The DOI matches its Crossref record.
A programmable microfluidic cell array for combinatorial drug screening
Open accessAbstract
We describe the development of a fully automatic and programmable microfluidic cell culture array that integrates on-chip generation of drug concentrations and pair-wise combinations with parallel culture of cells for drug candidate screening applications. The device has 64 individually addressable cell culture chambers in which cells can be cultured and exposed either sequentially or simultaneously to 64 pair-wise concentration combinations of two drugs. For sequential exposure, a simple microfluidic diffusive mixer is used to generate different concentrations of drugs from two inputs. For generation of 64 pair-wise combinations from two drug inputs, a novel time dependent variable concentration scheme is used in conjunction with the simple diffusive mixer to generate the desired combinations without the need for complex multi-layer structures or continuous medium perfusion. The generation of drug combinations and exposure to specific cell culture chambers are controlled using a LabVIEW interface capable of automatically running a multi-day drug screening experiment. Our cell array does not require continuous perfusion for keeping cells exposed to concentration gradients, minimizing the amount of drug used per experiment, and cells cultured in the chamber are not exposed to significant shear stress continuously. The utility of this platform is demonstrated for inducing loss of viability of PC3 prostate cancer cells using combinations of either doxorubicin or mitoxantrone with TRAIL (TNF-alpha Related Apoptosis Inducing Ligand) either in a sequential or simultaneous format. Our results demonstrate that the device can capture the synergy between different sensitizer drugs and TRAIL and demonstrate the potential of the microfluidic cell array for screening and optimizing combinatorial drug treatments for cancer therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 35
- Beltran, 2011, Eur. Urol., 60, 279, 10.1016/j.eururo.2011.04.038 · DOI · Paper page
- Zhang, 2005, Cancer Gene Ther., 12, 228, 10.1038/sj.cgt.7700792 · DOI · Paper page
- Sheikh, 2000, J. Cell. Physiol., 182, 171, 10.1002/(SICI)1097-4652(200002)182:2<171::AID-JCP5>3.0.CO;2-3 · DOI · Paper page
- Bouralexis, 2005, Apoptosis, 10, 35, 10.1007/s10495-005-6060-0 · DOI
- Kelley, 2004, Curr. Opin. Pharmacol., 4, 333, 10.1016/j.coph.2004.02.006 · DOI · Paper page
- Naka, 2002, Cancer Res., 62, 5800
- Singh, 2003, Cancer Res., 63, 5390
- Shankar, 2004, Prostate, 61, 35, 10.1002/pros.20069 · DOI
- Ohtsuka, 2003, Oncogene, 22, 1678, 10.1038/sj.onc.1206306 · DOI
- Barua, 2010, Cancer Lett., 293, 240, 10.1016/j.canlet.2010.01.012 · doi:10.1016/j.canlet.2010.01.012
- Sun, 2000, Cancer Res., 60, 7149
- El-Zawahry, 2005, BMC Cancer, 5, 2, 10.1186/1471-2407-5-2 · DOI
- Kelly, 2002, Cancer Biol. Ther., 1, 520, 10.4161/cbt.1.5.174 · DOI
- Taylor, 2011, BMC Cancer, 11, 470, 10.1186/1471-2407-11-470 · doi:10.1186/1471-2407-11-470
- Ohgami, 2010, Cancer Sci., 101, 1387, 10.1111/j.1349-7006.2010.01543.x · DOI
- Booth, 2009, Cancer Immunol. Immunother., 58, 1229, 10.1007/s00262-008-0637-8 · DOI
- Sugiura, 2008, Biotechnol. Bioeng., 100, 1156, 10.1002/bit.21836 · DOI
- Wu, 2010, Lab Chip, 10, 939, 10.1039/b921695b · DOI · Paper page
- Lee, 2006, Biotechnol. Bioeng., 94, 5, 10.1002/bit.20745 · DOI · Paper page
- Thompson, 2004, Anal. Chem., 76, 4098, 10.1021/ac0354241 · DOI · Paper page
- King, 2007, Lab Chip, 7, 77, 10.1039/B612516F · DOI · Paper page
- Wieder, 2005, Biomed. Microdevices, 7, 213, 10.1007/s10544-005-3028-3 · DOI
- Neils, 2004, Lab Chip, 4, 342, 10.1039/B314962E · DOI
- Jang, 2011, Lab Chip, 11, 3277, 10.1039/c1lc20449a · DOI
- Whitesides, 2001, Annu. Rev. Biomed. Eng., 3, 335, 10.1146/annurev.bioeng.3.1.335 · DOI · Paper page
- Kim, 2010, J. Visualized Exp., 38, e1749
- Odom, 2002, Langmuir, 18, 5314, 10.1021/la020169l · DOI · Paper page
- Grover, 2003, Sens. Actuators, B, 89, 315, 10.1016/S0925-4005(02)00468-9 · DOI · Paper page
- Jeon, 2002, Biomed. Microdevices, 4, 117, 10.1023/A:1014683114796 · DOI
- Jeon, 2002, Nat. Biotechnol., 20, 826, 10.1038/nbt712 · DOI · Paper page
- Neils, 2004, Lab Chip, 4, 342, 10.1039/B314962E · DOI
- Gómez-Sjöberg, 2007, Anal. Chem., 79, 8557, 10.1021/ac071311w · DOI · Paper page
- Walkers, 2002, Biomed. Microdevices, 4, 161, 10.1023/A:1016088128057 · DOI
- Toepke, 2006, Lab Chip, 6, 1484, 10.1039/b612140c · DOI · Paper page
- Ostuni, 2001, Langmuir, 17, 2828, 10.1021/la001372o · DOI · Paper page
Cited by
Three-dimensional in vitro tumor models for cancer research and drug evaluation
Xu, X., Farach-Carson, M. C., & Jia, X. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.07.009 · Cited by 461
Recent Advances in Droplet Microfluidics
Ding, Y., Howes, P. D., & deMello, A. J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05047 · Cited by 357
An outlook on microfluidics: the promise and the challenge
Battat, S., Weitz, D. A., & Whitesides, G. M. (2022) · Lab on a Chip · doi:10.1039/d1lc00731a · Cited by 333
Microfluidics for cell-based high throughput screening platforms—A review
Du, G., Fang, Q., & den Toonder, J. M. J. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.023 · Cited by 276
The Tumor Microenvironment: A Pitch for Multiple Players
Schiavoni, G., Gabriele, L., & Mattei, F. (2013) · Frontiers in Oncology · doi:10.3389/fonc.2013.00090 · Cited by 147
Metadata
- Authors
- Kim, J., Taylor, D., Agrawal, N., Wang, H., Kim, H., Han, A., Rege, K., & Jayaraman, A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 10
- Pages
- 1813
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2104645521
- Cited by
- 163
- References
- 0
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A programmable microfluidic cell array for combinatorial drug screening. https://app.cochat.ai/papers/10.1039/c2lc21202a
- The paper
- Kim, J., Taylor, D., Agrawal, N., Wang, H., Kim, H., Han, A., Rege, K., & Jayaraman, A. (2012). A programmable microfluidic cell array for combinatorial drug screening. Lab on a Chip. https://doi.org/10.1039/c2lc21202a
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.