology
(2022) · Advances in Biochemical Engineering/Biotechnology · doi:10.1007/978-3-031-04188-4 · Cited by 266
Effects of flow and diffusion on chemotaxis studies in a microfabricated gradient generator
Walker, G. M., Sai, J., Richmond, A., Stremler, M., Chung, C. Y., & Wikswo, J. P. (2005) · Lab on a Chip · doi:10.1039/b417245k · Cited by 266
Microfluidic arrays for logarithmically perfused embryonic stem cell culture
Kim, L., Vahey, M. D., Lee, H.-Y., & Voldman, J. (2006) · Lab on a Chip · doi:10.1039/b511718f · Cited by 262
Hosokawa, K., Sato, K., Ichikawa, N., & Maeda, M. (2004) · Lab on a Chip · doi:10.1039/b403930k · Cited by 260
Hung, P. J., Lee, P. J., Sabounchi, P., Aghdam, N., Lin, R., & Lee, L. P. (2005) · Lab on a Chip · doi:10.1039/b410743h · Cited by 259
Lab-on-a-Foil: microfluidics on thin and flexible films
Focke, M., Kosse, D., Müller, C., Reinecke, H., Zengerle, R., & von Stetten, F. (2010) · Lab on a Chip · doi:10.1039/c001195a · Cited by 255
Cell-based high content screening using an integrated microfluidic device
Ye, N., Qin, J., Shi, W., Liu, X., & Lin, B. (2007) · Lab on a Chip · doi:10.1039/b711513j · Cited by 246
Microfluidic Devices for Electrokinetically Driven Parallel and Serial Mixing
Jacobson, S. C., McKnight, T. E., & Ramsey, J. M. (1999) · Analytical Chemistry · doi:10.1021/ac990576a · Cited by 233
Universal Microfluidic Gradient Generator
Irimia, D., Geba, D. A., & Toner, M. (2006) · Analytical Chemistry · doi:10.1021/ac0518710 · Cited by 233
Biomimetic Autoseparation of Leukocytes from Whole Blood in a Microfluidic Device
Shevkoplyas, S. S., Yoshida, T., Munn, L. L., & Bitensky, M. W. (2005) · Analytical Chemistry · doi:10.1021/ac049037i · Cited by 225
Macro-to-micro interfaces for microfluidic devices
Fredrickson, C. K., & Fan, Z. H. (2004) · Lab on a Chip · doi:10.1039/b410720a · Cited by 225
Phaseguides: a paradigm shift in microfluidic priming and emptying
Vulto, P., Podszun, S., Meyer, P., Hermann, C., Manz, A., & Urban, G. A. (2011) · Lab on a Chip · doi:10.1039/c0lc00643b · Cited by 222
Generation of dynamic temporal and spatial concentration gradients using microfluidic devices
Lin, F., Saadi, W., Rhee, S. W., Wang, S.-J., Mittal, S., & Jeon, N. L. (2004) · Lab on a Chip · doi:10.1039/b313600k · Cited by 222
Permeation-driven flow in poly(dimethylsiloxane) microfluidic devices.
Randall, G. C., & Doyle, P. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503287102 · Cited by 220
A microfabricated array of clamps for immobilizing and imaging C. elegans
Hulme, S. E., Shevkoplyas, S. S., Apfeld, J., Fontana, W., & Whitesides, G. M. (2007) · Lab on a Chip · doi:10.1039/b707861g · Cited by 216
Macro- and microscale fluid flow systems for endothelial cell biology
Young, E. W. K., & Simmons, C. A. (2010) · Lab Chip · doi:10.1039/b913390a · Cited by 215
Frequency-specific flow control in microfluidic circuits with passive elastomeric features
Leslie, D. C., Easley, C. J., Şeker, E., Karlinsey, J. M., Utz, M., Begley, M. R., & Landers, J. P. (2009) · Nature Physics · doi:10.1038/nphys1196 · Cited by 213
Latest Developments in Microfluidic Cell Biology and Analysis Systems
Salieb-Beugelaar, G. B., Simone, G., Arora, A., Philippi, A., & Manz, A. (2010) · Analytical Chemistry · doi:10.1021/ac1009707 · Cited by 207
A parallel-gradient microfluidic chamber for quantitative analysis of breast cancer cell chemotaxis
Saadi, W., Wang, S.-J., Lin, F., & Jeon, N. L. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-7706-6 · Cited by 204
Yu, C., Mutlu, S., Selvaganapathy, P., Mastrangelo, C. H., Svec, F., & Fréchet, J. M. J. (2003) · Analytical Chemistry · doi:10.1021/ac026455j · Cited by 202
Optimization of microfluidic single cell trapping for long-term on-chip culture
Kobel, S., Valero, A., Latt, J., Renaud, P., & Lutolf, M. (2010) · Lab on a Chip · doi:10.1039/b918055a · Cited by 195
Microfluidic Particle Sorter Employing Flow Splitting and Recombining
Yamada, M., & Seki, M. (2006) · Analytical Chemistry · doi:10.1021/ac0520083 · Cited by 177
Nakajima, M., Ishimuro, T., Kato, K., Ko, I.-K., Hirata, I., Arima, Y., & Iwata, H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.10.004 · Cited by 169
In vitro analysis of a hepatic device with intrinsic microvascular-based channels
Carraro, A., Hsu, W.-M., Kulig, K. M., Cheung, W. S., Miller, M. L., Weinberg, E. J., Swart, E. F., Kaazempur-Mofrad, M., Borenstein, J. T., Vacanti, J. P., et al. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9194-3 · Cited by 168
Dynamic Gene Expression Profiling Using a Microfabricated Living Cell Array
Thompson, D. M., King, K. R., Wieder, K. J., Toner, M., Yarmush, M. L., & Jayaraman, A. (2004) · Analytical Chemistry · doi:10.1021/ac0354241 · Cited by 168
Biomimetic design of microfluidic manifolds based on a generalised Murray's law
Emerson, D. R., Cieślicki, K., Gu, X., & Barber, R. W. (2006) · Lab on a Chip · doi:10.1039/b516975e · Cited by 166
Dynamically reconfigurable liquid-core liquid-cladding lens in a microfluidic channel
Tang, S. K. Y., Stan, C. A., & Whitesides, G. M. (2008) · Lab on a Chip · doi:10.1039/b717037h · Cited by 164
Improved performance of deterministic lateral displacement arrays with triangular posts
Loutherback, K., Chou, K. S., Newman, J., Puchalla, J., Austin, R. H., & Sturm, J. C. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0635-y · Cited by 162
Identification of combinatorial drug regimens for treatment of Huntington's disease using Drosophila
Agrawal, N., Pallos, J., Slepko, N., Apostol, B. L., Bodai, L., Chang, L.-W., Chiang, A.-S., Thompson, L. M., & Marsh, J. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0500055102 · Cited by 162
Generating fixed concentration arrays in a microfluidic device
Holden, M. A., Kumar, S., Castellana, E. T., Beskok, A., & Cremer, P. S. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00129-1 · Cited by 161
A Miniaturized, Parallel, Serially Diluted Immunoassay for Analyzing Multiple Antigens
Jiang, X., Ng, J. M. K., Stroock, A. D., Dertinger, S. K. W., & Whitesides, G. M. (2003) · Journal of the American Chemical Society · doi:10.1021/ja034566+ · Cited by 160
Matrix-dependent adhesion of vascular and valvular endothelial cells in microfluidic channels
Young, E. W. K., Wheeler, A. R., & Simmons, C. A. (2007) · Lab on a Chip · doi:10.1039/b712486d · Cited by 159
Thermal Issues in Next-Generation Integrated Circuits
Gurrum, S. P., Suman, S. K., Joshi, Y. K., & Fedorov, A. G. (2004) · IEEE Transactions on Device and Materials Reliability · doi:10.1109/tdmr.2004.840160 · Cited by 157
Combinatorial mixing of microfluidic streams
NEILS, C. M., Tyree, Z., Finlayson, B. A., & Folch, A. (2004) · Lab on a Chip · doi:10.1039/b314962e · Cited by 154
A General Method for Patterning Gradients of Biomolecules on Surfaces Using Microfluidic Networks
Jiang, X., Xu, Q., Dertinger, S. K. W., Stroock, A. D., Fu, T., & Whitesides, G. M. (2005) · Analytical Chemistry · doi:10.1021/ac048440m · Cited by 154
Application of statistical ‘design of experiments’ methods in drug discovery
Tye, H. (2004) · Drug Discovery Today · doi:10.1016/s1359-6446(04)03086-7 · Cited by 154
Microfluidic devices for studies of shear-dependent platelet adhesion
Gutierrez, E., Petrich, B. G., Shattil, S. J., Ginsberg, M. H., Groisman, A., & Kasirer‐Friede, A. (2008) · Lab on a Chip · doi:10.1039/b804795b · Cited by 148
Generalized serial dilution module for monotonic and arbitrary microfluidic gradient generators
Lee, K., Kim, C., Ahn, B., Panchapakesan, R., Full, A. R., Nordee, L., Kang, J. Y., & Oh, K. W. (2008) · Lab on a Chip · doi:10.1039/b813582g · Cited by 147
Self-citationA double droplet trap system for studying mass transport across a droplet-droplet interface
Bai, Y., He, X., Liu, D., Patil, S. N., Bratton, D., Huebner, A., Hollfelder, F., Abell, C., & Huck, W. T. S. (2010) · Lab on a Chip · doi:10.1039/b925133b · Cited by 146
Simple, robust storage of drops and fluids in a microfluidic device
Boukellal, H., Selimović, Š., Jia, Y., Cristobal, G., & Fraden, S. (2008) · Lab on a Chip · doi:10.1039/b808579j · Cited by 144
Wang, C. J., Li, X., Lin, B., Shim, S., Ming, G., & Levchenko, A. (2008) · Lab on a Chip · doi:10.1039/b713945d · Cited by 140
A Method for Filling Complex Polymeric Microfluidic Devices and Arrays
Monahan, J., Gewirth, A. A., & Nuzzo, R. G. (2001) · Analytical Chemistry · doi:10.1021/ac001426z · Cited by 138
Polinkovsky, M. E., Gutierrez, E., Levchenko, A., & Groisman, A. (2009) · Lab on a Chip · doi:10.1039/b816191g · Cited by 137
Microfluidics analysis of red blood cell membrane viscoelasticity
Tomaiuolo, G., Barra, M., Preziosi, V., Cassinese, A., Rotoli, B., & Guido, S. (2010) · Lab on a Chip · doi:10.1039/c0lc00348d · Cited by 135
Microfluidic Gradient-Generating Device for Pharmacological Profiling
Pihl, J., Sinclair, J., Sahlin, E., Karlsson, M., Petterson, F., Olofsson, J., & Orwar, O. (2005) · Analytical Chemistry · doi:10.1021/ac050218+ · Cited by 135
Cooksey, G. A., Sip, C. G., & Folch, A. (2008) · Lab on a Chip · doi:10.1039/b806803h · Cited by 131
Cell Migration and Polarity on Microfabricated Gradients of Extracellular Matrix Proteins
Gunawan, R. C., Silvestre, J., Gaskins, H. R., Kenis, P. J. A., & Leckband, D. E. (2006) · Langmuir · doi:10.1021/la0531493 · Cited by 128
Microfluidic devices for size-dependent separation of liver cells
Yamada, M., Kano, K., Tsuda, Y., Kobayashi, J., Yamato, M., Seki, M., & Okano, T. (2007) · Biomedical Microdevices · doi:10.1007/s10544-007-9055-5 · Cited by 125
Direct-write assembly of biomimetic microvascular networks for efficient fluid transport
Wu, W., Hansen, C. J., Aragón, A. M., Geubelle, P. H., White, S. R., & Lewis, J. A. (2009) · Soft Matter · doi:10.1039/b918436h · Cited by 123
Borenstein, J. T., Tupper, M. M., Mack, P. J., Weinberg, E. J., Khalil, A. S., Hsiao, J. C., & García‐Cardeña, G. (2009) · Biomedical Microdevices · doi:10.1007/s10544-009-9361-1 · Cited by 122
Passive microfluidic pumping using coupled capillary/evaporation effects
Lynn, N. S., Jr., & Dandy, D. S. (2009) · Lab on a Chip · doi:10.1039/b912213c · Cited by 121
Kim, C., Lee, K., Kim, J., Shin, K. S., Lee, K., Kim, T. S., & Kang, J. Y. (2008) · Lab on a Chip · doi:10.1039/b714536e · Cited by 119
Self-citationOn-Chip Immunoassay Using Surface-Enhanced Raman Scattering of Hollow Gold Nanospheres
Chon, H., Lim, C., Ha, S.-M., Ahn, Y., Lee, E. K., Chang, S., Seong, G. H., & Choo, J. (2010) · Analytical Chemistry · doi:10.1021/ac100736t · Cited by 118
Optimal design of microfluidic networks using biologically inspired principles
Barber, R. W., & Emerson, D. R. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0163-6 · Cited by 116
Zhu, X. A., Chu, L. Y., Chueh, B.-H., Shen, M., Hazarika, B., Phadke, N., & Takayama, S. (2004) · The Analyst · doi:10.1039/b407623k · Cited by 113
Morton, K. J., Loutherback, K., Inglis, D. W., Tsui, O. K. C., Sturm, J. C., Chou, S. Y., & Austin, R. H. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0712398105 · Cited by 113
Bound attractant at the leading vs. the trailing edge determines chemotactic prowess
Herzmark, P., Campbell, K., Wang, F., Wong, K., El‐Samad, H., Groisman, A., & Bourne, H. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0705889104 · Cited by 107
Lam, R. H. W., Kim, M., & Thorsen, T. (2009) · Analytical Chemistry · doi:10.1021/ac9006864 · Cited by 104
Droplet motion in microfluidic networks: Hydrodynamic interactions and pressure-drop measurements
Sessoms, D. A., Belloul, M., Engl, W., Roché, M., Courbin, L., & Panizza, P. (2009) · Physical Review E · doi:10.1103/physreve.80.016317 · Cited by 100
Integrated systems for rapid point of care (PoC) blood cell analysis
van Berkel, C., Gwyer, J. D., Deane, S. C., Green, N. G., Holloway, J. A., Hollis, V., & Morgan, H. (2011) · Lab on a Chip · doi:10.1039/c0lc00587h · Cited by 99
Campbell, K., & Groisman, A. (2006) · Lab on a Chip · doi:10.1039/b610011b · Cited by 98
Analysis of pressure-driven air bubble elimination in a microfluidic device
Kang, J. H., Kim, Y. C., & Park, J. (2007) · Lab on a Chip · doi:10.1039/b712672g · Cited by 96
Hydrodynamic focusing for vacuum-pumped microfluidics
Stiles, T., Fallon, R., Vestad, T. A., Oakey, J. S., Marr, D. W. M., Squier, J. A., & Jimenez, R. (2005) · Microfluidics and Nanofluidics · doi:10.1007/s10404-005-0033-z · Cited by 96
A linear dilution microfluidic device for cytotoxicity assays
Walker, G. M., Monteiro‐Riviere, N. A., Rouse, J. G., et al. (2006) · Lab on a Chip · doi:10.1039/b608990a · Cited by 96
Role of high-throughput characterization tools in combinatorial materials science
Potyrailo, R. A., & Takeuchi, I. (2004) · Measurement Science and Technology · doi:10.1088/0957-0233/16/1/001 · Cited by 91
Deterministic Lateral Displacement as a Means to Enrich Large Cells for Tissue Engineering
Green, J. V., Radisic, M., & Murthy, S. K. (2009) · Analytical Chemistry · doi:10.1021/ac9018395 · Cited by 91
An easy to assemble microfluidic perfusion device with a magnetic clamp
Tkachenko, E., Gutierrez, E., Ginsberg, M. H., & Groisman, A. (2009) · Lab on a Chip · doi:10.1039/b812184b · Cited by 89
Hoganson, D. M., Pryor, H. I., Bassett, E. K., Spool, I. D., & Vacanti, J. P. (2010) · Lab on a Chip · doi:10.1039/c0lc00158a · Cited by 88
Solving Mazes Using Microfluidic Networks
Fuerstman, M. J., Deschatelets, P., Kane, R. S., Schwartz, A., Kenis, P. J. A., Deutch, J. M., & Whitesides, G. M. (2003) · Langmuir · doi:10.1021/la030054x · Cited by 87
Pressure‐driven perfusion culture microchamber array for a parallel drug cytotoxicity assay
Sugiura, S., Edahiro, J., Kikuchi, K., Sumaru, K., & Kanamori, T. (2008) · Biotechnology and Bioengineering · doi:10.1002/bit.21836 · Cited by 86
3-Dimensional cell culture for on-chip differentiation of stem cells in embryoid body
Kim, C., Lee, K. S., Bang, J. H., Kim, Y. E., Kim, M., Oh, K. W., Lee, S. H., & Kang, J. Y. (2011) · Lab on a Chip · doi:10.1039/c0lc00516a · Cited by 84
Self-citationEvaporation driven pumping for chromatography application
Goedecke, N., Eijkel, J. C. T., & Manz, A. (2002) · Lab on a Chip · doi:10.1039/b208031c · Cited by 83
Modular microfluidics for gradient generation
Sun, K., Wang, Z., & Jiang, X. (2008) · Lab on a Chip · doi:10.1039/b806140h · Cited by 83
Using three-dimensional microfluidic networks for solving computationally hard problems
Chiu, D. T., Pezzoli, E., Wu, H., Stroock, A. D., & Whitesides, G. M. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.061014198 · Cited by 81
Cell infection within a microfluidic device using virus gradients
Walker, G. M. (2003) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.10.014 · Cited by 80
Microfluidic flow-encoded switching for parallel control of dynamic cellular microenvironments
King, K. R., Wang, S., Jayaraman, A., Yarmush, M. L., & Toner, M. (2007) · Lab on a Chip · doi:10.1039/b716962k · Cited by 79
Microfluidics for reconfigurable electromagnetic metamaterials
Kasırga, T. S., Ertaş, Y. N., & Bayındır, M. (2009) · Applied Physics Letters · doi:10.1063/1.3268448 · Cited by 79
A PDMS viscometer for microliter Newtonian fluid
Han, Z., Tang, X., & Zheng, B. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/9/011 · Cited by 79
Self-powered microfluidic chips for multiplexed protein assays from whole blood
Qin, L., Vermesh, O., Shi, Q., & Heath, J. R. (2009) · Lab on a Chip · doi:10.1039/b821247c · Cited by 79
Sugiura, S., Hattori, K., & Kanamori, T. (2010) · Analytical Chemistry · doi:10.1021/ac1017666 · Cited by 78
A multishear microfluidic device for quantitative analysis of calcium dynamics in osteoblasts
Kou, S., Pan, L., van Noort, D., Meng, G., Wu, X., Sun, H., Xu, J., & Lee, I. (2011) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2011.04.044 · Cited by 73
Islam, R. S., Tisi, D., Levy, M. S., & Lye, G. J. (2007) · Biotechnology Progress · doi:10.1002/bp070059a · Cited by 71
Behavior of a train of droplets in a fluidic network with hydrodynamic traps
Bithi, S. S., & Vanapalli, S. A. (2010) · Biomicrofluidics · doi:10.1063/1.3523053 · Cited by 70
Combinatorial Extracellular Matrices for Human Embryonic Stem Cell Differentiation in 3D
Yang, F., Cho, S., Son, S. M., Hudson, S. P., Bogatyrev, S. R., Keung, L., Kohane, D. S., Langer, R., & Anderson, D. G. (2010) · Biomacromolecules · doi:10.1021/bm100357t · Cited by 69
Simultaneous measurement of reactions in microdroplets filled by concentration gradients
Damean, N. A., Olguín, L. F., Hollfelder, F., Abell, C., & Huck, W. T. S. (2009) · Lab on a Chip · doi:10.1039/b821021g · Cited by 69
Combinatorial and High‐Throughput Methods in Macromolecular Materials Research and Development
Webster, D. C. (2008) · Macromolecular Chemistry and Physics · doi:10.1002/macp.200700558 · Cited by 67
Systematic characterization of degas-driven flow for poly(dimethylsiloxane) microfluidic devices
Liang, D. Y., Tentori, A. M., Dimov, I. K., & Lee, L. P. (2011) · Biomicrofluidics · doi:10.1063/1.3584003 · Cited by 66
A dynamic microarray device for paired bead-based analysis
Teshima, T., Ishihara, H., Iwai, K., Adachi, A., & Takeuchi, S. (2010) · Lab on a Chip · doi:10.1039/c004986g · Cited by 64
A method for reducing pressure-induced deformation in silicone microfluidics
Inglis, D. W. (2010) · Biomicrofluidics · doi:10.1063/1.3431715 · Cited by 63
Glawdel, T., Elbüken, Ç., Lee, L. E. J., & Ren, C. L. (2009) · Lab on a Chip · doi:10.1039/b911412m · Cited by 63
Flexible casting of modular self-aligning microfluidic assembly blocks
Langelier, S. M., Livak-Dahl, E., Manzo, A. J., Johnson, B. N., Walter, N. G., & Burns, M. A. (2011) · Lab on a Chip · doi:10.1039/c0lc00517g · Cited by 62
Cell Adhesion and Growth to Peptide-Patterned Supported Lipid Membranes
Stroumpoulis, D., Zhang, H., Rubalcava, L., Gliem, J., & Tirrell, M. (2007) · Langmuir · doi:10.1021/la062375p · Cited by 60
Droplet actuation on a liquid layer due to thermocapillary motion: Shape effect
Yakhshi-Tafti, E., Cho, H. J., & Kumar, R. (2010) · Applied Physics Letters · doi:10.1063/1.3456391 · Cited by 60
Saïas, L., Autebert, J., Malaquin, L., & Viovy, J. (2011) · Lab on a Chip · doi:10.1039/c0lc00304b · Cited by 59
Systematic modeling of microfluidic concentration gradient generators
Wang, Y., Mukherjee, T., & Lin, Q. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/10/029 · Cited by 59
Hattori, K., Sugiura, S., & Kanamori, T. (2009) · Lab on a Chip · doi:10.1039/b816995k · Cited by 58
Microfluidic Device with Chemical Gradient for Single-Cell Cytotoxicity Assays
Hosokawa, M., Hayashi, T., Mori, T., Yoshino, T., Nakasono, S., & Matsunaga, T. (2011) · Analytical Chemistry · doi:10.1021/ac2000225 · Cited by 56
Solder-based chip-to-tube and chip-to-chip packaging for microfluidic devices
Murphy, E. R., Inoue, T., Sahoo, H. R., Zaborenko, N., & Jensen, K. F. (2007) · Lab on a Chip · doi:10.1039/b704804a · Cited by 54
Li, C., Chen, R., & Yang, M. (2007) · Lab on a Chip · doi:10.1039/b705525k · Cited by 52
Branched vascular network architecture: A new approach to lung assist device technology
Hoganson, D. M., Anderson, J. L., Weinberg, E. J., Swart, E. F., Orrick, B. K., Borenstein, J. T., & Vacanti, J. P. (2010) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2010.02.062 · Cited by 49
Integrated microfluidic devices for combinatorial cell-based assays
Yu, Z. T. F., Kamei, K., Takahashi, H., Shu, C. J., Wang, X., He, G. W., Silverman, R. W., Radu, C. G., Witte, O. N., Lee, K., et al. (2009) · Biomedical Microdevices · doi:10.1007/s10544-008-9260-x · Cited by 47
Self-citationGutierrez, E., & Groisman, A. (2007) · Analytical Chemistry · doi:10.1021/ac061703n · Cited by 47
Millisecond treatment of cells using microfluidic devices via two-step carrier-medium exchange
Yamada, M., Kobayashi, J., Yamato, M., Seki, M., & Okano, T. (2008) · Lab on a Chip · doi:10.1039/b718281c · Cited by 47
A microfluidic gradient maker for toxicity testing of bupivacaine and lidocaine
Tirella, A., Marano, M., Vozzi, F., & Ahluwalia, A. D. (2008) · Toxicology in Vitro · doi:10.1016/j.tiv.2008.09.016 · Cited by 45
DNA methylation analysis on a droplet-in-oil PCR array
Zhang, Y., Bailey, V. J., Puleo, C., Easwaran, H., Griffiths, E. A., Herman, J. G., Baylin, S. B., & Wang, T. (2009) · Lab on a Chip · doi:10.1039/b821780g · Cited by 45
Parallel microfluidic networks for studying cellular response to chemical modulation
Liu, D., Wang, L., Zhong, R., Li, B., Ye, N., Liu, X., & Lin, B. (2007) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2007.06.014 · Cited by 43
Strategies for the discovery of new catalysts with combinatorial chemistry
Kirsten, G., & Maier, W. F. (2003) · Applied Surface Science · doi:10.1016/s0169-4332(03)00911-5 · Cited by 43
Chen, A., & Pan, T. (2010) · Lab on a Chip · doi:10.1039/c0lc00384k · Cited by 36
Microenvironment array chip for cell culture environment screening
Hattori, K., Sugiura, S., & Kanamori, T. (2010) · Lab on a Chip · doi:10.1039/c0lc00390e · Cited by 35
Agent-based simulations of complex droplet pattern formation in a two-branch microfluidic network
Smith, B. J., & Gaver, D. P. (2009) · Lab on a Chip · doi:10.1039/b916380h · Cited by 32
Characterization of transport in microfluidic gradient generators
Gorman, B. R., & Wikswo, J. P. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0169-0 · Cited by 31
Kim, T., & Cho, Y.-H. (2011) · Lab on a Chip · doi:10.1039/c1lc20234k · Cited by 31
Manipulation of Spherical Droplets on a Liquid Platform Using Thermal GradientsPreprint
Yakhshi-Tafti, E., Cho, H. J., & Kumar, R. (2010) · arXiv (Cornell University) · doi:10.48550/arxiv.1010.3283 · Cited by 30
Comparison of Inlet Geometry in Microfluidic Cell Affinity Chromatography
Li, P., Tian, Y. P., & Pappas, D. (2011) · Analytical Chemistry · doi:10.1021/ac102975g · Cited by 30
Generation of dynamic chemical signals with microfluidic C-DACs
Chen, L. E., Azizi, F., & Mastrangelo, C. H. (2007) · Lab on a Chip · doi:10.1039/b706304k · Cited by 28
System-level simulation of liquid filling in microfluidic chips
Song, H., Wang, Y., & Pant, K. (2011) · Biomicrofluidics · doi:10.1063/1.3589843 · Cited by 28
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Active and passive micromixers: A comprehensive review
Bayareh, M., Ashani, M. N., & Usefian, A. (2020) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2019.107771 · Cited by 500
Electronics-free pneumatic circuits for controlling soft-legged robots
Drotman, D., Jadhav, S., Sharp, D., Chan, C., & Tolley, M. T. (2021) · Science Robotics · doi:10.1126/scirobotics.aay2627 · Cited by 430
3D printing: an emerging tool for novel microfluidics and lab-on-a-chip applications
Yazdi, A. A., Popma, A., Wong, W., Nguyen, T., Pan, Y., & Xu, J. (2016) · Microfluidics and Nanofluidics · doi:10.1007/s10404-016-1715-4 · Cited by 307
Discrete elements for 3D microfluidics
Bhargava, K. C., Thompson, B., & Malmstadt, N. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1414764111 · Cited by 298
Metadata
- Authors
- Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 3
- Pages
- 515-545
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2140974583
- Cited by
- 685
- References
- 210
- FWCI
- 12.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.