The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A microfluidic flow-stretch chip for investigating blood vessel biomechanics
Abstract
This microfluidic flow-stretch chip integrates fluid shear stress (FSS) and cyclic stretch (CS), two major mechanical stimulations in cardiovascular systems, for cultured cells. The model chip can deliver FSS and CS simultaneously or independently to vascular cells to mimic the haemodynamic microenvironment of blood vessels in vivo. By imposing FSS-only, CS-only, and FSS+CS stimulation on rat mesenchymal stem cells and human umbilical vein endothelial cells, we found the alignment of the cellular stress fibers varied with cell type and the type of stimulation. The flow-stretch chip is a reliable tool for simulating the haemodynamic microenvironment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Douville, N. J., Zamankhan, P., Tung, Y.-C., Li, R., Vaughan, B. L., Tai, C.-F., White, J., Christensen, P. J., Grotberg, J. B., & Takayama, S. (2011) · Lab Chip · doi:10.1039/c0lc00251h · Cited by 216
Baker, M. (2011) · Nature · doi:10.1038/471661a · Cited by 188
Cited by
Microfluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272
3D Bioprinting of Vessel-like Structures with Multilevel Fluidic Channels
Gao, Q., Liu, Z., Lin, Z., Qiu, J., Liu, Y., Liu, A., Wang, Y., Xiang, M., Chen, B., Fu, J., et al. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00643 · Cited by 267
Cardiovascular disease models: A game changing paradigm in drug discovery and screening
Savoji, H., Mohammadi, M. H., Rafatian, N., Toroghi, M. K., Wang, E. Y., Zhao, Y., Korolj, A., Ahadian, S., & Radisic, M. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2018.09.036 · Cited by 223
Cardiovascular organ-on-a-chip platforms for drug discovery and development
Ribas, J., Sadeghi, H., Manbachi, A., Leijten, J., Brinegar, K., Zhang, Y. S., Ferreira, L., & Khademhosseini, A. (2016) · Applied In Vitro Toxicology · doi:10.1089/aivt.2016.0002 · Cited by 161
Flow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
Metadata
- Authors
- Zheng, W., Jiang, B., Wang, D., Zhang, W., Wang, Z., & Jiang, X.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 18
- Pages
- 3441
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2001273789
- Cited by
- 165
- References
- 3
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A microfluidic flow-stretch chip for investigating blood vessel biomechanics. https://app.cochat.ai/papers/10.1039/c2lc40173h
- The paper
- Zheng, W., Jiang, B., Wang, D., Zhang, W., Wang, Z., & Jiang, X. (2012). A microfluidic flow-stretch chip for investigating blood vessel biomechanics. Lab on a Chip. https://doi.org/10.1039/c2lc40173h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.