Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 163

The DOI matches its Crossref record.

A programmable microfluidic cell array for combinatorial drug screening

Open access
Kim, Jeongyun, Taylor, David, Agrawal, Nitin, Wang, Han, Kim, Hyunsoo, Han, Arum, Rege, Kaushal, Jayaraman, Arul·2012·Lab on a Chip

Abstract

We describe the development of a fully automatic and programmable microfluidic cell culture array that integrates on-chip generation of drug concentrations and pair-wise combinations with parallel culture of cells for drug candidate screening applications. The device has 64 individually addressable cell culture chambers in which cells can be cultured and exposed either sequentially or simultaneously to 64 pair-wise concentration combinations of two drugs. For sequential exposure, a simple microfluidic diffusive mixer is used to generate different concentrations of drugs from two inputs. For generation of 64 pair-wise combinations from two drug inputs, a novel time dependent variable concentration scheme is used in conjunction with the simple diffusive mixer to generate the desired combinations without the need for complex multi-layer structures or continuous medium perfusion. The generation of drug combinations and exposure to specific cell culture chambers are controlled using a LabVIEW interface capable of automatically running a multi-day drug screening experiment. Our cell array does not require continuous perfusion for keeping cells exposed to concentration gradients, minimizing the amount of drug used per experiment, and cells cultured in the chamber are not exposed to significant shear stress continuously. The utility of this platform is demonstrated for inducing loss of viability of PC3 prostate cancer cells using combinations of either doxorubicin or mitoxantrone with TRAIL (TNF-alpha Related Apoptosis Inducing Ligand) either in a sequential or simultaneous format. Our results demonstrate that the device can capture the synergy between different sensitizer drugs and TRAIL and demonstrate the potential of the microfluidic cell array for screening and optimizing combinatorial drug treatments for cancer therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c2lc21202a

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 35

  1. Beltran, 2011, Eur. Urol., 60, 279, 10.1016/j.eururo.2011.04.038 · DOI · Paper page
  2. Zhang, 2005, Cancer Gene Ther., 12, 228, 10.1038/sj.cgt.7700792 · DOI · Paper page
  3. Sheikh, 2000, J. Cell. Physiol., 182, 171, 10.1002/(SICI)1097-4652(200002)182:2<171::AID-JCP5>3.0.CO;2-3 · DOI · Paper page
  4. Bouralexis, 2005, Apoptosis, 10, 35, 10.1007/s10495-005-6060-0 · DOI
  5. Kelley, 2004, Curr. Opin. Pharmacol., 4, 333, 10.1016/j.coph.2004.02.006 · DOI · Paper page
  6. Naka, 2002, Cancer Res., 62, 5800
  7. Singh, 2003, Cancer Res., 63, 5390
  8. Shankar, 2004, Prostate, 61, 35, 10.1002/pros.20069 · DOI
  9. Ohtsuka, 2003, Oncogene, 22, 1678, 10.1038/sj.onc.1206306 · DOI
  10. Barua, 2010, Cancer Lett., 293, 240, 10.1016/j.canlet.2010.01.012 · doi:10.1016/j.canlet.2010.01.012
  11. Sun, 2000, Cancer Res., 60, 7149
  12. El-Zawahry, 2005, BMC Cancer, 5, 2, 10.1186/1471-2407-5-2 · DOI
  13. Kelly, 2002, Cancer Biol. Ther., 1, 520, 10.4161/cbt.1.5.174 · DOI
  14. Taylor, 2011, BMC Cancer, 11, 470, 10.1186/1471-2407-11-470 · doi:10.1186/1471-2407-11-470
  15. Ohgami, 2010, Cancer Sci., 101, 1387, 10.1111/j.1349-7006.2010.01543.x · DOI
  16. Booth, 2009, Cancer Immunol. Immunother., 58, 1229, 10.1007/s00262-008-0637-8 · DOI
  17. Sugiura, 2008, Biotechnol. Bioeng., 100, 1156, 10.1002/bit.21836 · DOI
  18. Wu, 2010, Lab Chip, 10, 939, 10.1039/b921695b · DOI · Paper page
  19. Lee, 2006, Biotechnol. Bioeng., 94, 5, 10.1002/bit.20745 · DOI · Paper page
  20. Thompson, 2004, Anal. Chem., 76, 4098, 10.1021/ac0354241 · DOI · Paper page
  21. King, 2007, Lab Chip, 7, 77, 10.1039/B612516F · DOI · Paper page
  22. Wieder, 2005, Biomed. Microdevices, 7, 213, 10.1007/s10544-005-3028-3 · DOI
  23. Neils, 2004, Lab Chip, 4, 342, 10.1039/B314962E · DOI
  24. Jang, 2011, Lab Chip, 11, 3277, 10.1039/c1lc20449a · DOI
  25. Whitesides, 2001, Annu. Rev. Biomed. Eng., 3, 335, 10.1146/annurev.bioeng.3.1.335 · DOI · Paper page
  26. Kim, 2010, J. Visualized Exp., 38, e1749
  27. Odom, 2002, Langmuir, 18, 5314, 10.1021/la020169l · DOI · Paper page
  28. Grover, 2003, Sens. Actuators, B, 89, 315, 10.1016/S0925-4005(02)00468-9 · DOI · Paper page
  29. Jeon, 2002, Biomed. Microdevices, 4, 117, 10.1023/A:1014683114796 · DOI
  30. Jeon, 2002, Nat. Biotechnol., 20, 826, 10.1038/nbt712 · DOI · Paper page
  31. Neils, 2004, Lab Chip, 4, 342, 10.1039/B314962E · DOI
  32. Gómez-Sjöberg, 2007, Anal. Chem., 79, 8557, 10.1021/ac071311w · DOI · Paper page
  33. Walkers, 2002, Biomed. Microdevices, 4, 161, 10.1023/A:1016088128057 · DOI
  34. Toepke, 2006, Lab Chip, 6, 1484, 10.1039/b612140c · DOI · Paper page
  35. Ostuni, 2001, Langmuir, 17, 2828, 10.1021/la001372o · DOI · Paper page

Cited by

See all 163

Metadata

Authors
Kim, J., Taylor, D., Agrawal, N., Wang, H., Kim, H., Han, A., Rege, K., & Jayaraman, A.
Venue
Lab on a Chip
Published
2012
Volume
12
Issue
10
Pages
1813
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2104645521
Cited by
163
References
0
FWCI
6.98
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A programmable microfluidic cell array for combinatorial drug screening. https://app.cochat.ai/papers/10.1039/c2lc21202a
The paper
Kim, J., Taylor, D., Agrawal, N., Wang, H., Kim, H., Han, A., Rege, K., & Jayaraman, A. (2012). A programmable microfluidic cell array for combinatorial drug screening. Lab on a Chip. https://doi.org/10.1039/c2lc21202a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.