Spinning magnetic trap for automated microfluidic assay systems
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
While sophisticated analyses have been performed using lab-on-chip devices, in most cases the sample preparation is still performed off chip. The global need for easy-to-use, disposable testing devices necessitates that sample processing is automated and that transport complexity between the processing and analytical components is minimal. We describe a complete sample manipulation unit for performing automated target capture, efficient mixing with reagents, and controlled target release in a microfluidic channel, using an array of spinning magnets. The "MagTrap" device consists of 6 pairs of magnets in a rotating wheel, situated immediately beneath the microchannel. Rotation of the wheel in the direction opposite to the continuous flow entraps and concentrates the bead-target complexes and separates them from the original sample matrix. As the wheel rotates and the active pair of magnets moves away from the microchannel, the beads are released and briefly flow downstream before being trapped and pulled upstream by the next pair of magnets. This dynamic and continuous movement of the beads ensures that the full surface area of each bead is exposed to reagents and prevents aggregation. The release of the target-bead complexes for further analysis is facilitated by reversing the rotational direction of the wheel to sweep the beads downstream. Sample processing with the MagTrap was demonstrated for the detection of E. coli in a range of concentrations (1 × 10(3), 1 × 10(4) and 1 × 10(6) cells ml(-1)). Results show that sample processing with the MagTrap outperformed the standard manual protocols, improving the detection capability while simultaneously reducing the processing time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“There are some challenges for microfluidic magnetic separation platforms due to the magnetic beads aggregated in a microchannel using a fixed magnet.23 The aggregation of magnetic beads is not fully exposed to the reagent and affects the flow of the microchannel fluid, which results in the reduction of the efficiency of cell separation.”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [23]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Continuous sorting of magnetic cells via on-chip free-flow magnetophoresis
Pamme, N., & Wilhelm, C. (2006) · Lab on a Chip · doi:10.1039/b604542a · Cited by 497
On-Chip Free-Flow Magnetophoresis: Continuous Flow Separation of Magnetic Particles and Agglomerates
Pamme, N., & Manz, A. (2004) · Analytical Chemistry · doi:10.1021/ac049183o · Cited by 475
Biomedical applications of distally controlled magnetic nanoparticles
Corchero, J. L., & Villaverde, A. (2009) · Trends in Biotechnology · doi:10.1016/j.tibtech.2009.04.003 · Cited by 281
Sung Kim, K., & Park, J.-K. (2005) · Lab on a Chip · doi:10.1039/b502225h · Cited by 217
Multi-wavelength microflow cytometer using groove-generated sheath flow
Golden, J. P., Kim, J. S., Erickson, J. S., Hilliard, L. R., Howell, P. B., Anderson, G. P., Nasir, M., & Ligler, F. S. (2009) · Lab on a Chip · doi:10.1039/b822442k · Cited by 159
Self-citationSample preconcentration in microfluidic devices
Lin, C.-C., Hsu, J., & Lee, G. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0661-9 · Cited by 145
SISCAPA Peptide Enrichment on Magnetic Beads Using an In-line Bead Trap Device
Anderson, N. L., Jackson, A., Smith, D., Hardie, D., Borchers, C., & Pearson, T. W. (2009) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800446-mcp200 · Cited by 141
Multiplexed Detection of Bacteria and Toxins Using a Microflow Cytometer
Kim, J. S., Anderson, G. P., Erickson, J. S., Golden, J. P., Nasir, M., & Ligler, F. S. (2009) · Analytical Chemistry · doi:10.1021/ac9005827 · Cited by 108
Self-citationMobile magnetic particles as solid-supports for rapid surface-based bioanalysis in continuous flow
Peyman, S. A., Iles, A., & Pamme, N. (2009) · Lab on a Chip · doi:10.1039/b904724g · Cited by 99
Research works printed but not linked: 3
- Memisevic J Shriver-Lake LC Howell PB Golden JP Hashemi N Jackson KB Ligler FS BioPhotonics 2011 1 3 2011 International Workshop on, IEEE
- Taitt CR Shriver-Lake LC Anderson GP Ligler FS Hurst SJJ Biomedical Nanotechnology 2011 vol. 726 77 94 Humana Press
- Corporation L xMAP Technology Technical Note 2010
Cited by
Sulfur and Its Role In Modern Materials Science
Boyd, D. A. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201604615 · Cited by 512
Lab on a chip for continuous-flow magnetic cell separation
Hejazian, M., Li, W., & Nguyen, N.-T. (2015) · Lab on a Chip · doi:10.1039/c4lc01422g · Cited by 347
Microfluidics Based Magnetophoresis: A Review
Alnaimat, F., Dagher, S., Mathew, B., Hilal‐Alnqbi, A., & Khashan, S. (2018) · The Chemical Record · doi:10.1002/tcr.201800018 · Cited by 166
Recent advances and current challenges in magnetophoresis based micro magnetofluidics
Munaz, A., Shiddiky, M. J. A., & Nguyen, N.-T. (2018) · Biomicrofluidics · doi:10.1063/1.5035388 · Cited by 164
Recent advances in manipulation of micro- and nano-objects with magnetic fields at small scales
Cao, Q., Fan, Q., Chen, Q., Liu, C., Han, X., & Li, L. (2019) · Materials Horizons · doi:10.1039/c9mh00714h · Cited by 160
Advances in microfluidic devices made from thermoplastics used in cell biology and analyses
Gencturk, E., Mutlu, S., & Ülgen, K. Ö. (2017) · Biomicrofluidics · doi:10.1063/1.4998604 · Cited by 145
Universal electronics for miniature and automated chemical assays
Urban, P. L. (2014) · The Analyst · doi:10.1039/c4an02013h · Cited by 88
Elevating Chemistry Research with a Modern Electronics Toolkit
Prabhu, G. R. D., & Urban, P. L. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00206 · Cited by 92
Microfluidic bio-particle manipulation for biotechnology
Çetin, B., Özer, M. B., & Solmaz, M. E. (2014) · Biochemical Engineering Journal · doi:10.1016/j.bej.2014.07.013 · Cited by 94
“Most transparent materials such as glass, fused silica, PDMS, PMMA are suitable owing to their transparency to visible and near-infrared spectrum.”
InfluentialMedina, D. A. V., Cabal, L. F. R., Lanças, F. M., & Santos‐Neto, Á. J. (2019) · HardwareX · doi:10.1016/j.ohx.2019.e00056 · Cited by 59
Microfluidic chips with reversed-phase monoliths for solid phase extraction and on-chip labeling
Nge, P. N., Pagaduan, J. V., Yu, M., & Woolley, A. T. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.08.095 · Cited by 54
Schwefel in der modernen Materialwissenschaft
Boyd, D. A. (2016) · Angewandte Chemie · doi:10.1002/ange.201604615 · Cited by 52
Signal amplification strategies for microfluidic immunoassays
Giri, B., Pandey, B., Neupane, B. B., & Ligler, F. S. (2015) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.021 · Cited by 54
Self-citationCatch and Release: Integrated System for Multiplexed Detection of Bacteria
Verbarg, J. M., Plath, W., Shriver‐Lake, L. C., Howell, P. B., Erickson, J. S., Golden, J. P., & Ligler, F. S. (2013) · Analytical Chemistry · doi:10.1021/ac303801v · Cited by 39
Self-citationYoo, J. J., Anderson, M. J., Alligrant, T. M., & Crooks, R. M. (2014) · Analytical Chemistry · doi:10.1021/ac404093c · Cited by 39
Verbarg, J. M., Hadass, O., Olivo, P. D., & Danielli, A. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.10.089 · Cited by 34
Self-citationRecent advances in controlled manipulation of micro/nano particles: a review
Shah, M., Wu, Y., Chen, S., Mead, J. L., Hou, L., Liu, K., Tao, S., Fatikow, S., & Wang, S. (2024) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ad9030 · Cited by 33
“Verbarg et al developed a system involving a spinning magnet array, termed the MagTrap, for on-chip sample processing, as shown in figure 11(a) [187].”
Yang, R., Pagaduan, J. V., Yu, M., & Woolley, A. T. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7988-0 · Cited by 34
Xue, M., Xiang, A., Guo, Y., Wang, L., Wang, R., Wang, W., Ji, G., & Lu, Z. (2019) · RSC Advances · doi:10.1039/c9ra08285a · Cited by 26
Industry applications of magnetic separation based on nanoparticles: A review
Wang, Z., Liu, C., & Wei, W. (2019) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-180087 · Cited by 26
Golden, J. P., Verbarg, J. M., Howell, P. B., Shriver‐Lake, L. C., & Ligler, F. S. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.08.015 · Cited by 24
“…under the channel pull the microspheres (including those with captured target) upstream against the flow and side-to-side in the channel to both collect and concentrate the microspheres as the sample is introduced, and to expose the microspheres sequentially to the reagents (Verbarg et al., 2012).”
Self-citationMagnetic actuator for the control and mixing of magnetic bead-based reactions on-chip
Berenguel‐Alonso, M., Granados, X., Faraudo, J., Alonso, J., & Puyol, M. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-8100-5 · Cited by 24
Magnetophoresis and Microfluidics: A Great Union
Alnaimat, F., Karam, S. M., Mathew, B. T., & Mathew, B. (2020) · IEEE Nanotechnology Magazine · doi:10.1109/mnano.2020.2966029 · Cited by 24
“[22] devised a novel arrangement involving rotating external permanent magnets for realizing time-varying magnetophoresis inside the microchannel [Figure 2(d)].”
Golozar, M., Molki, M., & Darabi, J. (2017) · Microfluidics and Nanofluidics · doi:10.1007/s10404-017-1909-4 · Cited by 22
“…biological entities (Xia et al. 2006; Liu et al. 2007; Jung and Han 2008; Adams et al. 2008; Derec et al. 2010; Lee et al. 2010; Shen et al. 2012; Verbarg et al. 2012; Jung et al. 2010; Khashan et al. 2014; Pamme and Wilhelm 2006; Forbes and Forry 2012; Zeng et al. 2013; Liang et al. 2013;…”
Development of a PMMA Electrochemical Microfluidic Device for Carcinoembryonic Antigen Detection
Anh, N. V., Trung, H. V., Tien, B. Q., Nguyen, H. B., Cao, H., Huy, N. L., Nguyen, L. T., Thu, V. T., & Лам, Т. Д. (2016) · Journal of Electronic Materials · doi:10.1007/s11664-016-4372-1 · Cited by 20
Benhal, P., Broda, A., Najafali, D., Malik, P., Mohammed, A. M., Ramaswamy, B., Depireux, D. A., Shimoji, M., Shukoor, M. I., & Shapiro, B. (2018) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2018.10.148 · Cited by 17
Magnetic Field-Based Technologies for Lab-on-a-Chip Applications
Iacovacci, V., Lucarini, G., Ricotti, L., & Menciassi, A. (2016) · InTech eBooks · doi:10.5772/62865 · Cited by 20
“Alternatively, permanent magnets can be actuated to generate a time-dependent magnetic field, for example, through the use of a rotating magnetic wheel [23], or arranged in an asymmetric configuration, thus generating spatial field variation or multiple magnetic separation stages [24].”
Design and operation of magnetophoretic systems at microscale: Device and particle approaches
Chong, W. H., Leong, S. S., & Lim, J. (2021) · Electrophoresis · doi:10.1002/elps.202100081 · Cited by 16
Sonker, M., Yang, R., Sahore, V., Kumar, S., & Woolley, A. T. (2016) · Analytical Methods · doi:10.1039/c6ay01803c · Cited by 14
Jussen, D., Soltner, H., Stute, B., Wiechert, W., von Lieres, E., & Pohl, M. (2016) · Journal of Biotechnology · doi:10.1016/j.jbiotec.2016.06.006 · Cited by 13
High-Resolution Micro-object Separation by Rotating Magnetic Chromatography
Piao, J., Liu, L., Cai, L., Ri, H. C., Jin, X., Sun, H., Piao, X., Shang, H., Jin, X., Pu, Q., et al. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c01385 · Cited by 6
Flow cytometry and pathogen screening in foods
Taitt, C. R., & North, S. H. (2014) · Elsevier eBooks · doi:10.1016/b978-0-85709-801-6.00008-3 · Cited by 6
Research Advances in Magnetophoretic Separation: Fundamentals and Methodologies
Shao, L., Feng, Z., Du, Q., Zou, G., & Tan, Z. (2024) · Separation and Purification Reviews · doi:10.1080/15422119.2024.2439957 · Cited by 5
“[111] Verbarg et al. [112] used an array of spinning magnets, in which permanent magnets were positioned on a rotating wheel beneath a channel.”
Dai, J., Li, W., Gong, B., Wang, H., Xia, M., & Yang, K. (2015) · Optics Express · doi:10.1364/oe.23.030204 · Cited by 4
Cell Concentration Systems for Enhanced Biosensor Sensitivity
Castillo‐Fernández, Ó., Uría, N., Muñoz, F. X., & Bratov, A. V. (2015) · InTech eBooks · doi:10.5772/61088 · Cited by 4
Liu, X., Wang, X., Wu, X., Zhang, Z., & Zhang, Y. (2013) · Microsystem Technologies · doi:10.1007/s00542-013-1897-6 · Cited by 3
“Firstly, since magnets need to be individually fabricated, further miniaturization of multiplexing would be complicated (Verbarg et al. 2012; Xia et al. 2006).”
Reconfigurable acquisition system with integrated optics for a portable flow cytometer
Kirleis, M. A., Mathews, S. A., Verbarg, J. M., Erickson, J. S., & Piqué, A. (2013) · Review of Scientific Instruments · doi:10.1063/1.4831835 · Cited by 1
Self-citationBruno, J. G., & Phillips, T. (2016) · Journal of Biomedical Engineering and Medical Devices · doi:10.4172/2475-7586.1000103 · Cited by 1
“More complex external and internal magnetic pumping systems [34-36] including the rotating magnetic wheel pump developed at the Naval Research Laboratories [37] are ingenious and highly useful, but we sought the simplest possible and least expensive system which would still enable the concentrating and purifying advan…”
Medina, D. A. V. (2019) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.75.2019.tde-06022019-163042 · Cited by 4
Metadata
- Authors
- Verbarg, J., Kamgar-Parsi, K., Shields, A. R., Howell, P. B., & Ligler, F. S.
- Affiliations
- United States Naval Research Laboratory (US)
- Corresponding author
- Ligler, Frances S.
- ORCID
- Ligler, Frances S.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 10
- Pages
- 1793
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- PMC
- PMC3641145
- OpenAlex
- W2066940483
- Cited by
- 39
- References
- 27
- Citations by year
- 2024: 2 · 2022: 1 · 2021: 1 · 2020: 2 · 2019: 5 · 2018: 3 · 2017: 2 · 2016: 8 · 2015: 3 · 2014: 7 · 2013: 3 · 2012: 2
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- Defense Threat Reduction Agency
- U.S. Public Health Service (U01 A1075489)
- U.S. Navy
- Office of Naval Research
- National Institute of Allergy and Infectious Diseases (U01AI075489)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Keywords
- automated sample preparation, Escherichia coli detection, lab-on-a-chip
- MeSH terms
- Equipment Design, Escherichia coli, Fluorescent Dyes, Immunoglobulin G, Immunoassay, Microspheres, Models, Theoretical, Immunomagnetic Separation, Microfluidic Analytical Techniques, Magnets
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.